• Title/Summary/Keyword: Detection concentration

Search Result 1,839, Processing Time 0.039 seconds

An Intrusion Detection Method Based on Changes of Antibody Concentration in Immune Response

  • Zhang, Ruirui;Xiao, Xin
    • Journal of Information Processing Systems
    • /
    • v.15 no.1
    • /
    • pp.137-150
    • /
    • 2019
  • Although the research of immune-based anomaly detection technology has made some progress, there are still some defects which have not been solved, such as the loophole problem which leads to low detection rate and high false alarm rate, the exponential relationship between training cost of mature detectors and size of self-antigens. This paper proposed an intrusion detection method based on changes of antibody concentration in immune response to improve and solve existing problems of immune based anomaly detection technology. The method introduces blood relative and blood family to classify antibodies and antigens and simulate correlations between antibodies and antigens. Then, the method establishes dynamic evolution models of antigens and antibodies in intrusion detection. In addition, the method determines concentration changes of antibodies in the immune system drawing the experience of cloud model, and divides the risk levels to guide immune responses. Experimental results show that the method has better detection performance and adaptability than traditional methods.

Gold Nanoparticle-Based Detection of Hg(II) in an Aqueous Solution: Fluorescence Quenching and Surface-Enhanced Raman Scattering Study

  • Ganbold, Erdene-Ochir;Park, Jin-Ho;Ock, Kwang-Su;Joo, Sang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.519-523
    • /
    • 2011
  • We studied the detection of the Hg(II) concentration in an aqueous solution using rhodamine dyes on citrate-reduced Au nanoparticles (NPs). The quenching effect from Au NPs was found to decrease as the Hg(II) concentration increased under our experimental conditions. As the fluorescence signals intensified, the surface-enhanced Raman scattering (SERS) intensities reduced on the contrary due to less rhodamine dyes on Au NPs as the Hg(II) concentration increased. The rhodamine 6G (Rh6G) and rhodamine 123 (Rh123) dyes were examined via fluorescence and SERS measurements depending on Hg(II) concentrations. Fast and easy fluorescence detection of an Hg (II) concentration as low as a few ppm could be achieved by naked eye using citrate-reduced Au NPs.

Detection of Face Direction by Using Inter-Frame Difference

  • Jang, Bongseog;Bae, Sang-Hyun
    • Journal of Integrative Natural Science
    • /
    • v.9 no.2
    • /
    • pp.155-160
    • /
    • 2016
  • Applying image processing techniques to education, the face of the learner is photographed, and expression and movement are detected from video, and the system which estimates degree of concentration of the learner is developed. For one learner, the measuring system is designed in terms of estimating a degree of concentration from direction of line of learner's sight and condition of the eye. In case of multiple learners, it must need to measure each concentration level of all learners in the classroom. But it is inefficient because one camera per each learner is required. In this paper, position in the face region is estimated from video which photographs the learner in the class by the difference between frames within the motion direction. And the system which detects the face direction by the face part detection by template matching is proposed. From the result of the difference between frames in the first image of the video, frontal face detection by Viola-Jones method is performed. Also the direction of the motion which arose in the face region is estimated with the migration length and the face region is tracked. Then the face parts are detected to tracking. Finally, the direction of the face is estimated from the result of face tracking and face parts detection.

Performance Characteristics of In-Situ Particle Monitors at Sub-Atmospheric Pressure (감압상태에서의 In-Situ Particle Monitor의 성능특성)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1564-1570
    • /
    • 1998
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at subatmospheric pressures has been studied. We created uniform upstream conditions of particle concentration and measured the detection efficiency, the lower detection limit, and the size response of the ISPM using uniform sized methylene blue aerosol particles. The effect of particle size, particle velocity, particle concentration, and system pressure on the detection efficiency was examined. Results show that the detection efficiency of the ISPM decreases with decreasing chamber pressure, and with increasing mass flow rate. The lower detection limit of the ISPM, determined at 50 % of the measured maximum detection efficiency, was found to be about $0.15{\sim}0.2{\mu}m$, which is similar to the minimum detectable size of $0.17{\mu}$ given by the manufacturer.

Knock Detection Using an Ionization Probe Installed Spark Plug (이온프로브 장착 점화플러그를 이용한 노크발생 판정)

  • 한성주;이용규;민경덕;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.1-8
    • /
    • 2000
  • A new method of knock detection in SI engines, using a change of ion concentration in the combustion chamber, was developed. In order to measure in-cylinder ionization current, ionization probes were installed at spark plug and cylinder head of production engine. It was found that the electric current generated by ionized gas in core burned gas region of knocking cycle is between 2 and 10 times larger than that of normal cycle, because the burned gas temperature which is the dominant parameter of a change of ion concentration increases. However, a change of ionization current in boundary region of burned gas is relatively weak. Hence a change of ion concentration in core burned gas region can be used for knock detection.

