• Title/Summary/Keyword: Detention Time

Search Result 105, Processing Time 0.02 seconds

An Analysis of a Porous Film Containing $Chamaecyparis$ $obtusa$ Extract (편백나무 추출물을 함유한 다공성 필름 분석)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.4
    • /
    • pp.551-558
    • /
    • 2011
  • This present study was performed to analyze the efficiency and volatility of a porous film containing $Chamaecyparis$ $obtusa$ extract as a method to effectively package food compounds. Phytoncide was contacted the state of gas and showed effective antimicrobial properties. Limonene can be distilled without decomposition as a relatively stable terpene and was one of the extract components. $Chamaecyparis$ $obtusa$ essential oil. The optimal solvent composition was a ratio 5:20:0.3 of T-500:ethanol:hardener to effectively manufacture film containing phytoncide essential oil and the minimum antibacterial concentration was 2%. The films were made under different conditions(A-50LF1, A-25SF2, B-50SF1, C-50LF1, C-25SF2 and D-50SF1) containing phytoncide and the amounts of limonene inside the 1-L reaction chamber depending on storage were measured by gas chromatography-mass selective detention. The results showed that the 25SF2(width, 25 mm; length, 20 cm) revealed more amount of limonene compared with 50LF1(width 50 mm, length 20 cm). We confirmed that the gas emission amount showed a better layer on the film side than on the internal film. An effect of film thickness on phytoncide emissions was observed in that the amounts was less than the expectation for a thicker film at the beginning time, but the emitting amounts increased with increasing storage periods. In the storage testing of various films at $35^{\circ}C$ and 70% humidity for 14 days, 25SF2 showed longer preservation compared with that of 50LF in the case of bread. $C.$ $obtusa$ essential oil is a useful fresh ingredients, hence, analysis of limonene emission kinetics from various film was helpful to develop films with an optimal antimicrobial effect, and will allow application of such films in food packaging systems.

Effect on Digestion Efficiency by Adding Microbial Agent in Mesophilic Two-stage Anaerobic Digester (중온2단혐기성소화조에 미생물제재 주입시 소화효율에 미치는 영향)

  • Jung, Byung-Gil;Kim, Seok-Soon;Kang, Dong-Hyo;Sung, Nak-Chang;Choi, Seung-Ho;Lee, Hee-Pom
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.3
    • /
    • pp.75-86
    • /
    • 2003
  • In the near future, the capacity of conventional anaerobic digester is thought to be insufficient because of the increase of the total solids from expansion of intercepting sewer, sewage quantity and direct input of night soil from near apartment districts. The objectives of this study was to investigate the improvement of digestion efficiency using microbial agent(Bio-dh). The system was a pilot-scale, two-staged, anaerobic sludge digestion system. The first-stage digester was heated and mixed. The agitation velocity of the first-stage digester was 120rpm. The second-stage digester was neither heated nor mixed. The Digestion temperature was kept at $35{\pm}1^{\circ}C$ The detention time of digester was 19 days. The dosage of sewage sludge and microbial agent were $0.65m^3/day$ and $0.5{\ell}/day$, respectively. The experiments was run for 25days. Three times a week, $COD_{Mn}$ and SS of effluent, TS, VS, and biogas production rate were measured. Temperature, pH, and alkalinity were measured daily. The results were as follows ; Without microbial agent, digestion efficiencies ranged 46.0%~50.9%(mean=48.6%), with microbial agent(Bio-dh), digestion efficiencies ranged 52.8%~57.3%(mean=54.2%). Consequently, microbial agent(Bio-dh) increased the sludge digestion efficiency about 12%. Also, Without microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 1,639mg/L, 4,888mg/L respectively. With microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 859mg/L, 2,405mg/L respectively. Consequently, microbial agent(Bio-dh) increased the removal efficiency of $COD_{Mn}$ and SS about 47.6% and 50.8%, respectively.

