• Title/Summary/Keyword: Detection Index

Search Result 862, Processing Time 0.026 seconds

Dynamic Hepatic Blood Flow Scan of Liver Cirrhosis by Arterialization Index (동맥혈화지표 (Arterialization Index)를 이용한 간경화증의 혈류측정)

  • Kim, I.Y.;Yoo, H.S.;Lee, J.T.;Park, C.Y.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.2
    • /
    • pp.19-24
    • /
    • 1983
  • The purpose of this study was to develop a method by which the sensitivity of radionuclide liver imaging for detection of liver cirrhosis could be enhanced. Dynamic blood flow scan were performed 21 cases of liver cirrhosis patients by using computerized gamma camera named arterialization index. The results were as follows: 1) Arterialization index were higher in liver cirrhosis comparing to normal value 0.33 and its mean is 2. 02. 2) Comparing to static liver scan, higher sensitivity in dynamic hepatic blood flow scan for detection of liver cirrhosis. Sensitivity for detection of liver cirrhosis is over 90%. 3) There are no correlation between arterialization index and serum albumin level. The use of hepatic dynamic blood flow scan proved effective in detection of liver cirrhosis. However, the test may be used as an aid in distinguishing between normal and pathologic livers.

  • PDF

Structural damage detection using a damage probability index based on frequency response function and strain energy concept

  • Bagherahmadi, Seyed Ahdiye;Seyedpoor, Seyed Mohammad
    • Structural Engineering and Mechanics
    • /
    • v.67 no.4
    • /
    • pp.327-336
    • /
    • 2018
  • In this study, an efficient damage index is proposed to identify multiple damage cases in structural systems using the concepts of frequency response function (FRF) matrix and strain energy of a structure. The index is defined based on the change of strain energy of an element due to damage. For obtaining the strain energy stored in elements, the columnar coefficients of the FRF matrix is used. The new indicator is named here as frequency response function strain energy based index (FRFSEBI). In order to assess the performance of the proposed index for structural damage detection, some benchmark structures having a number of damage scenarios are considered. Numerical results demonstrate that the proposed index even with considering noise can accurately identify the actual location and approximate severity of the damage. In order to demonstrate the high efficiency of the proposed damage index, its performance is also compared with that of the flexibility strain energy based index (FSEBI) provided in the literature.

A direct damage detection method using Multiple Damage Localization Index Based on Mode Shapes criterion

  • Homaei, F.;Shojaee, S.;Amiri, G. Ghodrati
    • Structural Engineering and Mechanics
    • /
    • v.49 no.2
    • /
    • pp.183-202
    • /
    • 2014
  • A new method of multiple damage detection in beam like structures is introduced. The mode shapes of both healthy and damaged structures are used in damage detection process (DDP). Multiple Damage Localization Index Based on Mode Shapes (MDLIBMS) is presented as a criterion in detecting damaged elements. A finite element modeling of structures is used to calculate the mode shapes parameters. The main advantages of the proposed method are its simplicity, flexibility on the number of elements and so the accuracy of the damage(s) position(s), sensitivity to small damage extend, capability in prediction of required number of mode shapes and low sensitivity to noisy data. In fact, because of differential and comparative form of MDLIBMS, using noise polluted data doesn't have major effect on the results. This makes the proposed method a powerful one in damage detection according to measured mode shape data. Because of its flexibility, damage detection process in multi span bridge girders with non-prismatic sections can be done by this method. Numerical simulations used to demonstrate these advantages.

Small Target Detection Method under Complex FLIR Imagery (복잡한 FLIR 영상에서의 소형 표적 탐지 기법)

  • Lee, Seung-Ik;Kim, Ju-Young;Kim, Ki-Hong;Koo, Bon-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.4
    • /
    • pp.432-440
    • /
    • 2007
  • In this paper, we propose a small target detection algorithm for FLIR image with complex background. First, we compute the motion information of target from the difference between the current frame and the created background image. However, the slow speed of target cause that it has the very low gray level value in the difference image. To improve the gray level value, we perform the local gamma correction for difference image. So, the detection index is computed by using statistical characteristics in the improved image and then we chose the lowest detection index a true target. Experimental results show that the proposed method has significantly the good detection performance.

  • PDF

Damage Detection of Shear Building Structures Using Dynamic Response (동적응답신호를 이용한 전단형 건물의 손상추정)

  • Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.101-107
    • /
    • 2014
  • Damage location and extent of structure could be detected by the inverse analysis on dynamic response properties such as frequencies and mode shapes. The dynamic response of building structures has many noise and affected by nonstructural members and, above all, the behavior of building structure is more complex than civil structure and this makes the damage detection difficult. In recent researches the damage is detected by the indirect index such as sensitivity or assumed values. However, for the more reasonable damage detection, it needs to use the damage index directly induced from dynamic equation. The purpose of this study is to provide the damage detection method on shear building structures by the damage index directly induced from dynamic equation. The provided damage index could be estimated from measured mode shape of undamaged structure and frequency difference between undamaged and damaged structure. The damage detection method is applied to numerical analysis model such as MATLAB and MIDAS GENw for the verification. The damage index at damaged story represents (-) sign and 15 times than other undamaged sories.

