• Title/Summary/Keyword: Design Test Evaluation

Search Result 2,817, Processing Time 0.029 seconds

A Study on the Fatigue Test and Performance Evaluation for Linear Motion Rolling Bearing (직선운동베어링 성능평가방법의 표준화 및 내구성 시험에 관한 연구)

  • 김태범;김동길;이상조;김익수;이위로;이동규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1270-1274
    • /
    • 2003
  • The objective of this paper is to introduce the standard of evaluation methods and fatigue test for linear motion rolling bearing. In particular, attention well be given to the list of evaluation and fatigue results in this paper. The life of a linear motion rolling bearing is given by the length of distance covered between the connection parts before the first evidence of fatigue develops in the material of one of the raceways of rolling elements. The main factors that contribute to fatigue failures include: Number of load cycles experienced; Range of stress experienced in each load cycle; Mean stress experienced in each toad cycle; Presence of local stress concentrations.

  • PDF

Comparative Analysis of the Patterns for Men's Jean Pants by 3D Virtual Garment Simulation Evaluation (3차원 가상착의에 의한 남성 Jean Pants 패턴 비교 분석)

  • Hong, Eun-Hee;Uh, Mi-Kyung;Kim, Kyung-A
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.2
    • /
    • pp.223-237
    • /
    • 2015
  • This study is to compare the pattern making methods of men's jeans and to analyze sizes of parts while also evaluating the appearance and fit according to a 3D virtual garment simulation. Five types of patterns are selected for the analysis. For the appearance evaluation, the study conducted a virtual clothing simulation, created a perspective drawing, and applied Clothing pressure to each test outfit. First, according to the pattern comparisons, A and D had the shortest crotch length, while B had the longest; B had the narrowest crotch width, while C had the widest; C had the greatest waist circumference, and B had the smallest; C had the greatest knee and hem circumference, while E had the smallest. Second, according to the appearance evaluation, E pants had the highest rating overall for the waist, crotch, knee, and hem comfort; A pants had the highest rating for the yoke line end and placement; and C pants had the highest rating for the side seam line. According to the correlation analysis, ease of the waist, hips, hem and thighs were important factors (in that order) in determining the overall appearance of the jean pants.

  • PDF

Evaluation of Design Parameters for Axial Bearing Capacity of Drilled Shafts by Bi-directional Loading Tests (양방향말뚝 재하시험을 통한 현장타설말뚝의 연직지지력 설계정수 산정)

  • Jung, Gyung-Ja;Cho, Chong-Suck;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.574-584
    • /
    • 2006
  • Bi-directional loading test data are available to evaluate the design parameters which reflect the characteristics of a construction method and the variations of ground at the site where drilled shafts are installed. The method to obtain the design parameters of a real bridge by hi-directional loading test was introduced. The plans of multi-level testing and installation of measuring instruments should be made according to the rough estimation of axial bearing capacity, the length of pile, and the construction method. While the relationship between end bearing resistance and displacement was obtained directly from the hi-directional loading test, the relationship between unit side resistance and displacement was calculated through the measuring values. 1% displacement of pile diameter was adopted as the criteria of failure for ultimate resistance. As the settlement of pile head at the total ultimate bearing capacity obtained from these method was less than 1.5 % of pile diameter, this method was conservative to use in the field.

  • PDF

The Wind Pressure Evaluation on Exterior Wall for High-rise Buildings (고층구조물 외벽의 내풍설계를 위한 풍압평가)

  • Lee Kyu-Ung;Kim Jae-Ung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.63-70
    • /
    • 2005
  • For using narrow site effectively, recently constructions of high-rise buildings have been increased. High-rise buildings are mainly governed by wind loads. Since wind flow Is vaned irregularly, the experimental method such as wind tunnel test is used to evaluate real wind loads. In this study, it is intended to estimate design wind pressure and amounts of material of cladding by AIK recommendations and wind tunnel test. Also, this study includes the investigation of reliability, suitability and economical efficiency in design of cladding of buildings by AIK recommendations and wind tunnel test by comparing and examining various results. Finally, it is concluded that not only AIK recommendations but also wind tunnel test should be considered to get the reasonable wind pressure acting on the cladding of high-rise buildings.

