• Title/Summary/Keyword: Design resistance

Search Result 3,780, Processing Time 0.038 seconds

Design of Poly-Fuse OTP IP Using Multibit Cells (Multibit 셀을 이용한 Poly-Fuse OTP IP 설계)

  • Dongseob kim;Longhua Li;Panbong Ha;Younghee Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.4
    • /
    • pp.266-274
    • /
    • 2024
  • In this paper, we designed a low-area 32-bit PF (Poly-fuse) OTP IP, a non-volatile memory that stores data required for analog circuit trimming and calibration. Since one OTP cell is constructed using two PFs in one select transistor, a 1cell-2bit multibit PF OTP cell that can program 2bits of data is proposed. The bitcell size of the proposed 1cell-2bit PF OTP cell is 1/2 of 12.69㎛ × 3.48㎛ (=44.161㎛2), reducing the cell area by 33% compared to that of the existing PF OTP cell. In addition, in this paper, a new 1 row × 32 column cell array circuit and core circuit (WL driving circuit, BL driving circuit, BL switch circuit, and DL sense amplifier circuit) are proposed to meet the operation of the proposed multbit cell. The layout size of the 32bit OTP IP using the proposed multibit cell is 238.47㎛ × 156.52㎛ (=0.0373㎛2) is reduced by about 33% compared that of the existing 32bit PF OTP IP using a single bitcell, which is 386.87㎛ × 144.87㎛ (=0.056㎛2). The 32-bit PF OTP IP, designed with 10 years of data retention time in mind, is designed with a minimum programmed PF sensing resistance of 10.5㏀ in the detection read mode and of 5.3 ㏀ in the read mode, respectively, as a result of post-layout simulation of the test chip.

Effect of Liquid Manure Source, Application Rate and Time on Agronomic Characteristics and Forage Yield of Winter Rye (가축분뇨의 종류, 시비량 및 시비시기가 호밀의 생육특성과 생산성에 미치는 영향)

  • Park, Jin-Gil;Kim, Jong-Duk;Kwon, Chan-Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.4
    • /
    • pp.227-232
    • /
    • 2006
  • This experiment was conducted to evaluate the effect of liquid manure source, application rate and time on the agronomic characteristics and forage yield of winter rye. The experimental design was a randomized complete block design. The treatments were : CFB150=chemical fertilizer(CF) 150 N as basal, CFS150=CF 150 N as split application (75+75), SLB150=swine liquid (SL) 150 N as basal, SLS150=SL 150 N as split application (75+75), SLB300=SL 300 N as basal, SLS150=SL 300 N as split application(150+150), CLB150=cattle liquid (CL) 150 N as basal, CLS150=CL 150 N as split awlication(75+75), CLB300=CL 300 N as basal, CLS150=CL 300 N as split application(150+150). Heading date of the plant was observed on the 17th of April fur both chemical fertilizer and swine liquid, and on the 16th of April for cattle liquid. Stay green of chemical fertilizer was higher than others because of high crude protein content. Leaf was darker in high nitrogen fertilizer treatments than low N treatments. However lodging resistance was poor as nitrogen fertilizer was increased. Dry matter (DM) content of rye at chemical fertilizer was lower than liquid manure. DM yield of chemical fertilizer treatments were highest among the fertilizer source. However, DM yield of rye with application was all most same at different N application methods. The crude protein (CP) content and yield for chemical fertilizer was significantly higher than liquid manure. CP yield using split application was higher by 16% and 28%, compared to basal application. Based on the results of this study, forage production of liquid manure was lower, compared to chemical fertilizer. And split application was superior to basal application forage and protein yields, and high protein.