  • PDF

Treatment Level of a Pond System for Ecological Treatment and Recycling of Animal Excreta (생태적 축산폐수 처리 및 재활용 연못시스템의 폐수처리수준)

  • Yang, Hong-Mo;Rhee, Chong-Ouk
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.70-75
    • /
    • 1998
  • A model of pond system is developed for treatment and recycling of excreta from twenty-five adult dairy cattle. It is composed of wastewater treatment ponds and small fish ponds. Those are three facultative ponds in series; primary-secondary-tertiary pond and these are designed to rear carps without feeding. A pit is constructed at the bottom of primary pond for efficient sludge sedimentation and effective methane fermentation. It is contrived to block into it the penetration of oxygen dissolved in the upper layer of pond water. The excreta from the cattle housed in stalls are diluted by water used for clearing them. The washed excreta flow into the pit. The average yearly $BOD_5$ concentration of influent is 398.7mg/l. That of the effluent from primary, secondary and tertiary pond of the system is 49.18, 27.9, and 19.8.mg/l respectively. Approximate 88, 93, and 95 % of BOD5 are removed in each pond. The mean yearly SS concentration of influent is 360.5 mg/l That of the effluent from each pond is 53.4, 45.7, and32.7mg/l respectively. Approximate 86, 88, and 91% of SS are removed in each pond. The $BOD_5$ concentration of secondary and tertiary pond can satisfy 30mg/l secondary treatment standard. The SS concentration of effluent from tertiary pond, however, is slightly greater than the standard, which results from activities of carps growing in the pond. The average yearly total nitrogen concentration of influent is 206.8mg/l and that of the effluent from each pond is 48.6, 30.8, and 21.0mg/l respectively. Approximate 74, 88, and 90% of total nitrogen are removed in each pond. The mean yearly total phosphorous concentration of influent is 20.7mg/l and that of the effluent from each pond is 5.3, 3.2, and 2.1mg/l respectively. Approximate 97, 98, and 99% of total phosphorous are removed in each pond. The high removal of nitrogen and phosphorous results from active growth of algae in the upper layer of pond water. Important pond design parameters for southern part of Korea -- areal loading of BOD5, liquid depth, hydraulic detention time, free board, and pond arrangement -- are taken up.

  • PDF

Operation and Perception on Dietary Life Education and Nutrition Counseling of Elementary School in Chungbuk Province (충북지역 초등학교 영양교사의 식생활 교육과 영양상담 운영실태 및 인식)

  • Kim, Myoung-Sil;Kim, Hye Jin;Lee, Young Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.2049-2067
    • /
    • 2013
  • The purpose of this study is to present a more effective nutrition education activation plan. As a result of investigating the dietary education operating situation, 58.9% underwent direct education, and 89.5% underwent food life education through traditional food culture succeeding business operation. The results from investigating the recognition regarding dietary education are as follows. The activation level by education types was as low as 2.24 points, the necessity was as high as 4.54 points, the difficult point in performing food life education was 'overwork' with 4.43 points, and the teaching activity ability level was 'can effectively prepare a teaching guidance plan' at 2.96 points. As a result of investigating the nutrition consultation operating situations, 62.8% underwent it and all of the students as well as some parents and teachers performed it. The consumed time per consultation for effective nutrition consultation was 10~20 minutes, the required education equipment and data were 'consultation program' with 40.3%, and the important content during consultation was 'contents related to eating habits' with 70.5%, which was recognized as the most important.

Nitrogen Removal Rate of A Subsurface Flow Treatment Wetland System Constructed on Floodplain During Its Initial Operating Stage (하천고수부지 수질정화 여과습지의 초기운영단계 질소제거)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.278-283
    • /
    • 2003
  • This study was carried out to examine the nitrogen removal rate of a subsurface-flow treatment wetland system which was constructed on floodplain of the Kwangju River from May to June 2001. Its dimensions were 29m in length, 9m in width and 0.65m in depth. A bottom layer of 45cm in depth was filled with crushed granite with about $15{\sim}30\;mm$ in diameter and a middle layer of 10cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds (Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju River flowed into it via a pipe by gravity flow and its effluent was funneled back into the river. The height of reed stems was 44.2 cm in July 2001 and 75.3cm in September 2001. The number of stems was increased from $80\;stems/m^2$ in July 2001 to $136\;stems/m^2$ in September 2001. Volume and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged 40.0 and $39.2\;m^3/day$, respectively. Hydraulic detention time was about 1.5 days. Average nitrogen uptake by reeds was $69.31\;N\;mg/m^2/day$. Removal rate of $NO_3-N$, $NH_3-N$, T-N averaged 195.58, 53.65, and $628.44\;mg/m^2/day$, respectively. Changes of $NO_3-N$ and $NH_3-N$ abatement rates were closely related to those of wetland temperatures. The lower removal rate of nitrogen species compared with that of subsurface-flow wetlands operating in North America could be attributed to the initial stage of the system and inclusion of two cold months into the six-month monitoring period. Increase of standing density of reeds within a few years will develop both root zones suitable for the nitrification of ammonia and surface layer substrates beneficial to the denitrification of nitrates into nitrogen gases, which may lead to increment in the nitrogen retention rate.