• Title/Summary/Keyword: Design approval test

Search Result 38, Processing Time 0.028 seconds

Contribution of thermal-hydraulic validation tests to the standard design approval of SMART

  • Park, Hyun-Sik;Kwon, Tae-Soon;Moon, Sang-Ki;Cho, Seok;Euh, Dong-Jin;Yi, Sung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1537-1546
    • /
    • 2017
  • Many thermal-hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor) design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop) has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium) safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test) facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant) performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test) facility to evaluate the safety injection performance and to validate the thermal-hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux) test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop) facility to construct a database from the $5{\times}5$ rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio) model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems (가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구)

  • Son, Bong-Sei;Kim, Hee-Woo
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2007
  • This study aims to investigate, review, and summarize the definition, development, and applications of "percent agent in pipe", "percent of agent in pipe" which is used as a key factor in testing and evaluating the performance of gaseous fire extinguishing agents, including Halon 1301 and $CO_2$. This study also analyzes and compares the local and international standards on testing and evaluating the performance of gaseous fire extinguishing systems, as well as the results of system performance tests conducted as a part of performance evaluation and approval programs for gaseous fire extinguishing systems, especially, Korean Gaseous Fire Extinguishing System Performance Approval Program called KFI Approval. Percent agent in pipe was defined first in NFPA 12A, Standard on Halon 1301 Fire Extinguishing Systems, dating back to the 1970's. After the phaseout of Halon 1301 systems in 1994 in the developed countries, the percent agent in pipe has been widely used in Halon 1301 alternative clean agent fire extinguishing systems, both halocarbon clean agent systems and inert gas clean agent systems, as an essential criterion to assure the system design accuracy, determine the limitations and performance of a system, and to predict the system performance results accurately, especially, in association with their system flow calculations. Underwriters Laboratories has their own standards such as UL 2127 and 2166 applying percent agent in pipe in testing and evaluating the performance of clean agent fire extinguishing systems. As a part of a system performance test and approval program called KFI Approval System, Korea also has started to apply the percent agent in pipe as a key factor to test, evaluate, and approve the performance of gaseous fire extinguishing systems, including both high and low pressure $CO_2$ systems, from the early 2000's. This study outlines and summarizes the relevant UL and KFI standards and also describes the actual test resultant data, including the maximum percents of agent in pipe for gaseous fire extinguishing systems. As evidenced in lots of tests conducted as a part of the system performance test and approval programs like KFI Approval System, it has been proven that the percent agent in pipe may work as a key factor in testing, evaluating, and determining the limitations and performance of gaseous fire extinguishing systems, especially compared with the hydraulic flow calculations of computer design programs of gaseous fire extinguishing systems, and will remain as such in the future. As one thing to note, however, there are some difficulties in using the unified percent agent in pipe to determine the maximum lengths of pipe networks for gaseous fire extinguishing systems, because the varying definitions used by some of the flow calculations (not in accordance with NFPA 12A definition) make it impossible to do any direct comparison of pipe lengths based on percent agent in pipe.

Dynamometer Test Procedure of Metal Brake Pad for Part 25 Aircraft (수송류 항공기용 금속계 제동패드의 다이나모시험 절차)

  • Min-ji Kim;Kyung-il Kim;Kyung-taek Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.821-827
    • /
    • 2023
  • In this study, the aircraft technical standards of the Korea and the United States were analyzed to derive the dynamometer test procedure required to prove the compatibility for flight test certification of the metal brake pad for transport aircraft. Since the design modification of the brake systems is classified as a major change, the STC(Supplemental Type Certificate) and the PMA(Parts Manufacturer Approval) are required. In accordance with the TSO-C135a, the technical standard order for brake system in the United States, the design landing-stop test, accelerate-stop test, and most severe landing stop test were selected among the test items for flight test. The conditions for the dynamometer test are determined according to the specifications provided by aircraft manufacturer, and the brake pad condition, deceleration, and the number of test are defined according to the TSO-C135a.

A Study on DC-DC Converter Development for LRT Wireless Power Supply

  • Han, Young-Jae;Lee, Su-Gil;Lee, Young-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.179-184
    • /
    • 2018
  • In this paper, we have proposed the development of DC-DC converter for LRT power supply. First of all, we have studied converter technology, main functions and characteristics were determined. In also, the converter design was carried out to meet the system design conditions. Based on this design, converter simulation is performed to enable stable charging and discharging of the vehicle system. We have performed the Light-load test according to charge mode, discharge mode. As a result, the manufactured converter performance was verified through the load test, and it's stability was confirmed.

Development of Full-scale Airframe Durability Test Technique (항공기 전기체 내구성시험 기법 개발)

  • Shul, Chang-Won;Yang, Myung-Seog;Lee, Kee-Bhum;Jung, Jae-Kwon;Kang, Hui-Won;Lee, Kyung-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.117-125
    • /
    • 2004
  • This paper describes the test technique for the full-scale airframe durability test according to the military handbook(MIL-HDBK-1530) and ASIP(Aircraft Structure Integrity Program) to evaluate structural integrity and to obtain basic data for IPA(Initial Production Approval) of the Korean advanced trainer(T-50). This paper covers the full-scale airframe floating setup technique, the optimized test load simulation method, test rig design technique, test setup design and installation techniques, test safety device design and operation technique, and durability test results. As 1st life durability test was successfully performed, it was confirmed that this method is available in a full-scale airframe structural test.

