• 제목/요약/키워드: Design Slip Strength

검색결과 129건 처리시간 0.027초

반복재하 실험에 의한 고력볼트 철골 보 이음부의 내진거동 연구 (Cyclic Seismic Performance of High-Strength Bolted-Steel Beam Splice)

  • 이철호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.57-64
    • /
    • 1998
  • This paper presents the cyclic seismic performance of slip-critically designed, high-strength bolted-beam splice in steel moment frame. Before the moment connection reaching its plastic strength, unexpected premature slippage occurred at the slip-critically designed beam splice during the test. The experimentally observed frictional coefficients were as low as about 50% to 60% of nominal (code) value. Nevertheless, the bearing type behavior mobilized after the slippage transferred the increasing cyclic loads successfully, i.e., the consequence of slippage into bearing was not catastrophic to the connection behavior. The test result seems to indicate that the traditional beam splice design basing upon (bolt-hole deducted) effective flange area criterion may not be sufficient in developing the plastic strength of moment connections under severe earthquake loading. New procedure for achieving slip-critical beam splice design is proposed based on capacity design concept.

  • PDF

A study on behavior of steel joints that combine high-strength bolts and fillet welds

  • Chang, Heui-Yung;Yeh, Ching-Yu
    • Steel and Composite Structures
    • /
    • 제31권4호
    • /
    • pp.361-372
    • /
    • 2019
  • In recent years, considerable attention has been paid to the research and development of high-strength steel plates, with particular emphasis on the enhancement of the seismic resistance of buildings and bridges. Many efforts have also been undertaken to improve the properties of high-strength bolts and weld materials. However, there are still different opinions on steel joints that combine high-strength bolts and fillet welds. Therefore, it is necessary to verify the design specifications and guidelines, especially for newly developed 1,400-MPa high-strength bolts, 570-MPa steel plates, and weld materials. This paper presents the results of literature reviews and experimental investigations. Test parameters include bolt strengths, weld orientations, and their combinations. The results show that advances in steel materials have increased the plastic deformation capacities of steel welds. That allows combination joints to gain their maximum strength before the welds have fracture failures. When in combination with longitudinal welds, high-strength bolts slip, come in contact with cover plates, and develop greater bearing strength before the joints reach their maximum strength. However, in the case of combinations with transverse welds, changes in crack angles cause the welds to provide additional strength. The combination joints can therefore develop strength greater than estimated by adding the strength of bolted joints in proportion to those of welded joints. Consequently, using the slip resistance as the available strength of high-strength bolts is recommended. That ensures a margin of safety in the strength design of combination joints.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.

Bond-slip behaviour of H-shaped steel embedded in UHPFRC

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Chen, Chufa;Li, Yongjie;Lin, Zhiwei;Liao, Wen-I
    • Steel and Composite Structures
    • /
    • 제38권5호
    • /
    • pp.563-582
    • /
    • 2021
  • The present study experimentally and analytically investigated the push-out behaviour of H-shaped steel section embedded in ultrahigh-performance fibre-reinforced concrete (UHPFRC). The effect of significant parameters such as the concrete types, fibre content, embedded steel length, transverse reinforcement ratio and concrete cover on the bond stress, development of bond stress along the embedded length and failure mechanism has been reported. The test results show that the bond slip behaviour of steel-UHPFRC is different from the bond slip behaviour of steel-normal concrete and steel-high strength concrete. The bond-slip curves of steel-normal concrete and steel-high strength concrete exhibit brittle behaviour, and the bond strength decreases rapidly after reaching the peak load, with a residual bond strength of approximately one-half of the peak bond strength. The bond-slip curves of steel-UHPFRC show an obvious ductility, which exhibits a unique displacement pseudoplastic effect. The residual bond strength can still reach from 80% to 90% of the peak bond strength. Compared to steel-normal concrete, the transverse confinement of stirrups has a limited effect on the bond strength in the steel-UHPFRC substrate, but a higher stirrup ratio can improve cracking resistance. The experimental campaign quantifies the local bond stress development and finds that the strain distribution in steel follows an exponential rule along the steel embedded length. Based on the theory of mean bond and local bond stress, the present study proposes empirical approaches to predict the ultimate and residual bond resistance with satisfactory precision. The research findings serve to explain the interface bond mechanism between UHPFRC and steel, which is significant for the design of steel-UHPFRC composite structures and verify the feasibility of eliminating longitudinal rebars and stirrups by using UHPFRC in composite columns.