  • PDF

Seismic Performance Evaluation of Shear-Critical R/C Bridge Piers Retrofitted with Fiber Sheets (섬유 보강된 휨전단 RC교각의 내전성능 평가)

  • 송호진;정영수;김용곤;이은희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.195-202
    • /
    • 2002
  • Lap splices of longitudinal reinforcement steels were practically located in the potential plastic hinge region of most bridge columns that were constructed before the 1992 seismic design provision of Roadway Bridge Design Specification in Korea. The objective of this research is to evaluate the seismic performance of shear-critical reinforced concrete(RC) bridge piers with poor detailing of the starter bars in the plastic hinge region, and to develop the enhancement scheme of their seismic capacity by retrofitting with fiber composites. Seven test specimens in the aspect ratio of 2.5 were made with three confinement ratios and two types of lap splices. Quasi-static test was conducted in a displacement-controlled test mode. A significant reduction of displacement ductility ratios were observed for test columns with lap splices of longitudinal steels.

  • PDF

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.3
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

Performance Test and Evaluation of Ship Exhaust Huffier (선박용 소음기 성능 시험 및 평가)

  • Kim, Bong-Ki;Kim, Sang-Ryul;Kim, Hyun-Sil;Shin, Min-Chol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.158-163
    • /
    • 2008
  • Muffler design in the exhaust system is critical to provide for low noise in shipboard spaces. In an attempt to effectively design the low noise muffler, it is important to evaluate the performance of the muffler considering not only the noise, but also pressure drop as well. For this purpose, a test system of large exhaust muffler for ship propulsion systems was designed based on ISO 7235. The substitution test for determining both the insertion loss and pressure drop of mufflers was carried out. A ship exhaust muffler is considered as a test example and the insertion loss and pressure drop are obtained.

  • PDF

Reliability Evaluation of Torque Generator (토크 발생기의 신뢰성 향상)

  • Jung, D.S.;Lee, Y.B.;Park, J.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.59-65
    • /
    • 2012
  • Torque Generator is a product which has function to transform hydraulic energy to mechanical energy of torque and rotating speed, and be used for direction change device of agricultural machines. This study proposes failure analysis and test analysis on torque generator and introduces a process that reliability of a product is enhanced by design improvement. And also it presents improvements of maximum output torque by modifying design and surface treatment. Lastly it verifies reliability improvement by analyzing test results of before and after life test.

The Mechanical Properties of Working Clothes Materials Considering Industrial Settings (산업현장을 고려한 작업복 소재의 역학적 특성 연구)

  • Bae, Hyun Sook
    • Textile Coloration and Finishing
    • /
    • v.25 no.2
    • /
    • pp.140-151
    • /
    • 2013
  • In order to investigate the mechanical properties of working clothes materials considering industrial settings, the test weaving materials were compared with the existing materials depending on the season. The material design of the test fabrics were changed through fineness, composition, density of materials then subsequently treated with functional finish. As a result of evaluation of the forms according to KES-FB system, Koshi was deduced, and Numeri and Fukurami were increased. Thereby, the test weaving materials became flexible, surface became smoother, elasticity and volume characteristics indicated to have been improved. Consequently, the THV value of working clothes materials for test weaving was increased compared to existing materials which indicated improved result of the total hand value. Specially, the winter cloth material indicated improved drape characteristics and dimensional characteristics, showed improved liveliness as being compressed softly.

Evaluation of Load Rejection to House Load Test at 100% Power for YGN 4

  • Sohn, Jong-Joo;Jeong, Won-Sang;Chi, Sung-Goo;Seo, Jong-Tae;Kim, Si-Hwan
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.588-595
    • /
    • 1995
  • The Load Rejection to House Load test at 100% power was successfully performed during the YGN 4 PAT period. In this test, all plant control systems automatically controlled the plant from 100% power to house load operation mode. The LTC code, which was used in the performance analysis during the design process of YGN 3&4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design.

  • PDF