Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units (건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.229-235
    • /
    • 2017
  • In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60~90% of sensitivity and 84~95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

In Situ Monitoring of the MBE Growth of AlSb by Spectroscopic Ellipsometry

  • Kim, Jun-Yeong;Yun, Jae-Jin;Lee, Eun-Hye;Bae, Min-Hwan;Song, Jin-Dong;Kim, Yeong-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.342-343
    • /
    • 2013
  • AlSb is a promising material for optical devices, particularly for high-frequency and nonlinear-optical applications. And AlSb offers significant potential for devices such as quantum-well lasers, laser diodes, and heterojunction bipolar transistors. In this work we study molecular beam epitaxy (MBE) growth of an unstrained AISb film on a GaAs substrate and identify the real-time monitoring capabilities of in situ spectroscopic ellipsometry (SE). The samples were fabricated on semi-insulating (0 0 1) GaAs substrates using MBE system. A rotating sample stage ensured uniform film growth. The substrate was first heated to $620^{\circ}C$ under As2 to remove surface oxides. A GaAs buffer layer approximately 200 nm- thick was then grown at $580^{\circ}C$. During the temperature changing process from $580^{\circ}C$ to $530^{\circ}C$, As2 flux is maintained with the shutter for Ga being closed and the reflection high-energy electron diffraction (RHEED) pattern remaining at ($2{\times}4$). Upon reaching the preset temperature of $530^{\circ}C$, As shutter was promptly closed with Sb shutter open, resulting in the change of RHEED pattern from ($2{\times}4$) to ($1{\times}3$). This was followed by the growth of AlSb while using a rotating-compensator SE with a charge-coupled-device (CCD) detector to obtain real-time SE spectra from 0.74 to 6.48 eV. Fig. 1 shows the real time measured SE spectra of AlSb on GaAs in growth process. In the Fig. 1 (a), a change of ellipsometric parameter ${\Delta}$ is observed. The ${\Delta}$ is the parameter which contains thickness information of the sample, and it changes in a periodic from 0 to 180o with growth. The significant change of ${\Delta}$ at~0.4 min means that the growth of AlSb on GaAs has been started. Fig. 1b shows the changes of dielectric function with time over the range 0.74~6.48 eV. These changes mean phase transition from pseudodielectric function of GaAs to AlSb at~0.44 min. Fig. 2 shows the observed RHEED patterns in the growth process. The observed RHEED pattern of GaAs is ($2{\times}4$), and the pattern changes into ($1{\times}3$) with starting the growth of AlSb. This means that the RHEED pattern is in agreement with the result of SE measurements. These data show the importance and sensitivity of SE for real-time monitoring for materials growth by MBE. We performed the real-time monitoring of AlSb growth by using SE measurements, and it is good agreement with the results of RHEED pattern. This fact proves the importance and the sensitivity of SE technique for the real-time monitoring of film growth by using ellipsometry. We believe that these results will be useful in a number of contexts including more accurate optical properties for high speed device engineering.

  • PDF

Studies on the Residue of Carbofuran (Carbofuran의 잔류(殘溜)에 관(關)한 연구(硏究))

  • Park, Y.D.;Keum, S.S.;Lee, K.S.;Hong, Y.C.
    • Applied Biological Chemistry
    • /
    • v.20 no.2
    • /
    • pp.236-241
    • /
    • 1977
  • Analytical method of carbofuran (2,3-dihydro-2, 2-dimethyl-7-benzofuranyl methyl carbamate) residues and its persistence in rice seeds, rice seedlings, rice plants and soils were studied by gas-liquid chromatographic analysis using electron capture detector. 1. The effective column material for clean-up is Florisil (5% $H_2O$)+Alumina (4% $H_2O$)+absorbent mixture with rinsing the first 300l of eluants to remove impurities in the column materials. 2. The method of applying an gelatin encapsulated carbofuran to the root zone of rice plant is the longest persistence in its residues. 3. By seed treatment, no carbofuran residues were detected in rice seeds and seedlings. 4. The amounts of carbofuran residues in rice seedlings is in proportion to the soaking time of rice seedlings in carbofuran solution rather than the concentration of the chemical. 5. Applying carbofuran by root zone has the higher and the loger residual effect than broadcast. 6. Persistence of carbofuran in the high clay content soil is longer than in the low clay content soil. 7. No carbofuran residue was detected in rough rice at havesting time.

  • PDF

Practicability Assessment of Spherical Type Mechanical Check Device (SMCD) (Mechanical Check용 Spherical Device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Kim, Gun-Oh;Kweon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Purpose: Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and medical treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation therapy area. In order to accommodate the current trend of digital from analog, a spherical type mechanical check device (SMCD) that is form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. Materials and Methods: If the distance maintains constant between source(target) and image detector with constant distance to the center of spherical type mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. Results: It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. Conclusion: It has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Neutron Induced Capture Gamma Spectroscopy Sonde Design and Response Analysis Based on Monte Carlo Simulation (Monte Carlo 시물레이션에 기초한 포획모드 중성자-감마 스펙트럼 존데 설계 및 반응 분석)

  • Won, Byeongho;Hwang, Seho;Shin, Jehyun;Kim, Jongman;Kim, Ki-Seog;Park, Chang Je
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.154-161
    • /
    • 2015
  • For efficiently designing neutron induced gamma spectroscopy sonde, Monte Carlo simulation is employed to understand a dominant location of thermal neutron and classify the formation elements from the energy peak of capture gamma spectrum. A pulsed neutron generator emitting 14 MeV neutron particles was used as a source, and flux of thermal neutron was calculated from the twelve detectors arranged at each 10 cm intervals from the source. Design for reducing borehole effects using shielding materials was also applied to numerical sonde model. Moreover, principal elements and quantities of numerical earth models were verified through the energy spectrum analysis of capture gamma detected from a gamma detector. These results can help to enhance the signal-to-noise ratio, and determine an optimal placement of capture gamma detectors of neutron induced gamma spectroscopy sonde.