Microleakage of endodontically treated teeth restored with three different esthetic post and cores (심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구)

  • Park, Ji-Geun;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)

A Dynamic Behavior Evaluation of the Curved Rail according to Lateral Spring Stiffness of Track System (궤도시스템의 횡탄성에 따른 곡선부 레일의 동적거동평가)

  • Kim, Bag-Jin;Choi, Jung-Youl;Chun, Dae-Sung;Eom, Mac;Kang, Yun-Suk;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.517-528
    • /
    • 2007
  • Domestic or international existing researches regarding rail damage factors are focused on laying, vehicle conditions, driving speed and driving habits and overlook characteristics of track structure (elasticity, maintenance etc). Also in ballast track, as there is no special lateral spring stiffness of track also called as ballast lateral resistance in concrete track, generally, existing study shows concrete track has 2 time shorter life cycle for rail replacement than ballast track due to abrasion. As a result of domestic concrete track design and operation performance review, concrete track elasticity is lower than track elasticity of ballast track resulting higher damage on rail and tracks. Generally, concrete track has advantage in track elasticity adjustment than ballast track and in case of Europe, in concrete track design, it is recommended to have same or higher performance range of vertical elastic stiffness of ballast track but domestically or internationally review on lateral spring stiffness of track is very minimal. Therefore, through analysis of service line track on site measurement and analysis on performance of maintenance, in this research, dynamic characteristic behaviors of commonly used ballast and concrete track are studied to infer elasticity of service line track and experimentally prove effects of track lateral spring stiffness that influence curved rail damage as well as correlation between track elasticity by track system and rail damage to propose importance of appropriate elastic stiffness level for concrete and ballast track.

  • PDF

FEA estimates of margin design in all ceramic crowns (완전 도재관을 위한 지대치 형성시 변연 형태에 따른 응력 분포의 유한요소법적 비교)

  • Han, Sang-Hyun;Cho, Jung-Hyeon;Lee, En-Jung;Jeong, Suk-In;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Statement of problem: Over the past decade, increased demand for esthetically pleasing restorations has led to the development of all-ceramic systems. Recent reports suggest that the all-ceramic crowns have excellent physical properties, wear resistance, and color stability. In addition, numerous ceramics have excellent biocompatibility, a natural appearance, and improved physical bonding with resin composite luting agents. However, the brittle nature of ceramics has been a major factor in their restriction for universal usage. Functional occlusal loading can generate stress in the luting agent, and the stress distribution may be affected by the marginal geometry at the finish line. Tooth preparation for fixed prosthodontics requires a decision regarding the marginal configuration. The design dictates the shape and bulk of the all ceramic crowns and influences the fit at the margin. Purpose: The purpose of this study was to evaluate the stress distribution within marginal configurations of all- ceramic crowns (90-degree shoulder, 110-degree shoulder, 135-degree shoulder). Material and methods: The force is applied from a direction of 45 degrees to the vertical tooth axis. Three-dimensional finite element analysis was selected to determine stress levels and distributions. Results and conclusion: The result of stress level for the shoulder marginal configuration was more effective on stress distribution at 135-degree shoulder margin. But the stresses concentrated around at 135-degree shoulder margin. The stress decreased apically at the surface between cements and alumina core, and increased apically at the surface between alumina core and veneering porcelain.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Lateral Strength of Double-Bolt Joints to the Larix Glulam according to Bolt Spacing (볼트 간격에 따른 낙엽송 집성재 이중 볼트접합부의 전단강도)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • The lateral strength test of bending type was done to investigate the lateral capacity of the double bolt connection of domestic larix glulam according to bolt spacing. In the shear specimen, which is bolted connection in the inserted plate type, the hole of bolt was made, changing the diameter of bolt (12 mm and 16 mm), the number of bolt (single bolt : control and double bolt), the direction of bolt row (in parallel to grain : Type-A and in perpendicular to grain : Type-B) and the bolt spacing (Type-A : 4 d and 7 d and Type-B : 3 d and 5 d). Lateral capacity and failure mode of bolt connection were compared according to conditions. In prototype design (KBCS, 2000), the reduction factor of the allowable shear resistance that the bolt spacing is reduced was calculated. The results were as follows. 1) Bearing stress per bolt in the single and double bolt connection of Type-A was directly proportional to bolt diameter and bolt spacing. Bearing stress of Type-B decreased as bolt diameter was increased, and decreased by 2~10% when bolt diameter was increased. 2) In the single bolt connection and the double bolt connection of Type-A, the splitted failure was formed in the edge direction. When the bolt spacing was 3 d in Type-B, bolt was yielded more in the part of tension than in the part of compression, and the splitted failure started at the bolt in the part of tension. In the 5 d spacing specimen, the bolt in the part of tension was yielded similarly to bolt in the part of compression, and the splitted failure started in the part of compression. 3) In the prototype design, the reduction factor was calculated by non-dimensionizing the yielding load in the standard of bolt spacing (Type A : 7 d and Type B : 5 d). In 12 mm bolt connection, the reduction factor of bolt spacing 4 d (type-A) and single bolt connection was 0.87 and 0.55, respectively, and the reduction factor of bolt spacing 3 d (Type-B) and single bolt connection was 0.91 and 0.55, respectively. In 16 mm bolt connection, the reduction factor of bolt spacing 4 d (type-A) and single bolt connection was 0.96 and 0.76, respectively, and the reduction factor of bolt spacing 3 d (Type-B) and single bolt connection was 0.91 and 0.77, respectively.

