• 제목/요약/키워드: Design Space Reduction Method

검색결과 147건 처리시간 0.034초

에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계 (The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner)

  • 심현진;이성진;강태호;이정윤;오재응
    • 대한기계학회논문집A
    • /
    • 제30권2호
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.

건물과 수목의 그림자에 의한 도시의 열 분포 산정 및 저감효과 연구 (Estimating the urban radiation heat flux distribution and the reduction effect of building and tree shade)

  • 박채연;이동근;윤준하
    • 한국환경복원기술학회지
    • /
    • 제21권6호
    • /
    • pp.1-13
    • /
    • 2018
  • Mapping radiation heat flux of urban area is essential for urban design and landscape planning. Because controlling urban geometry and generating green space are important urban design strategies for reducing urban heat, urban planner and designer need to recognize the micro urban heat distribution for adequate urban planning. This study suggests a new methodology for mapping urban radiation heat flux in a micro scale considering buildings and trees' shade. For doing that, firstly, we calculate net radiation for each urban surfaces (building, road (not shaded, building shaded, tree shaded), ground (not shaded, building shaded, tree shaded), tree (not shaded, building shaded)). Then, by multiplying the area ratio of surfaces to the net radiation, we can obtain the radiation heat flux in micro-scale. The estimated net radiation results were found to be robust with a $R^2$ of 90%, which indicates a strong explanatory power of the model. The radiation heat flux map for 12h $17^{th}$ August explains that areas under the building and tree have lower net radiation heat flux, indicating that shading is a good strategy for reducing incident radiation. This method can be used for developing thermal friendly urban plan.

일체형 강관 파이프루프 시공에 따른 주변 지반의 토압 분포 특성 분석 (Analysis on the characteristics of the earth pressure distribution induced by the integrated steel pipe-roof construction)

  • 심영종;진규남;송기일
    • 한국터널지하공간학회 논문집
    • /
    • 제15권5호
    • /
    • pp.455-468
    • /
    • 2013
  • 최근 비개착공법으로 지하차도 시공 시 강관을 지반에 압입한 후 강관자체를 철근과 모르타르로 보강하는 다양한 일체형 파이프루프 공법이 적용되고 있다. 이러한 일체형 파이프루프 공법은 상재하중에 대해 지보강성 효과를 발휘하여 콘크리트 지하차도 구조물에 작용하는 응력을 한층 감소시킬 것으로 예상된다. 또한 아칭효과에 의해 주변지반의 연직방향 및 수평방향의 토압이 변화하게 된다. 본 연구에서는 일체형 파이프루프 시공에 따른 주변지반의 토압 분포 특성을 분석하고, 일체형 파이프루프 내측에 시공되는 콘크리트에 작용하는 토압을 분석하기 위하여 유한차분 수치해석을 통해 파이프루프의 체결 특성을 모델링하고 응력 및 변위거동을 분석하였다. 지반과 구조물의 경계에 인터페이스 요소를 도입하여 지반구조물의 상호작용을 분석하였다. 분석 결과, 본체 콘크리트 구조물에 작용하는 연직토압은 파이프루프의 강성과 아칭 작용에 의해 원상태의 연직토압보다 큰 폭으로 감소하여 작용하는 것을 확인하였다. 지하차도 구조물의 단면 설계 시 설계하중에 대해 이러한 아칭작용에 의한 연직토압의 감소를 고려한다면 경제성을 보다 확보할 수 있을 것으로 판단된다.

지표유출수 분석을 통한 상습침수유역의 분산식 우수관리통로 설계 (Designing a Decentralized Stormwater Management Corridor for a Flood-Prone Watershed using Surface Runoff Analysis)

  • 이슬;이유미
    • 한국조경학회지
    • /
    • 제43권3호
    • /
    • pp.13-26
    • /
    • 2015
  • 우리나라의 상당수의 도시지역에서 급격한 도시화로 인한 불투수면의 증가와 노후화된 하수관망으로 집중강우 시 상습적인 침수피해가 반복되고 있다. 그러나 하류지역의 하수관 크기를 확장하거나, 펌프장을 추가하는 등 배수계통의 수용량을 늘리는 기존의 중앙집중식 우수관리체계는 유역 전반에 걸쳐 일어난 도시화와 기후변화로 인한 강수량의 증가로 인한 지표유출수 문제를 근본적으로 개선하지 못하고 있다. 따라서 도시홍수 요인에 대응하는 지속가능한 우수관리방식으로 기존의 배수체계를 유지하면서 지표유출수를 최소화하고 지표면의 저류효과를 극대화하는 분산식 우수관리체계의 필요성이 요구된다. 본 연구에서는 최근 침수피해가 가중되고 있는 상습침수지역에 분산식 우수관리체계를 적용하는 것을 목적으로, 대상지의 조건에 적합한 다양한 우수유출저감기법을 활용하여 상류 중류 하류에 걸쳐 조성되는 우수관리통로(Stormwater Managemnt Corridor)를 제안하였다. 연구방법으로는 수정합리식(Modified Rational Method)을 이용하여 대상지 유역 전반의 지표유출수의 발생패턴을 정량적으로 도출하였고, 연구대상지인 동두천시의 중앙동 및 생연동 지역의 지형 및 토지피복, 토양의 자연적 특성과 수계를 분석하여 유역별 특성에 따라 6가지 유형의 설계전략을 적용하였다. 연구결과는 배치도와 단면도, 상세설계도로 제시하였고, 설계안을 통해 저류가 가능한 지표유출수량을 도출함으로써 설계의 예상효과를 검증하였다. 본 연구를 통해 주로 토목적인 측면에서 계획되어왔던 우수관리체계를 조경적 관점에서 계획, 설계, 검증함으로써 도시의 그린 인프라스트럭쳐로서의 오픈스페이스의 기능적 가치를 제고하고, 상습침수지역의 지속가능한 계획과 관리에 기여하고자 한다.