Clinical Significance of Measuring Levels of CEA, CA19-9 in Peritoneal Washing Fluid in Patients with Gastric Cancer (위암 환자에서 복강 세척액의 CEA, CA19-9 측정의 임상적 의의)

  • Shim, Gyu-Beom;Park, Ji-Hun;Koo, Tea-Young;Min, Hyun-Sik
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.125-131
    • /
    • 2006
  • Purpose: Free cancer cells exfoliated from cancer-invaded serosa contribute to peritoneal dissemination, the most frequent pattern of recurrence in patients with gastric cancer. To detect free cancer cells, CEA and CA19-9 were introduced as the markers of gastric cancer, and many methods, such as cytology, immunoassay, and reverse transcription polymerase chain reaction (RT-PCR), exist for detecting them. The aim of this study is to define the clinical significance of using immunoassay to measure the levels of CEA and CA19-9 in the peritoneal washings in patients with gastric cancer. Materials and Methods: The peritoneal washing fluids were obtained from 130 patients with gastric cancer who received a curative gastrectomy, palliative gastrectomy or open and closure. The pCEA and pCA19-9 levels were measured by using immunoassay and cytology. The results were compared with the clinicopathological data. Results: The pCEA and pCA19-9 levels were correlated with tumor invasion, lymph-node metastasis, and stage (P<0.05). Conclusion: A correlation was found between elevated pCEA and pCA19-9 levels measured by immunoassay and the TNM stage. Therefore, a combined pCEA and pCA19-9 assay could be a sensitive detector of peritoneal dissemination, as well as a predictor of postoperative prognosis. pCEA and pCA19-9 may also determine the adjuvant management strategy.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

A Study on Unsupervised Learning Method of RAM-based Neural Net (RAM 기반 신경망의 비지도 학습에 관한 연구)

  • Park, Sang-Moo;Kim, Seong-Jin;Lee, Dong-Hyung;Lee, Soo-Dong;Ock, Cheol-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.1
    • /
    • pp.31-38
    • /
    • 2011
  • A RAM-based Neural Net is a weightless neural network based on binary neural network. 3-D neural network using this paper is binary neural network with multiful information bits and store counts of training. Recognition method by MRD technique is based on the supervised learning. Therefore neural network by itself can not distinguish between the categories and well-separated categories of training data can achieve only through the performance. In this paper, unsupervised learning algorithm is proposed which is trained existing 3-D neural network without distinction of data, to distinguish between categories depending on the only input training patterns. The training data for proposed unsupervised learning provided by the NIST handwritten digits of MNIST which is consist of 0 to 9 multi-pattern, a randomly materials are used as training patterns. Through experiments, neural network is to determine the number of discriminator which each have an idea of the handwritten digits that can be interpreted.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

Environmental Geochemistry of Radon at the Taejon City Area in Korea (대전시(大田市) 지역(地域) 라돈 환경(環境) 지화학(地化學) 연구(硏究))

  • Hong, Young-Kook
    • Economic and Environmental Geology
    • /
    • v.30 no.1
    • /
    • pp.51-60
    • /
    • 1997
  • The high radon (Rn222) potentials of soil, groundwater, hotspring and indoor environments in the Taejon city area were delineated by use of an EDA RDA-200 radon detector. The U and Th contents were also analysed using a Multi Channel Analyzer to illustrate the sources of the radon potentials. The average U concentrations in Taejon vary according to the type of granites such as $4.14{\pm}2.36ppm$ in schistose granite (SG), $3.13{\pm}1.70ppm$ in biotite granite (BG) and $3.01{\pm}1.95ppm$ in two mica granite (TG). The U contents in the granites are closely related with the amounts of uraniferous minerals. However, the U contents in the soil are found to be $5.05{\pm}4.75ppm$ in TG, $4.07{\pm}1.69ppm$ in BG and $3.87{\pm}1.91ppm$ in SG which are mainly explained by the different cation exchange capacities (CEC) of the soils from various granites. The levels of soil radon are $552{\pm}656pCi/l$ in SG, in which levels at two locations exceed the level of 1,350 pCi/l established as guideline for follow-up action by the U.S. Environmental Protection Agency (EPA), $443{\pm}284pCi/l$ in TG and $224{\pm}115pCi/l$ in the BG. The soil radon concentrations are found to be proportional to the U content and hardness of the soils. The groundwater radon concentrations in the domestic wells of - 30~-100 m depth show that $6,907{\pm}4,665pCi/l$ in TG, $5,503{\pm}6,551pCi/l$ in SG and $2,104{\pm}1,157pCi/l$ in BG which are positively related with U contents in soils. The radon levels of six groundwater wells in TG and two in SG are greater than guideline for drinking water level, 10,000 pCi/l by EPA (1986). Average radon contents of hotsprings and public bathes in the TG area are $7,071{\pm}1,942pCi/l$ and $1,638{\pm}709pCi/l$, respectively, which are below the EPA standard for remedial action value of the 10,000 pCi/l. The mean indoor radon concentrations of the TG and SG areas are $1.60{\pm}1.20pCi/l$ and $1.60{\pm}0.70pCi/l$, respectively. The elevated indoor radon levels of 5.6 pCi/l and 6.7 pCi/l are found to be particularly in TG area, which exceeds 4 pCi/i guideline, correlating positively with the U contents in the soil and radon concentration in the groundwater.

  • PDF