• Title/Summary/Keyword: Design of sewer system

Search Result 78, Processing Time 0.017 seconds

Hydraulic analysis of design alternatives to improve an industrial water distribution system (공업용수 배수관망시스템을 개선하기 위한 설계 대안의 수리해석)

  • Lim, Seong-Rin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.97-106
    • /
    • 2015
  • A CCTV inspection method has been widely used to assess sewer condition and performance, but Korea lacks a proper decision support system for prioritizing sewer repair and rehabilitation (R&R). The objective of this paper is to introduce the results that we have developed in the Sewer Condition Assessment and Rehabilitation Decision-making (SCARD) Program using MS-EXCEL. The SCARD-Program is based on a standardized defect score for sewer structural and hydraulic assessment. Priorities are ranked based on risk scores, which are calculated by multiplying the sewer severity scores by the environmental impacts. This program is composed of three parts, which are decision-making for sewer condition and performance assessment, decision-making for sewer R&R priority assessment, and decision-making for optimal budget allocation. The SCARD-Program is useful for decision-makers, as it enables them to assess the sewer condition and to prioritize sewer R&R within the limited annual budget. In the future, this program logic will applied to the GIS-based sewer asset management system in local governments.

Comparison of Characteristics of Nonpoint Source Pollution from Separate and Combined Sewer System (합류식 월류수와 분류식 우수유출수의 비점오염물질 유출특성 비교)

  • Shin, Min Hwan;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.97-106
    • /
    • 2017
  • In this study, the characteristics of nonpoint source pollutant loads from separate sewer overflow (SSO) and combined sewer overflow (CSO) were evaluated during 2016 in Namyangju city, Korea. Five rainfall events were monitored during 2016 with ranging from 14.5 mm to 121.5 mm. The runoff ratio of CSO was higher than that of SSO because only design volume of maximum sanitary sewer ($1Q_h$) was transported and treated and $2Q_h$ was overflowed to waterbody during rainy day although combined sewer system was designed to transport $3Q_h$ to treatment system. The event mean concentrations (EMCs) and pollutant loads from CSO were higher than those from SSO. BOD and COD of CSO, and TOC and TN of SSO represented distinct first flush phenomena. The inadequate management in combined sewer system from which the untreated $2Q_h$ from CSO was overflowed to waterbody during rainy day could influence on high pollutant loads and first flushing. Treating $2Q_h$ from CSO, source control such as low impact development, and treating outflow from SSO were strongly recommended to control non-point source pollution in urban area.

Effect of Rainfall Design Frequency Determination on the Design of Storm Sewer System (강우 확률년수의 설정이 우수관거 설계에 미치는 영향)

  • Lee, Cheol-kyu;Hyun, In-hwan;Dockko, Seok;Kim, Hyung-jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.647-654
    • /
    • 2005
  • Recently, the economic losses caused by inundation are increasing due to the urbanization and industrialization, i.e., intensive land utilization and concentration of population and properties. It is regarded that the role of the storm sewer systems in urban areas becomes more important as one of the effective countermeasures for reducing the inundation losses. In this study, the effects of rainfall design frequency enhancement on the construction cost of the storm sewer systems were analyzed by increasing the design frequency from the present design frequency of the sewer systems, which is 5~10 years, to 15 years, 20 years and 30 years. The change rate functions of the design discharge and construction cost based on the various design frequencies were derived by regression analysis. According to the analysis, change the rate of design discharge at 15, 20, 30 years rainfall design frequencies were increased by 10%, 17.1%, and 27.2%, respectively, when compared to that at 10 year frequency. Furthermore, it was found that by increasing the design frequency from 10 years to 15 years, 20 years and 30 years, the construction costs were increased by 5.0%, 8.0% and 12.4%, respectively. Finally, their reliabilities need to be tested by applying the rate functions to the real storm sewer districts.

