• 제목/요약/키워드: Detection of partial discharge signal

검색결과 79건 처리시간 0.027초

장시간 절연체 열화실험을 위한 부분방전측정기술 연구 (A Study on the Technology Measuring Partial Discharge for Long Term Aging Experiments of Insulation Materials)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.665-672
    • /
    • 2000
  • This paper described the measurement technology to analyze the partial discharge characteristics for long term aging of insulations. This system was consisted of high voltage generation and measurement part, PD detection part, digital conversion and signal processing part. We used the VXI system for digital conversion and signal processing part. In the digital conversion part, we studied the error of partial discharge magnitude and memory capacity for reading digital signal with the sampling rate. In the signal processing part, we showed the program algorithm to count pulses and read peak values of partial discharge. The allowable minimum sampling rate of digizer was decided to 250kS/s through analyzing test. We confirmed that this system was very useful in the study of $\phi-q-n$ characteristics of long term PD experiments with specimens being consisted of internal void defects and CIGRE II electrodes.

  • PDF

광섬유 간섭계 센서를 이용한 부분방전 음압 측정 (Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor)

  • 이종길;박윤석;이준호
    • 한국음향학회지
    • /
    • 제21권7호
    • /
    • pp.614-623
    • /
    • 2002
  • 본 논문에서는 전력설비의 열화로 발생되는 부분방전 음압 검출을 위해 간섭계형 광섬유 센서를 제작하고 방전 음압을 측정하였다. 광섬유 센서는 아크릴과 알루미늄에 광섬유를 수회 감은 맨드릴형으로 선택하였으며, 간섭계는 Sagnac간섭계 및 Mach-Zehnder 간섭계를 선택하여 실험하였다. 피에조 (PZT)를 이용하여 구성된 광섬유 간섭계의 적합성을 확인하였다. 방전 음압 발생장치는 절연유 내에 방전 모의셀을 설치하여 방전 음압을 발생시키고, 광섬유 센서로 방전신호를 검출하였다. 실험결과 Sagnac 간섭계가 Mach-Zehnder간섭계보다 방전 음압을 보다 안정적으로 검출함을 확인하였으며, Sagnac 간섭계 센서가 방전 음압 검출에 적합함을 확인하였다.

웨이블렛 변환을 이용한 부분 방전 신호 분석 (An Analysis of Partial Discharge signal Using Wavelet Transforms)

  • 박재준;장진강;임윤석;심종탁;김재환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1999
  • Recently, the wavelet transform has been a new and powerful tool for signal processing. It is more suitable specially for the feature extraction and detection of non-stationary signals than traditional methods such as, the Fourier Transform(FT), the Fast Fourier Transform(FFT) and the Least Square Method etc. because of the characteristic of the multi-scale analysis and time-frequency domain localization. The wavelet transform has been developed for the analysis of PD pulse signal to raise in the progress of insulation degradation. In this paper, the wavelet transform was applied to one foundational method for feature extraction. For the obtain experimental data, a computer-aided partial discharge measurement system with a single acoustic sensor was used. If we are applying to the neural network method the accumulated data through the extracted feature, it is expected that we can detect the PD pulse signal in the insulation materials on the on-line.

  • PDF

발전기 권선에서의 신호전송 특성에 관한 연구 (A Study on the Signal Propagation Characteristics of Generator Windings)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1299-1303
    • /
    • 1995
  • The detection and measurement of partial discharge activity prevalent in the solid insulating systems of high-voltage generator stator windings has, for many years, been a recognized method of assessing the insulation condition of such systems. Partial discharge activity occurs at sites of degradation within, or at the surface of, stator's insulation systems under high voltage stressing. However, partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. The mode of transmission varies with the signal frequency and is dependant on the geometrical configurations of windings. This paper reports the investigated results of the signal propagation characteristics along the windings when both sinusoidal signals and simulated partial discharge pulses are injected at the various positions of stator windings within the 25 MVA, 11 kV hydro generator. The on-line identification technique of partial discharge location in generator windings is also proposed in this study.

  • PDF

154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 (HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 이정수;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.214-217
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding Power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

원격감시 기능을 갖는 고감도 부분방전센서 (Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities)

  • 최규남
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.349-356
    • /
    • 2015
  • 광학적 잡음과 전기적 잡음을 복합적으로 제거할 수 있는 하이브리드 필터를 채용하고 펄스형태의 아크 광 신호를 적분하여 수신되는 아크에너지의 크기로 감지할 수 있는 원격감시 기능을 갖는 고감도 부분방전 센서를 구현하였다. 하이브리드 필터는 부분방전 센서가 설치되는 배전반 내 환경에서 내부 형광등과 백열등 조명에 대하여 영향을 받지 않음을 보여주었다. 종래에는 아크광의 불규칙한 파형특성으로 인하여 첨두치가 감지되어 아크광의 크기에 비례한 선택적 감지가 어려웠으나, 센서에 적용된 적분연산 기능은 각기 다른 아크광의 에너지 레벨에 대하여도 선택적으로 감지가 가능함을 실험적으로 보여주었다. 센서는 2m 이격된 원격지에서 100A 저압 MCCB의 정상 개폐 시 발생하는 섬광에 해당하는 광 에너지에 대해서도 감지가 가능함을 보여주어 원격감시 기능을 갖는 고감도 부분방전센서에 적용 가능함을 보여주었다.

유중 부분방전의 음향검출에 관한 연구 (A Study on the Acoustic Detection of Partial Discharges in Insulation Oil)

  • 길경석;김성욱;박대원;김선재;송재만
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

배전용 전력 케이블 접속재의 내부고장 검출에 관한 기초연구 (A Basic Study on Detection of Internal Defects in Distribution Cable Splices)

  • 박치영;진상범;곽희로;김상준;송일근;권동진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.122-124
    • /
    • 1996
  • This paper describes a diagnosis of distribution cable splices by analysis of ultrasonic signals which are generated by partial discharge. A method of ultrasonic signal was used to detect internal defects in distribution cable splices. It is possible that analysis of ultrasonic signal predicts failure by partial discharge generated in distribution cable splices.

  • PDF

상호상관법을 이용한 변압기내의 부분방전 위치측정 (Position prediction method of Partial discharge in power transformer using Cross-correlation)

  • 문영재;구춘근;이상철;정찬수;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.934-937
    • /
    • 1992
  • The partial discharge signal can be used as the detection signal of the deterioration of the power transformer insulation. Detecting this signal, the insulation failure and the point, in which the partial discharge is generated, could be predicted. In this paper, we study to predict the point, and find that the cross correlation method could predict the point accurately. Also, experimental system and the results are presented here.

  • PDF

변압기내 노이즈제거를 통한 초음파 신호 검출 (Ultrasonic Signal Detection in a Transformer Through Noise Elimination)

  • 박현수;곽희로;박중신
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.231-234
    • /
    • 2000
  • The corona in oil, the surface discharge in oil, the void discharge which could be in a transformer were imitated by using three electrodes with different shapes and the frequency bands of each ultrasonic signal were measured. After emitting artificial noises toward the transformer, only ultrasonic signals were extracted by frequency filtering, from the ultrasonic signals with noises at partial discharge. As a result, it was confirmed that the ultrasonic signals due to the corona in oil, the surface discharge in oil, the void discharge could be distinguished from the noises.

  • PDF