전원 잡음을 줄이기 위한 평면계획 단계에서의 Decoupling Capacitance 할당 (Decoupling Capacitance Allocation at the Floorplan Level for Power Supply Noise Reduction)

  • 허창룡;임종석
    • 대한전자공학회논문지SD
    • /
    • 제42권9호
    • /
    • pp.61-72
    • /
    • 2005
  • 본 논문에서는 평면계획 단계에서 모듈의 전원 잡음을 줄이기 위해 필요한 decoupling capacitance를 효과적으로 할당하는 방법을 제시한다. 먼저, 각 모듈의 decoupling capacitance가 과대평가되고 추가 면적 삽입으로 모듈의 전원 잡음이 변하는 기존 접근 방법의 문제점을 살펴보고, 이를 해결할 수 있는 새로운 방법을 제시한다. 또한, 선형프로그래밍 방법보다 빠른 시간 내에 decoupling capacitance 면적을 위한 빈 공간을 할당하는 간단한 휴리스틱 방법을 제안한다. 실험결과에서 제시된 방법은 Zhao[4]의 방법과 비교하여 decoupling capacitance 면적이 평균 $7.9\%$ 감소하고, 이로 인해 평면계획 결과의 전체 면적과 와이어 길이가 감소하였다. 또한, 추가 면적 삽입으로 인한 모듈의 전원 잡음 문제를 잘 해결하고 있음을 확인하였다. 수행시간 비교에서는 평균 $11.6\%$의 향상을 보였다.

A constrained minimization-based scheme against susceptibility of drift angle identification to parameters estimation error from measurements of one floor

  • Kangqian Xu;Akira Mita;Dawei Li;Songtao Xue;Xianzhi Li
    • Smart Structures and Systems
    • /
    • 제33권2호
    • /
    • pp.119-131
    • /
    • 2024
  • Drift angle is a significant index for diagnosing post-event structures. A common way to estimate this drift response is by using modal parameters identified under natural excitations. Although the modal parameters of shear structures cannot be identified accurately in the real environment, the identification error has little impact on the estimation when measurements from several floors are used. However, the estimation accuracy falls dramatically when there is only one accelerometer. This paper describes the susceptibility of single sensor identification to modelling error and simulations that preliminarily verified this characteristic. To make a robust evaluation from measurements of one floor of shear structures based on imprecisely identified parameters, a novel scheme is devised to approximately correct the mode shapes with respect to fictitious frequencies generated with a genetic algorithm; in particular, the scheme uses constrained minimization to take both the mathematical aspect and the realistic aspect of the mode shapes into account. The algorithm was validated by using a full-scale shear building. The differences between single-sensor and multiple-sensor estimations were analyzed. It was found that, as the number of accelerometers decreases, the error rises due to insufficient data and becomes very high when there is only one sensor. Moreover, when measurements for only one floor are available, the proposed method yields more precise and appropriate mode shapes, leading to a better estimation on the drift angle of the lower floors compared with a method designed for multiple sensors. As well, it is shown that the reduction in space complexity is offset by increasing the computation complexity.

동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구 (Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter)

  • 류리;서장후;김용성
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

프리텐션 쏘일네일링 시스템의 안정해석 및 설계 (Stability Analysis and Design of the Pretension Soil Nailing System)

  • 박시삼;김홍택;최영근
    • 한국지반공학회논문집
    • /
    • 제20권7호
    • /
    • pp.197-206
    • /
    • 2004
  • 쏘일네일링 공법을 도심지 지하굴착 공사에 있어, 지중매설물이 인접하여 존재하거나 대지경계선 등의 준수 등 시공조건에 따라서 설치네일의 길이가 제한되는 경우 및 연약한 지반을 보강할 경우 등과 같은 벽체변위 및 지표침하 억제와 안정성 증대 등을 위하여, 지반앵커공법과 유사한 프리텐션 방식의 도입이 필요한 실정이다. 지반앵커공법과 유사한 프리텐션 방식의 쏘일네일링 공법을 도입하게 될 경우, 단계별 굴착시 발생하는 변위를 최소화할 수 있을 것으로 예상되며 국부적인 안정성도 증대할 것으로 사료된다. 따라서, 본 연구에서는 단계별 굴착시 유발되는 벽체변위 및 침하량 등을 억제하기 위한 노력의 일환으로, 프리텐션 쏘일네일링 시스템을 개발하였다. 또한 최대 프리텐션하중 및 프리텐션 시스템의 안정성을 평가하기 위해, 영향원 반경, 다이레이턴시 각, 정착길이 등을 반영한 설계기법을 제안하였으며, 펀칭전단파괴에 저항할 수 있는 숏크리트의 요구두께를 결정하는 신뢰도 평가기법을 제안하였다. 아울러 설계예제와 $FLAC^{2D}$ 프로그램 수치해석을 통해 프리텐션에 의한 변위 감소효과를 살펴봤으며, 전단강도감소기법을 도입한 안정해석이 $FLAC^{2D}$ 프로그램을 토대로 수행되었다.