A combined sewer design method using tractive force considering wastewater flow on non-rainy days and its application for improvement methods of sewer (청천시 오수량을 고려한 합류식 하수도 소류력 설계법과 이를 활용한 하수관거 개보수방안)

  • Ji, Hyon Wook;Yoo, Sung Soo;Song, Homyeon;Kang, Jeong-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.211-220
    • /
    • 2020
  • When domestic sewage and rainwater runoff are discharged into a single sewer pipe, it is called a "combined sewer system." The sewage design standards in Korea specify the flow velocity based only on the volume of rainfall; therefore, sedimentation occurs on non-rainy days owing to the reduced flow rate and velocity. This sedimentation reduces the discharge capacity, causes unpleasant odors, and exacerbates the problem of combined sewer overflow concentration. To address this problem, the amount of sewage on non-rainy days, not just the volume of rainfall, should also be considered. There are various theories on sedimentation in sewer movement. This study introduces a self-cleansing velocity based on tractive force theory. By applying a self-cleansing velocity equivalent to the critical shear stress of a sand particle, sedimentation can be reduced on non-rainy days. The amount of sewage changes according to the water use pattern of citizens. The design hourly maximum wastewater flow was considered as a representative value, and the velocity of this flow should be more than the self-cleansing velocity. This design method requires a steeper gradient than existing design criteria. Therefore, the existing sewer pipelines need to be improved and repaired accordingly. In this study, five types of improvement and repair methods that can maximize the use of existing pipelines and minimize the depth of excavation are proposed. The key technologies utilized are trenchless sewer rehabilitation and complex cross-section pipes. Trenchless sewer rehabilitation is a popular sewage repair method. However, it is complex because the cross-section pipes do not have a universal design and require continuous research and development. In an old metropolis with a combined sewer system, it is difficult to carry out excavation work; hence, the methods presented in this study may be useful in the future.

Development of Optimal Design Simulation Model for Least Cost Urban Sewer System Considering Risk (I) (위험도를 고려한 최소비용 도시우수관망 설계의 최적화 모형개발 (I): 모형의 개발과 시험유역의 적용)

  • Jang, Suk-Hwan;Park, Sang-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.12 s.161
    • /
    • pp.1021-1028
    • /
    • 2005
  • This study purpose to develop simulation model of optimal design condition of urban storm sewer system considering risk. Urban Storm Sewer Optimal Design Model(USSOD) can compute pipe capacity, pipe slope, crown elevation, excavation depth, risk and return cost in the condition of design discharge. Rational formula is adopted for design discharge and Manning's formula is used for pipe capacity. Discrete differential dynamic programming(DDDP) technique which is a kind of dynamic programming(DP) is used for optimization and first order second moment approximation method and uncertainty analysis is also for developing model. USSOD is applied to hypothetical drainage basin to test and verify, which resulted economical and efficient design in urban drainage sewer system.

Inundation simulation in a urban drainage basin considering tidal stage effect (조위의 영향을 고려한 도심지 배수유역에서의 범람모의)

  • Kim, Dae Geun;Choi, Kyung Soon;Koh, Young Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.711-717
    • /
    • 2009
  • In this study, SWMM model is used to reproduce the main storm sewer system located in the Nae-Hang drainage basin of the Mokpo city and keep track of flood discharge. Given the outlet of the reaches border the coastline, this paper has taken the dual-drainage approach to perform inundation simulation, considering both the overflows and inflows at the manholes of the sewer system, and at the same time, taking the impacts of tidal stage into consideration. The following conclusions are reached in this study: First, when planning lowland sewer system alongside the coastline or the riverside, the tidal stage or flood stage need to be considered in the planning and design processes. Second, an analysis that fails to consider overflow and inundation at the manholes may overestimate inundation depth of the flooded area. In other words, in order to estimate flood discharge and flood stage in a lowland storm sewer system, it is desirable to analyze the conveyance capacity of storm sewer system and simulate overflow and inundation at the manholes at the same time.

Assessment of Design Method about Sanitary Sewer Network according to RDII and Established Scenario (RDII발생 및 기존 시나리오에 따른 오수간선 네트워크 설계방법 검토)

  • Kim, Jungryul;Oh, Jeill
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.4
    • /
    • pp.367-374
    • /
    • 2016
  • In this study, the RDII impact on sewer designing in the upstream monitoring area (A site) was considered. Based on the long-term (1/1/2011~12/31/2011) rainfall and flow data consisting of 10-min interval sampling in the nearby design area (B site), the maximum RDII/DWF ratio was selected. The sewer network system at B site was evaluated by the Manning equation. Scenario 1 considering the hourly maximum flow with respect to the flow velocity showed that none of the sewer pipes satisfied the minimum flow velocity condition (0.6 m/s), and 40 pipes did not achieve half of the velocity condition. In scenario 2 considering I/I, 1 the pipes satisfied 0.6 m/s, and 35 pipes showed 0.3 m/s. Scenario 3 reflected the effect of RDII. Velocities in 26 pipes were less than 0.3 m/s, and 4 pipes satisfied the velocity condition. With respect to the allowance rate, 17 pipes were shown to have more than 99%, and none of the pipes satisfied less than 95% of the allowance rate in scenario 1. In scenario 2, 17 Ed: Per the Table pipes showed more than 99% and one pipe showed less than 95%. In scenario 3, 16 pipes showed more than 99% of the allowance rate, and 19 pipes showed less than 95%. Based on these results, it is predicted that deposition would occur due to the slow flow velocity; however, capacity would not be a problem.