A Study on the Design of Electrolysis Power for the Laboratory Test of BWTS (선박평형수 처리시스템의 랩테스트를 위한 전기분해전원 설계에 관한 연구)

  • Kim, Tae-O;Lee, Sun-Kwon;Joo, Hui-Dong;Kang, Gyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1181-1182
    • /
    • 2011
  • 본 논문은 선박에서 발생하는 여러 해양오염원 중에서 선박평형수에서 야기되는 해양생태계의 오염 문제를 해결하기 위하여 사용되는 방법중에서 가장 효율적인 방식인 전기분해 방식에 대한 시스템 설계에 관한 연구로서, IMO의 밸러스트수 관리시스템 승인을 받기 위한 첫 번째 단계인 Basic Approval(랩테스트)을 받기 위한 전기분해 전원장치를 설계하고 시뮬레이션으로 검증하였다.

  • PDF

APPLICATION OF PERFORMANCED BASED DESIGN IN FIRE PROTECTION ENGINEERING

  • Cha, David S.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.423-438
    • /
    • 1997
  • Today's building and fire prevention codes are mostly prescriptive. Prescriptive codes are based on major fires in earlier years that created a need for specific building provision. These codes provide a minimum level of safety. As the general and engineering uses of computers have increased over the years, so has use of computers in the fire protection engineering. This has allowed fire protection engineers to develop alternative approaches to solve today's fire protection problems or to evaluate the performance of a specific fire safety goal. A performance based approach to building and fire codes involves the following: 1) identifying specific goals, such as, safely getting out of the building in 10 minutes, 2) obtain conceptual approval from authorities, 3) define performance level, 4) develop design solutions and identify tools such as, fire tests, models, or methods, to demonstrate that a design will meet the fire protection objective 5) test solutions, 6) present test method and results to the authorities. Some people in the fire protection community consider this to be nothing more than an intellectual exercise, while the others view it as a way to reduce expenses on large project$^4$ Others in fire protection community view this as a way to refine the design process to design fire protection systems to better protect the fire hazards. This paper will focus on application of these tools, specifically computer fire models, to actual cases such as: design of a smoke control system heat transfer analysis and egress of building occupants during potential fires.

  • PDF

A Study on the Verification of Design Compatibility for a Europe Type Automatic Coupler Head according to TSI Certification Standards (TSI 인증기준에 따른 유럽 표준형 자동복합연결기 헤드의 설계적합성 검증 연구)

  • Min, Kyeong Bin;Park, Jin Kyu;Kang, Ji Sung;Kim, Ki Nam
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • The type approval system of the railway safety law, which was enforced in 2014, has been preferentially applied to the field of railway vehicles. The type approval system addresses railway vehicles and railway constituents. Unlike the previous system, it requires serial verification stages divided, in consecutive order, into verification of design compatibility and conformity and type test. These stages are in accord with international certification systems including TSI certification of the European commission. This study has been carried out to find and meet the design requirements for a coupler head, which is a part of the automatic coupler system; requirements were drawn from TSI and technical specifications that are subordinate to the domestic railway approval system. Through this study, it has been found that there exist 34 design requirements to acquire a complete coupler head. Among those requirements, 32 were verified by document inspection and two were able to be verified by performing FEA and gathering range analysis data.

Reverse Engineering Procedure of Metal Brake Pad for Part 25 Aircraft (수송류 항공기용 금속계 제동패드의 역설계 절차)

  • Min-ji Kim;Kyung-il Kim;Kyung-taek Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.621-628
    • /
    • 2023
  • This study derived a reverse engineering procedure for verifying the design identity of original parts and developed parts for PMA(Parts Manufacturer Approval) and STC(Supplemental Type Certificate) of metal brake pads for transport aircraft, which are critical parts among aircraft parts and equipment. In Korea, the regulations for reverse engineering procedures are regulated by the Parts Manufacturer Approval Guidelines, and in the United States, AC No. 21. 303-4. In the reverse engineering for the brake pad, the detailed procedures for each component were determined by selecting verification test items to confirm identity based on sample quantity, dimensional tolerance, mechanical property measurement, material, weight and volume characteristics for each component. In addition, as a result of analyzing the regulation of Korea and United States, in the case of Korea, it is necessary to establish technical standards for braking systems for transport aircraft and regulations related to flight tests.

Development of Wide Prestressed Concrete Sleeper for Asphalt Concrete Track (아스팔트 콘크리트 궤도용 광폭 PSC침목 개발)

  • Bae, Young-Hoon;Lee, Seong-Hyeok;Kim, Eung-Rok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.34-42
    • /
    • 2018
  • In order to minimize the deformation of asphalt concrete track(ACT) and ensure the structural safety, a wide type concrete sleeper is necessary to distribute vehicle loading and reduce the exposure of the asphalt roadbed. In this research, the wide prestressed concrete(PSC) sleeper for ACT was developed through the shape design and the structural safety was reviewed using finite element analysis. Furthermore, static test, dynamic test and fatigue test were carried out according to EN13230-2 to verify the design appropriateness of the wide PSC sleepers for ACT. The performance test showed that the developed wide PSC sleeper for ACT meets all the performance requirements by European standard.