SEM파일의 이완하중 산정방법별 이완하중량 비교 연구 (A study on the comparison by the methods of estimating the relaxation load of SEM-pile)

  • 김형규;박은형;조국환
    • 한국터널지하공간학회 논문집
    • /
    • 제20권3호
    • /
    • pp.543-560
    • /
    • 2018
  • 도심지 지하공간의 개발과 운행선 하부를 저토피로 입체 교차화하는 시설 증가에 따라 비개착식 공법의 수요는 점차 증가추세에 있으나 대다수의 공법은 중대구경 강관을 압입하여 루프를 형성하고 내부를 굴착하는 파이프루프(Pipe roof) 계열의 공법이 주로 적용되고 있다. 강관 압입 시 발생되는 이완영역 및 하중은 여러 인자의 영향을 받게 되나 가장 큰 요소는 압입하는 강관의 크기에 좌우되며 이는 강관 루프 내 지중구조물에 작용하는 하중의 크기로 볼 수 있다. 지반의 교란 및 이완하중 발생을 최소화시키기 위해 개발된 SEM공법(Super Equilibrium Method)은 기존의 중대구경 강관 대신 ${\Phi}114mm$ 내외의 소구경 강관을 사용한다. 이 소구경 강관을 SEM파일로 명명하였으며 강관의 선 압입 및 그라우팅 보강을 실시한 후 지반의 침하나 융기 없이 지반 내 횡단구조물을 유압잭을 이용하여 압입하게 된다. 이와 같이 SEM공법의 구성 중 지보역할을 하는 SEM파일은 선단부 굴착 시 지반의 붕락을 방지하고 상재하중을 지지하기 위한 길이 5 m 내외의 Fore poling 파일이며 이 파일의 배치간격, 시공연장, 부재의 강성 등을 산정하기 위해서는 이완영역의 적절한 산정이 필수적이다. 본 논문은 SEM공법의 최적설계를 위하여 SEM파일 압입 시 발생되는 이완하중 산정 값을 비교분석하였다. 이완영역 산정에 근거한 주요 이론식 및 경험식들의 영향인자를 고려하여 분석하고 FEM analysis (유한요소 해석)를 수행하여 SEM파일에 적합한 이완하중 산정을 검토하였다. 또한 실제 SEM파일 압입 및 굴착 시 발생되는 지반이완을 확인하기 위해 강관압입 축소모형실험을 수행하였으며 토피고/강관(H/D)에 따른 지표침하 및 지반이완을 정량적으로 검토하였다.

MMH-NTO 이원추진제 추력기의 배기가스 거동 해석 연구 (Exhaust Plume Behavior Study of MMH-NTO Bipropellant Thruster)

  • 김현아;이균호
    • 한국항공우주학회지
    • /
    • 제45권4호
    • /
    • pp.300-309
    • /
    • 2017
  • 우주비행체는 우주공간에서 소형 추력기를 통해 연소가스를 노즐 외부로 배출시킴으로써 궤도보정 및 자세제어에 필요한 반작용 모멘텀을 발생시킨다. 이때 배출된 배기가스가 우주비행체의 표면과 충돌하면서 발생된 교란 힘 및 교란토크, 열 부하, 표면 오염 등은 우주비행체의 수명 단축 및 기능저하를 유발시킬 수 있으므로 추력기 배기가스 거동에 관한 예측은 우주비행체 설계시 매우 중요한 절차라고 할 수 있다. 본 연구에서는 우주비행체의 자세제어용 추력기로 사용되는 10 N급 이원추진제 추력기의 배기가스 거동을 수치적으로 해석함으로써 우주비행체 설계에 필요한 핵심기술을 확보하는 것이 목적이다. 이를 위해 모노메틸하이드라진(MMH) 연료와 사산화이질소(NTO) 산화제의 화학평형반응과 추력기 노즐 내부 연속체 영역 계산을 수행한 후 배기가스 해석을 위한 직접모사법(DSMC)의 유입조건으로 적용하였다. 해석 결과, 이원추진제 추력기 노즐 부근에서 배기가스의 화학종 박리와 같은 비평형 팽창과 후방유동의 특성들을 예측할 수 있었다.