Economic Evaluation of Early Detection System for Warranty Issues (품질보증 이슈 조기감지 시스템의 경제성 평가)

  • Jung, Sung-Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.1
    • /
    • pp.39-48
    • /
    • 2012
  • An early detection system for warranty issues periodically collects customers' claim data and automatically reports alarms about emerging issues based on statistical algorithms. It helps companies to reduce an issue definition time and save the handling cost of warranty claims. This paper provides an evaluation framework to validate the economic effect of an early detection system project. For this purpose, we present economical index of a project with explicit formulas such as ROI(return on investment), PP(payback period), NPV(net present value), PI(profitability index) and IRR(internal rate of return) and analyze the sensitivities of the index according to the variation of project input parameters. The proposed analysis framework is expected to be used for evaluating economic values of various system integration projects.

Output Voltage Control of Z-Source Inverter by the Detection of the Input DC Voltage and Z-Network Capacitor Voltage (입력 직류 전압과 Z-네트워크 커패시터 전압 검출에 의한 Z-소스 인버터의 출력 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposes the algorithm for the output AC voltage control of Z-source inverter by the detection of the input DC voltage and Z-network capacitor voltage. The actual modulation index of the proposed method is detected by the capacitor voltage in Z-network and input DC voltage of three-phase Z-source inverter. Control modulation index for the output voltage control is calculated by the detected actual modulation index and reference modulation index. And, calculated control modulation index is applied to the modified space vector modulation (SVM) for control the output voltage of Z-source inverter. To verify the validity of the proposed method, PSIM simulation was achieved and a DSP controlled 1[kW] three-phase Z-source inverter was producted. The simulation and experiment were performed under the condition that the load was changed in case of the constant input DC voltage and the input DC voltage was changed in case of the load was constant. As a result, we could know that the output phase voltage of Z-source inverter followed to the reference voltage 70[VRMS] despite the load or the input DC voltage were suddenly changed.

On the Improvement of Error Performance in the Differential Detector for 3-h CPM (3-h CPM 차동 검파기의 오율 성능 개선)

  • 홍의식;한영열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.3
    • /
    • pp.240-246
    • /
    • 1992
  • In the paper, the differential detection techniques of 3-h CPM signals whose modulation index is varied periodically are proposed and their error performances are analyzed. We select the modulation index sets which are proper to the differential detection and propose the differential detectors which detect symbol with 3 bits per smapling period of 3T and detect a bit per sampling period of T. Applying the nonredundant error correction circuit and viterbi algorithm to differential detection of 3-h CPM. We ascertain the error performances are improved.

  • PDF

A Study on the Differential Detection of Multi-h Continuous Phase Modulation (Multi-h CPM의 차동 검파에 관한 연구)

  • 홍희식;한영열
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.3
    • /
    • pp.8-14
    • /
    • 1992
  • In this paper, the differential detection technique of multi-h CPM is introduced and described. We derived the sets of modulation index of multi-h phase codes adequate to the differential detection. The power spectra of multi-h signals with various sets of modulation index are presented and compared to those of MSK and QPSK. Error rate performances of the conventional detector and Viterbi algorithm detector of 2-h and 3-h CPM are evaluated and compared.

  • PDF

The misfire detection using the mean exhaust pressure gradient index (평균 배기 압력 구배 지수를 이용한 실화 검출)

  • Chung, Sung-Won;Sim, Kook-Sang;Kim, Se-Woong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.4
    • /
    • pp.371-378
    • /
    • 2001
  • This paper proposes a method to detect the misfired cylinder using a new misfire detection index. The new method of misfired cylinder is a comparison of pressure gradient during the blowdown period of exhaust stroke. If a misfire occurs, the engine will he lost some power and consumes the more fuel and the torque will be unsteady. Most of all, the misfire affects a bad influence of the 3-way catalyst and emits unburned hydrocarbon in the air. To prevent these unusual phenomena and eliminate the factor of the environmental pollution, it is important to detect the misfired cylinder. To do the experiment, set up the assist device on the manifold. This assist device is not deformed for conventional exhaust manifold and installed in the end of the exhaust manifold. Experimental results showed that the method using the mean gradient pressure index is proven to be effective in the detection of misfired cylinder on gasoline engine regardless loads and revolutions of the engine.

  • PDF