• 제목/요약/키워드: Deterioration assessment

검색결과 331건 처리시간 0.029초

고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

물공급시설의 노후 위험도 평가를 통한 개선 우선순위 결정 (Decision Making of Improvement Priority by Deterioration Risk Assessment of Water Supply Infrastructures)

  • 채수권;이대종;김주환
    • 환경영향평가
    • /
    • 제18권6호
    • /
    • pp.367-376
    • /
    • 2009
  • This paper proposes an application methodology of AHP(Analytic Hierarchy Process) based decision making theory for improvement priority by assessment of various risk factors affecting on deterioration of water supply systems, as major social infrastructure. AHP method is organized with three level of hierarchy which is introduced for multi-criteria decision making in this study. In the first level, assessment outputs are calculated by AHP for each affecting factor. In the second level, criteria are estimated by using assessment results with respect to structural and environmental factors. Consequently, ranking decision is performed in the third level. In order to present the effectiveness, a proposed method is compared with FCP(Fuzzy Composite Programming) for decision making. Since the results of the proposed method show better performance with consistent results, it can be applied as an efficient information for the determination for improvement priority of the study infrastructure.

Load bearing capacity reduction of concrete structures due to reinforcement corrosion

  • Chen, Hua-Peng;Nepal, Jaya
    • Structural Engineering and Mechanics
    • /
    • 제75권4호
    • /
    • pp.455-464
    • /
    • 2020
  • Reinforcement corrosion is one of the major problems in the durability of reinforced concrete structures exposed to aggressive environments. Deterioration caused by reinforcement corrosion reduces the durability and the safety margin of concrete structures, causing excessive costs in managing these structures safely. This paper aims to investigate the effects of reinforcement corrosion on the load bearing capacity deterioration of the corroded reinforced concrete structures. A new analytical method is proposed to predict the crack growth of cover concrete and evaluate the residual strength of concrete structures with corroded reinforcement failing in bond. The structural performance indicators, such as concrete crack growth and flexural strength deterioration rate, are assumed to be a stochastic process for lifetime distribution modelling of structural performance deterioration over time during the life cycle. The Weibull life evolution model is employed for analysing lifetime reliability and estimating remaining useful life of the corroded concrete structures. The results for the worked example show that the proposed approach can provide a reliable method for lifetime performance assessment of the corroded reinforced concrete structures.

전기화재에 따른 진공차단기의 건전성 평가 (A Study on the Evaluation of Reliability of the Vacuum Circuit Breaker for the Electrical Fire)

  • 최홍규;박준열
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.24-28
    • /
    • 2013
  • Fire-hited electrical equipment has possibility of deterioration. So its replacement is essential in terms of safety. However, the economic burden is increased. Therefore, the replacement or re-use of it is to be determined by tests. But the research of Integrity Assessment on Fire-hited electrical equipments is very rare. In this paper, we tested to determine the replacement or re-use of Fire-hited vacuum circuit breaker. And provided the data for the integrity assessment through the analysis of its deterioration.

상수도 관로의 물리적 상태평가 기준 개선 (Improvement of Physical Condition Assessment in Water Mains)

  • 김주환;;배철호;안효원;황진수;최두용
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.1710-1715
    • /
    • 2010
  • 상수도시설은 운영관리 환경, 사용범위, 빈도 등 특성에 따라 수명이 달라지며, 현행 법률에서 일률적으로 정하고 있는 내용연수와 차별된 접근이 필요함에 따라, 시설의 파손, 보수이력 등 관리현황 및 시설의 경시적인 변화 상태를 조사 분석하여 기술적 판단을 토대로 한 수명평가 방안이 필요하다. 따라서 본 연구에서는 국내외 내용연수 적용현황과 시설별 내용연수 산정 방안, 외국의 상수도시설물 관리 방법, 기존 관로 상태평가 기준 수립을 위한 현황 등을 조사하고, 매설 상수관로에 현장조사를 수행하여, 상수관로의 물리적인 파손위험성과 사고이력을 기반으로 경제적 가치 기준에 의한 잔존수명 평가 기법을 개발하였다. 또한 기존 우리 공사의 노후도 기법을 물리적인 노후진척에 따른 상태변화와 실측 데이터를 활용하여 통계적인 분석을 통하여 평가항목은 축소하고, 신뢰도는 제고하였으며, 관 상태평가를 통해서 합리적인 개량계획 수립을 추진할 수 있도록 관상태평가 가이드라인을 개발하였다.