Behavior Analysis of Concrete Structure under Blast Loading : (I) Experiment Procedures (폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (I) 실험수행절차)

  • Yi, Na Hyun;Kim, Sung Bae;Kim, Jang-Ho Jay;Choi, Jong Kwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.557-564
    • /
    • 2009
  • In recent years, there have been numerous explosion-related accidents due to military and terrorist activities. Such incidents caused not only damages to structures but also human casualties, especially in urban areas. To protect structures and save human lives against explosion accidents, better understanding of the explosion effect on structures is needed. In an explosion, the blast overpressure is applied to concrete structures as an impulsive load of extremely short duration with very high pressure and heat. Generally, concrete is known to have a relatively high blast resistance compared to other construction materials. However, information and test results related to the blast experiment of internal and external have been limited due to military and national security reasons. Therefore, in this paper, to evaluate blast effect on reinforced have concrete structure and its protective performance, blast tests are carried out with $1.0m{\times}1.0m{\times}150mm$ reinforce concrete slab structure at the Agency for Defence Development. The standoff blast distance is 1.5 m and the preliminary tests consists with TNT 9 lbs and TNT 35 lbs and the main tests used ANFO 35 lbs. It is the first ever blast experiment for nonmilitary purposes domestically. In this paper, based on the basic experiment procedure and measurement details for acquiring structural behavior data, the blast experimental measurement system and procedure are established details. The procedure of blast experiments are based on the established measurement system which consists of sensor, signal conditioner, DAQ system, software. It can be used as basic research references for related research areas, which include protective design and effective behavior measurements of structure under blast loading.

Effects of Edged Curve Angle of Rotary Blade on Entwining Spreaded Rice Straw in Paddy (볏짚 시용(施用) 답(畓)의 Rotary 경운시(耕耘時) 날의 궤적(軌跡) 진입각(進入角)이 볏짚 감김에 미치는 영향(影響))

  • Yi, Woon Young;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.1
    • /
    • pp.103-112
    • /
    • 1986
  • This study was carried out to prevent the entwining of rice straw on rotary shaft and blade where rice straw was spreaded on paddy field as an organic source before rotary tilling. The rotary tillage was conducted in the paddy field having the soil moisture contents of 30%, 39%, 59% in dry basis and spreaded rice straw (450kg/10a) of 30cm, 45cm, 90cm length with the edged curve angles of rotary blade of $30^{\circ}$, $40^{\circ}$, $50^{\circ}$, $55^{\circ}$ at Yuseung area. And the test were performed on the plot which has width of 30cm and 5cm length and the quantity of entwined rice straw was analized. The test results were summarized as the followings. 1. Entwining phenomenon of rice straw was decreased as the blade edged curve angle increased. The edged curve angle of rotary blade must be determind by considering the characteristics of soil cutting resistance, tilling torque and entwining phenomenon of rice straw. But according to the entwining phenomenon of rice straw only, the edged curve angle of rotary blade should be bigger than $55^{\circ}$ for design. 2. Amount of entwining rice straw was minimized when soil moisture contents was 30 percent (d. b.). It would be better that rotary tillage is performed when soil moisture contents is lower than 30 percent in dry basis. 3. Amount of entwining rice straw was minimized when the length of rice straw was 30cm with $55^{\circ}$ edged curve angle. Therefore, it would be better to chop rice straw as 30cm. 4. Entwining phenomenon of rice straw was decreased as the forward speed decreased. To decrease the entwining rice straw, rotary tillage should be done with forward fist gear (0.35m/s).

  • PDF