• Title/Summary/Keyword: Detector materials

Search Result 503, Processing Time 0.035 seconds

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

Radiation-induced transformation of Hafnium composition

  • Ulybkin, Alexander;Rybka, Alexander;Kovtun, Konstantin;Kutny, Vladimir;Voyevodin, Victor;Pudov, Alexey;Azhazha, Roman
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1964-1969
    • /
    • 2019
  • The safety and efficiency of nuclear reactors largely depend on the monitoring and control of nuclear radiation. Due to the unique nuclear-physical characteristics, Hf is one of the most promising materials for the manufacturing of the control rods and the emitters of neutron detectors. It is proposed to use the Compton neutron detector with the emitter made of Hf in the In-core Instrumentation System (ICIS) for monitoring the neutron field. The main advantages of such a detector in comparison the conventional β-emission sensors are the possibility of reaching of a higher cumulative radiation dose and the absence of signal delays. The response time of the detection is extremely important when a nuclear reactor is operating near its critical operational parameters. Taking Hf as an example, the general principles for calculating the chains of materials transformation under neutron irradiation are reported. The influence of 179m1Hf on the Hf composition changing dynamics and the process of transmutants' (Ta, W) generation were determined. The effect of these processes on the absorbing properties of Hf, which inevitably predetermine the lifetime of the detector and its ability to generate a signal, is estimated.

Analytical-numerical formula for estimating the characteristics of a cylindrical NaI(Tl) gamma-ray detector with a side-through hole

  • Thabet, Abouzeid A.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3795-3802
    • /
    • 2022
  • NaI(Tl) scintillation materials are considered to be one of many materials that are used exclusively for γ-ray detection and spectroscopy. The gamma-ray spectrometer is not an easy-to-use device, and the accuracy of the numerical values must be carefully checked based on the rules of the calibration technique. Therefore, accurate information about the detection system and its effectiveness is of greater importance. The purpose of this study is to estimate, using an analytical-numerical formula (ANF), the purely geometric solid angle, geometric efficiency, and total efficiency of a cylindrical NaI(Tl) γ-ray detector with a side-through hole. This type of detector is ideal for scanning fuel rods and pipelines, as well as for performing radio-immunoassays. The study included the calculation of the complex solid angle, in combination with the use of various points like gamma sources, located axially and non-axially inside the through detector side hole, which can be applied in a hypothetical method for calibrating the facility. An extended γ-ray energy range, the detector, source dimensions, "source-to-detector" geometry inside the side-through hole, path lengths of γ-quanta photons crossing the facility, besides the photon average path length inside the detector medium itself, were studied and considered. This study is very important for an expanded future article where the radioactive point source can be replaced by a volume source located inside the side-trough hole of the detector, or by a radioactive pipeline passing through the well. The results provide a good and useful approach to a new generation of detectors that can be used for low-level radiation that needs to be measured efficiently.

Study on Applicability of the Vehicle Detection Using a Coil Sensor (코일센서를 이용한 차량검지기 적용성에 대한 연구)

  • Lee, Sang-O;Lee, Choul-Ki;Yun, Ilsoo;Kim, Nam-Sun;Lee, Yong-Ju
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.2
    • /
    • pp.14-23
    • /
    • 2015
  • This study was intended to evaluate the feasibility of the vehicle detector using a coil sensor. For the evaluation, the research team built a test environment for the detector consisting of a oscillation circuit, data collecting circuit, data monitoring and saving circuit, etc. As the result of the frequency analysis of the detector from the test environment, it was verified for the detector using a coil sensor to generate stable frequencies. In addition, the ease of construction and management was tested by comparing the size of cutting areas, consumption of installation materials, and installation time for a traditional loop detector and the detector using a coil sensor. As a result, the installation of the detector using a coil sensor requires less size of cutting areas, consumption of installation materials, and installation time.

Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector (Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가)

  • Seo, Jung-Ho;Lim, Hyun-Woo;Park, Jin-Goo;Huh, Young;Jeon, Sung-Chea;Kim, Bong-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

The Development of UV-IR Combination Flame Detector (UV-IR 복합형 화재감지장치 개발)

  • 이복영;권오승;정창기;박상태
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

Quantification of Inulo-oligosaccharides Using High pH Anion Exchange Chromatography with Pulsed Amperometric Detector (HPAEC-PAD)

  • Kang, Su-Il;Chang, Yung-Jin;Kim, Kyoung-Yun;Kim, Su-Il
    • Journal of Applied Biological Chemistry
    • /
    • v.42 no.4
    • /
    • pp.166-168
    • /
    • 1999
  • Inulo-oligosaccharides (IOS, $F_n$, n=2-6) were purified from enzymatic hydrolysates of water-soluble extract of Jerusalem artichoke tubers. Quantification of inulo-oligosaccharides was done using high pH anion exchange chromatography with pulsed amperometric detector (HPAEC-PAD) at the concentration range of 10-100 mg/L, which was compared with that of fructo-oligosaccharides (FOS, $GF_n$, n=1-7). Peak areas per mg IOS were higher than FOS at the same degree of polymerization (DP). Specific peak areas of IOS increased proportionally as DP increased up to six, in contrast to FOS showing no linearity.

  • PDF