  • PDF

전력케이블 열화 감시방안에 관한 연구 (A Study on Monitoring Means of Insulation deterioration of Electric Power Cable)

  • 한학수;민경윤;유기선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

Low cycle fatigue damage assessment in steel beams

  • Daali, M.L.;Korol, R.M.
    • Structural Engineering and Mechanics
    • /
    • 제3권4호
    • /
    • pp.341-358
    • /
    • 1995
  • The results of a series of ten W-shaped test specimens subjected to monotonic, quasi-static cyclic loading and fatigue type of loading in the form of constant amplitude tests are presented. The objectives were to assess and compare the rotation capacity and energy absorption of monotonically and cyclically loaded beams, and for the latter specimens to document the deterioration in the form of low cycle fatigue due to local buckling. In addition, strength and energy dissipation deterioration and damage models have been developed for the steel beam section under consideration. Finally, a generalized model which uses plate slenderness values and lateral slenderness is proposed for predicting rate in strength deterioration per reversal and cumulated damage after a given number of reversals.

경주석빙고의 정량적 훼손도 평가와 미기후환경 분석 (Quantitative Deterioration Assessment and Microclimatic Analysis of the Gyeongju Seokbinggo (Ice-storing Stone Warehouse), Korea)

  • 김지영;이찬희;이명성
    • 보존과학회지
    • /
    • 제25권1호
    • /
    • pp.25-38
    • /
    • 2009
  • 경주석빙고(보물 제66호)는 조선시대 얼음 저장고로서 주구성암석은 유백색 색조를 띠고 정동이 발달한 중립질의 알칼리화강암이다. 훼손도 평가 결과, 균열(12.5%), 이격(6.7%), 탈락(25.1%), 박락(20.9%), 백화현상(6.5%), 갈색 변색(9.8%), 암흑색 변색(2.0%) 및 생물에 의한 변색(26.5%) 등이 높은 것으로 확인되었다. 전체적인 물리적 훼손율은 43.7%로 홍예틀 1번과 2번에서, 변색에 의한 훼손율은 68.7%로 북벽에서 가장 높아 석빙고의 훼손 상태가 매우 심각한 것으로 평가되었다. 석빙고 내부는 겨울철을 제외하고 연중 90% 이상의 높은 상대습도를 유지하였으며, 내부 미기후는 외부 기후 변화에 의존하나 외부보다 변동이 현저히 적은 일정한 환경을 유지하고 있었다. 상대습도는 봄과 여름에 98~100%에 최빈값을 보였다. 훼손의 근본적인 요인은 강수와 지하수의 유입 및 결로수에 의한 높은 상대습도와 장기적인 수분 유지시간이다. 이 수분은 생물에 의한 변색, 부재의 재질약화, 구조체의 거동, 백화현상 등을 야기하였다. 한편 입구 전면의 사질토양으로 인한 분진과 부유 입자가 내부의 갈색 및 암흑색 변색을 가중시켰다.

  • PDF

휴대용 보일러튜브 건전성 평가시스템 개발 (Development of Portable Boiler Tube Health Evaluation System)

  • 이창민;이한상;김범신
    • 산업경영시스템학회지
    • /
    • 제46권3호
    • /
    • pp.101-108
    • /
    • 2023
  • Although the proportion of coal-fired power generation is decreasing, efficient operating technology is needed to continuously invest in facilities and reduce maintenance costs until it is abolished. Boilers, one of the main facilities of power plants, operate for a long time in harsh environments of high temperature and high pressure. In addition, damage due to deterioration is likely to occur depending on the fuel and tube material used. It is very important to judge soundness because damage caused by deterioration adversely affects facility operation. Previously, replication method was used to analyze the progress of deterioration. In the replication method, pre-treatment such as chemical treatment is performed on the boiler tube in the field, the area is reproduced by attaching a film, and the replicated film is determined by an expert in the laboratory with an expensive microscope. However, this method involves substantial costs and time requirements, as well as the possibility of human errors. To address these issues, we developed a mobile health assessment system in this research. Since it is detachable and takes images in real time, this system enables swift evaluations across a broad range and facilitates the assessment of preprocessing quality. In addition, it was intended to reduce existing human mistakes by developing a degradation classification algorithm using the merger cluster method.

애자 표면열화에 의한 방전특성과 ICP-AES 분석 (The discharge characteristics and ICP-AES analysis of insulators by surface deterioration)

  • 송길목;김영석;정진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1408_1409
    • /
    • 2009
  • It's described the discharge characteristics and ICP-AES analysis of insulators by surface deterioration in this paper. For the assessment of insulators, there are applied the conductivity of dusts, contact angle measurement of the insulator surfaces and the ingredient analysis in each area. Through the analysis of pollutants attached to insulators inside the tunnel, the cleaning cycle is discussed. As the results, it would be expected to the electrical safety.

  • PDF