Generating Alternative Sewers Based on GIS and Simulation Technique (GIS 및 Simulation 기법에 의한 하수도관거 대안 생성)

  • 김형복;김경민
    • Spatial Information Research
    • /
    • v.5 no.2
    • /
    • pp.185-194
    • /
    • 1997
  • Spatial decision support systems(SDffi), a new class of decision support system(DSS), result from the melding together of GIS and DSS, Planning support systems(PS5) add more advanced spatial analysis functions than GIS and intertemporal functions to the functions of SDSS. This paper reports the development of a planning support system providing a framework that facilitates urban planners and civil engineers in conducting coherent deliberations about the generation of satisficing sewers. 1he planning support system for the generation of satisficing sewers(PS5/GSS) was designed from the understanding that land use and development drive the demand for storm and sanitary sewers. Through four stages of supply, demand, alternative generation, and evaluation, PSS/GSS integrates basic planning, preliminary design, and engineering design of sewer. GIS and graphic user interface are excellent toolboxes for designing sewer networks, estimating the quantity of wastewater, and showing generated alternative sewers. A sewer model using simulation tedmique can generate an initial sewer. Users can define alternative sewers by the direct manipulation of sewer networks or by the manipulation of parameters in the sewer model. The sewer model evaluates the performance of the user defined alternatives.

  • PDF

A Study of Sewer Layout to Control a Outflow in Sewer Pipes (우수관거 흐름 제어를 위한 관망 설계에 관한 연구)

  • Kim, Joong-Hoon;Joo, Jin-Gul;Jun, Hwan-Don;Lee, Jung-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Most developed models are designed to determine pipe diameter, slope and overall layout in order to minimize the cost for the design rainfall for the optimal sewer layout. However, these models are not capable of considering the superposition effect of runoff hydrographs in the sewer pipes. The flow characteristics in the sewer pipes, such as the sewer layout, pipe diameter and slope, vary according to the design of the sewer system. In particular, when the sewer network is modified, the shapes of the runoff hydrographs in the sewer pipes also change because of the superposition effect. In this study, the sewer layout is designed to control and distribute the flows in the sewer pipes, while considering the runoff superposition effect, in order to reduce the inundation risk at each junction. This is accomplished by separating the inflows that enter into each junction by changing the way in which pipes are connected between junctions. And this model combines SWMM (Storm Water Management Model) to perform the hydraulic analysis for the flows in the sewer network. The current sewer layout was modified to minimize the peak outflow at outlet in Garak basin, Seoul, South Korea. As the results, the peak outflows at the outlet were decreased by approximately 20% for the design rainfall during 30 minutes and the total overflows were also decreased for the excessive rainfalls.

Sewerage rehabilitation strategy based on sewer capacity evaluation (하수관거 통수능 검토를 통한 관거 개선방안 연구)

  • Ryu, Jaena;Oh, Jeill;Oh, Sukho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.47-55
    • /
    • 2009
  • Sewers are important national infrastructure and play an essential part by handling both wastewater and stormwater to minimise problems caused to human life and the environment. However, they can cause urban flooding when rainfall exceeds the system capacity. Sewer flooding is an unwelcome and increasingly frequent problem in many urban areas, and its frequency will increase over time with urbanisation and climate change. Under current standards, sewers are designed to drain stormwater generated by up to 10 year return period storms, but data suggests that many in practice have been experienced flooding with exceeding system capacity under increased storm events. A large number of studies has considered upgrading or increasing the design standard but there are still lack of information to propose a suitable return period with the corresponding system quantity to achieve. A methodology is required to suggest a proper level of standard within a suitable sewerage rehabilitation planning that can avoid the exceedance problem. This study aimed to develop a methodology to support effective sewer rehabilitation that could prevent urban flooding mainly resulted from the exceedance of existing storm sewer system capacity. Selected sewerage rehabilitation methods were examined under different storm return periods and compared to achieve the best value for money.