  • PDF

Studies on Enzyme-linked Immunosorbent Assay(ELISA) for Detection of Antibody to Mycobacterium bovis in Serum and Milk (Enzyme-linked Immunosorbent Assay(ELISA)를 이용한 혈청 및 원유 중의 Mycobacterium bovis 항체 검출에 관한 연구)

  • 심항섭;국정희;박병옥;김성열;박유순
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.2
    • /
    • pp.133-142
    • /
    • 1997
  • In order to supplement a diagnostic method for detection of infectious cattle to bovine tuberculosis, performed ELISA for detection of antibody to if bovis in serum and milk. The diagnostic efficacy of the established ELISA was compared with test of the tuberculin skin test for bovine tuberculosis. The positive corresponding rate of serum ELISA and tuberculin skin test showed 84.3%, milk ELISA and tuberculin skin test showed 75.0%, milk ELISA and serum ELISA showed 75.0% respectively. Comparison of the serum and milk to tuberculin antibody concentration in tuberculin positive cattle, the milk contained 1/100-1/150 concentration compared serum tuberculin concentration. The established ELISA was considered efficient for detection of antibodies to M bovis in serum and milk.

  • PDF

Study on The Measurement of Corrosion Product Concentration in The Feed Water System of A Power Plant (발전소 급수계통 부식생성물 농도 측정에 관한 연구)

  • Moon, Jeon Soo;Lee, Jae Kun
    • Corrosion Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.151-155
    • /
    • 2011
  • The iron oxide particles could be resulted from the corrosion of the circulating water system of a power plant. Because it may be one of the trouble materials which affect the power generation efficiency due to the deposition on steam generator tube and turbine blade, the continuous observation of its concentration is very important. The laser induced break-down detection (LIBD) technology was applied to monitor continuously the concentration of corrosion products with the detection limit of ppb level. The measurement system consists of a Nd:YAG pulsed laser, a polarizing beam splitter, a flow-type sample cell, an acoustic emission sensor, a high speed data acquisition board, a personal computer, etc.. The performance test results confirmed that this technology can be effective to monitor the corrosion product concentration of the circulating water system of a power plant.

Chromatic Detection of Cholesterol Using Polydiacetylene Vesicles

  • Min Jae Shin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.660-664
    • /
    • 2023
  • In this study, a new system to determine the concentration of cholesterol using a color change was developed. The system comprised diacetylene vesicles and cholesterol oxidase (ChOx). 10,12-Pentacosadiynoic acid (PCDA) was used as the diacetylene compound, and PCDA vesicles were formed using sonication. The H2O2 produced during the reaction between cholesterol and ChOx was used to initiate the polymerization of the PCDA in the vesicles. During polymerization, the vesicles changed from colorless to blue. Therefore, the cholesterol concentration was proportional to the intensity of the blue color. The absorption at 665 nm indicated that the blue color was directly proportional to the cholesterol concentration. This indicates that the system can be used for cholesterol detection. The minimum cholesterol concentration detected using this system was 1.0 mM.

Concentration Distribution of Polychlorinated Biphenyls(PCBs) in Urban Watershed (도심하천유역의 PCBs 농도 분포)

  • Kim, Hyun-Seung;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.757-766
    • /
    • 2012
  • In this study, we have examined concentration distribution and patterns of PCBs in waters, sediments and soils in an agricultural area of South Korea to investigate the relationship between PCBs sources and concentration levels. The concentration of PCBs in water samples were ranged from lower values below detection limit to 8.25 ug/L and the concentration of PCBs in sediment samples were ranged from lower values below detection limit to 76.67 ug/Kg. The concentration of PCBs in soil samples were ranged from lower values below detection limit to 23.51 ug/Kg. These contamination levels were far below the guideline values suggested for environmental quality assessment. The homologue patterns in samples varied from sample to sample, but isomer patterns were very similar with each other. PCB-138 and PCB-153 were predominant congeners in the soil and sediment, which were similar to the results obtained from previous studies. With these results, the assessment of potential sources of PCBs contamination in the sediments of the Nakdong river basin was performed. The principal components were extracted by Principal Component Analysis(PCA). As the result of PCA, it could be expected that PCBs in samples of this study were more affected by PCB products than combustion processes and mostly affected by already-known sources. The PCBs in the soil and sediment samples were related with commercial PCB products.

Detection of Norovirus in Contaminated Ham by Reverse Transcriptase-PCR and Nested PCR

  • Kim, Seok-Ryel;Kim, Du-Woon;Kwon, Ki-Sung;Hwang, In-Gyun;Oh, Myung-Joo
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.651-654
    • /
    • 2008
  • In order to enhance the efficacy of norovirus detection by reverse transcriptase-polymerase chain reaction (RT-PCR) and nested PCR, this study developed a norovirus mRNA concentration method using poly oligo dT-conjugated magnetic beads. An efficient norovirus detection protocol was performed on commercial ham using 2 viral elution buffers (glycine buffer and Tris beef extract buffer) and 2 concentration solutions [polyethylene glycol (PEG) and zirconium hydroxide]. The different approaches were verified by RT-PCR and nested PCR. This method was performed on ham in less than 8 hr by artificial inoculation of serial dilutions of the virus ranging from 1,000 to 1 RT-PCR unit/mL. The viral extraction and concentration method had 10-fold higher sensitivity using the combination of Tris beef extract buffer and PEG as compared to glycine buffer and zirconium hydroxide. This method proved that RT-PCR and nested PCR have the sensitive ability to detect norovirus in commercial ham, in that norovirus was successfully detected in artificially contaminated samples at a detection level as low as 1-10 RT-PCR unit/mL. Overall, such a detection limit suggests this protocol is both quick and efficient in terms of its potential use for detecting norovirus in meat products.