• 제목/요약/키워드: Design wastewater flow rate

검색결과 38건 처리시간 0.026초

Direct Horizontal-Flow Roughing Filtration의 조립 여상에서의 입자 제거 모델링 (Modeling of Particle Removal in the Coarse Media of Direct Horizontal-Flow Roughing Filtration)

  • 안효원;박노석;이선주;이경혁;왕창근
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.338-347
    • /
    • 2005
  • Horizontal-Flow Roughing Filtration (HRF) is one of altemative pretreatment methods e.g. prior to Slow Sand Filtration (SSF). However, some of its limitations are that the effluent quality drops drastically at higher turbidity (>200 NTU) and at higher filtration rate (>1 m/h). To overcome these drawbacks, we suggested Direct Horizontal-Flow Roughing Filtration (DHRF), which is a modified system of Horizontal-Flow Roughing (HRF) by addition of low dose of coagulant prior to filtration. In this study to optimize the DHRF configuration, a conceptual and mathematical model for the coarse compartment has been developed in analogy with multi-plate settlers. Data from simple column settling test can be used in the model to predict the filter performance. Furthermore, the model developed herein has been validated by successive experiments carried out. The conventional column settling test has been found to be an handy and useful to predict the performance of DHRF for different raw water characteristics (e.g. coagulated or uncoagulated water, different presence of organic matter, etc.) and different inital process conditions (e.g. coagulant dose, mixing time and intensity, etc.). An optimum filter design for the coarse compartment (grain size 20mm) has been found to be of 3 m/h filtration rate with filter length of 4-4.5 m.

수치모의를 통한 침사지에서의 흐름 및 침사효율 해석 (Numerical analysis of flow and settling efficiency in a sedimentation basin)

  • 김대근;김성만;박원철
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.713-722
    • /
    • 2010
  • This paper has assessed the flow patterns and settling efficiency in the sedimentation basin using the particle tracking method of the CFD code and has reached the following conclusions: In the original design where no baffle is installed in the sedimentation basin, a large recirculating area where the flow stagnates is created in the right side of the sedimentation basin, with most of the particles moving to the left side of the sedimentation basin following the flow. This biased flow structure in the sedimentation basin reduces the residence time of particles and thereby undermines settling efficiency. The biased flow toward the left side of the sedimentation basin is alleviated by installing a baffle in the sedimentation basin, promptly reducing the fast flow of over 0.7 m/s in the inlet of the sedimentation basin to the rate below 0.2 m/s. In this paper's simulation conditions, if a one-sided baffle is to be installed in the sedimentation basin, placing it 15 meters away from the basin's inlet leads to the best settling efficiency; it has also been analyzed that installing a two-sided baffle-rather than a one-sided one-is a better option in terms of settling efficiency. The highest settling efficiency of 96.2% is achieved when the underwater length of the two-sided baffle is set at 8 meters.

청천시 오수량을 고려한 합류식 하수도 소류력 설계법과 이를 활용한 하수관거 개보수방안 (A combined sewer design method using tractive force considering wastewater flow on non-rainy days and its application for improvement methods of sewer)

  • 지현욱;유성수;송호면;강정희
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.211-220
    • /
    • 2020
  • When domestic sewage and rainwater runoff are discharged into a single sewer pipe, it is called a "combined sewer system." The sewage design standards in Korea specify the flow velocity based only on the volume of rainfall; therefore, sedimentation occurs on non-rainy days owing to the reduced flow rate and velocity. This sedimentation reduces the discharge capacity, causes unpleasant odors, and exacerbates the problem of combined sewer overflow concentration. To address this problem, the amount of sewage on non-rainy days, not just the volume of rainfall, should also be considered. There are various theories on sedimentation in sewer movement. This study introduces a self-cleansing velocity based on tractive force theory. By applying a self-cleansing velocity equivalent to the critical shear stress of a sand particle, sedimentation can be reduced on non-rainy days. The amount of sewage changes according to the water use pattern of citizens. The design hourly maximum wastewater flow was considered as a representative value, and the velocity of this flow should be more than the self-cleansing velocity. This design method requires a steeper gradient than existing design criteria. Therefore, the existing sewer pipelines need to be improved and repaired accordingly. In this study, five types of improvement and repair methods that can maximize the use of existing pipelines and minimize the depth of excavation are proposed. The key technologies utilized are trenchless sewer rehabilitation and complex cross-section pipes. Trenchless sewer rehabilitation is a popular sewage repair method. However, it is complex because the cross-section pipes do not have a universal design and require continuous research and development. In an old metropolis with a combined sewer system, it is difficult to carry out excavation work; hence, the methods presented in this study may be useful in the future.

CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 - (Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity-)

  • 박노석;김성수;최종웅;성열붕;강문선
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.

정수처리를 위한 여과지의 역세척에 관한 연구 (A Study on Backwashing of Granular Fiters Used in Water Treatment)

  • 이정택;안종호;최근호
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • 한국습지학회지
    • /
    • 제9권1호
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF

소규모 오수처리를 위한 전기화학적 방법에 의한 대장균 소독에 관한 연구 (A Study on Escherichia Coli Disinfection by the Electrochemical Method for Small Sewerage System)

  • 박영식;정노성;김동석
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.441-447
    • /
    • 2007
  • This study was carried out to investigate the effect of electrochemical (EC) disinfection of artificial wastewater contaminated by Escherichia coli culture. Circulated batch type electrochemical disinfection system using three plates electrodes was used. Also, the several factors (pH, ORP, DO, temperature, current, conductivity) were measured in order to investigate the fundamental design factor in the EC disinfection system. It was demonstrated that the EC process was highly effective for wastewater disinfection. At the constant voltage, the disinfection efficiency was increased according to time. The disinfection efficiency and current increased as the increase of voltage. The variation of conductivity was a little related to the variation of CFU (colony forming units). The differences in disinfection efficiency according to the ice pack and the variation of electrodes were not occurred. The EC disinfection efficiency and current increased according to the increase of circulating flow rate.

전산유체해석기법을 이용한 용존공기부상공정의 유동해석 (Simulation study of DAF flotation basin using CFD)

  • 박병성;우성우;박성원;민진희;이우녕;유수남;전갑진
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.261-272
    • /
    • 2013
  • Algae boom (Red tide) in south coastal area of Korea has been appeared several times during a decade. If algae boom appears in the desalination plant, media filter and UF filter are clogged quickly, and the plant should be shutdown. In general, Algae can be removed from water by flotation better than by sedimentation, because of the low density of algal cell. The purpose of this study conducts the CFD simulation of DAF flotation basin to apply the design of the dissolved air flotation with ball filter in the Test Bed for SWRO desalination plant. In this study, Eulerian-Eulerian multiphase model was applied to simulate the behavior of air bubbles and seawater. Density difference model and gravity were used. But de-sludge process and mass transfer between air bubbles and seawater were ignored. Main parameter is hydraulic loading rate which is varied from 20 m/hr to 27.5 m/hr. Geometry of flotation basin were changed to improve the DAF performance. According to the result of this study, the increase of hydraulic loading rate causes that the flow in the separation basin is widely affected and the concentration of air is increased. The flow pattern in the contact zone of flotation basin is greatly affected by the location of nozzle header. When the nozzle header was installed not the bottom of the contact zone but the above, the opportunity of contact between influent and recycle flow was increased.

수질오염총량관리 계획수립의 개선방안에 관한 연구 (A Study on the Improvement Scheme of the Total Water Pollution Load Management Plan)

  • 김영일;이상진
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.977-981
    • /
    • 2006
  • In order to improve water quality in drinking water sources, Ministry of Environment (MOE) was implemented total water pollution load management (TWPLM) in all the major river basins. From the experience of the application of TWPLM, we could find some problems relating the target watershed, standard operating procedure (SOP) of establishment and implementation plan, water quality and flow rate, design flow, water quality model, margin of safety (MOS), and estimation of wasteload were found. The authors were reviewed ongoing TWPLM and presented the improvement schemes for a successful TWPLM. For the application of these suggestions, further detailed studies should be done to implement TWPLM in the future.

효율향상을 위한 폐수처리용 2 Vane 펌프 설계 최적화 (Design Optimization on 2 Vane Pump of Wastewater Treatment for Efficiency Improvement)

  • 김성;마상범;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.277-284
    • /
    • 2021
  • This paper deals with multi-objective optimization using response surface method to improve the hydraulic performances of a 2 vane pump for wastewater treatment. For analyzing the internal flow field in the pump, steady Reynolds-averaged Navier-Stokes equations were solved with the shear stress transport turbulence model as a turbulence closure model. The impeller and volute variables were defined in the shape of the 2 vane pump. The objective functions were set to satisfy the total head at the design flow rate as well as to improve the efficiency. The hydraulic performance of the optimally designed shape was verified by numerical analysis results.