Strut-tie model evaluation of behavior and strength of pre-tensioned concrete deep beams

  • Yun, Young Mook
    • Computers and Concrete
    • /
    • 제2권4호
    • /
    • pp.267-291
    • /
    • 2005
  • To date, many studies have been conducted for the analysis and design of reinforced concrete members with disturbed regions. However, prestressed concrete deep beams have not been the subject of many investigations. This paper presents an evaluation of the behavior and strength of three pre-tensioned concrete deep beams failed by shear and bond slip of prestressing strands using a nonlinear strut-tie model approach. In this approach, effective prestressing forces represented by equivalent external loads are gradually introduced along strand's transfer length in the nearest strut-tie model joints, the friction at the interface of main diagonal shear cracks is modeled by the aggregate interlock struts along the direction of the cracks in strut-tie model, and an algorithm considering the effect of bond slip of prestressing strands in the strut-tie model analysis and design of pre-tensioned concrete members is implemented. Through the strut-tie model analysis of pre-tensioned concrete deep beams, the nonlinear strut-tie model approach proved to present effective solutions for predicting the essential aspects of the behavior and strength of pre-tensioned concrete deep beams. The nonlinear strut-tie model approach is capable of predicting the strength and failure modes of pre-tensioned concrete deep beams including the anchorage failure of prestressing strands and, accordingly, can be employed in the practical and precise design of pre-tensioned concrete deep beams.

과대 볼트구멍에 따른 고장력볼트 마찰이음의 사용성에 관한 연구 (A Study on the Serviceability of High-Tension Bolt Friction Joints according to Oversize Bolt Holes)

  • 박정웅;양승현;조강균
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2055-2061
    • /
    • 2009
  • 고장력볼트 마찰이음에서 모재 및 덮개판을 과대공 제작하였을 경우 연결부의 내하력에 다소의 변화가 발생 될 수 있다. 본 논문에서는 고장력볼트 마찰이음에서 표준공과 과대공에 따라 미끄럼하중과 미끄럼계수의 변화를 파악하기 위하여 정적인장시험을 실시하였다. 정적인장시험결과 모재 및 덮개판의 과대공 제작에 따라 미끄럼계수의 변화가 다소 발생하였으나 이를 정형화시키기에는 다소 무리가 따랐으며, 미끄럼강도는 표준공 제작시의 값과 과대공제작시의 값이 최대 26%의 차이를 나타내었다. 그러나 이는 설계미끄럼강도를 초과하기 때문에 사용하중하에서 연결부의 사용성에 미치는 영향이 미약하므로 강부재 제작시 부득이하게 발생할 수 있는 과대공에 따른 규정을 보다 유연하게 적용시킨다면 구조물의 설계 및 시공시 효율성과 경제성 증대의 효과가 기대된다고 판단되었다.

Static behavior of high strength friction-grip bolt shear connectors in composite beams

  • Xing, Ying;Liu, Yanbin;Shi, Caijun;Wang, Zhipeng;Guo, Qi;Jiao, Jinfeng
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.407-426
    • /
    • 2022
  • Superior to traditional welded studs, high strength friction-grip bolted shear connectors facilitate the assembling and demounting of the composite members, which maximizes the potential for efficiency in the construction and retrofitting of new and old structures respectively. Hence, it is necessary to investigate the structural properties of high strength friction-grip bolts used in steel concrete composite beams. By means of push-out tests, an experimental study was conducted on post-installed high strength friction-grip bolts, considering the effects of different bolt size, concrete strength, bolt tensile strength and bolt pretension. The test results showed that bolt shear fracture was the dominant failure mode of all specimens. Based on the load-slip curves, uplifting curves and bolt tensile force curves between the precast concrete slab and steel beam obtained by push-out tests, the anti-slip performance of steel-concrete interface and shear behavior of bolt shank were studied, including the quantitative analysis of anti-slip load, and anti-slip stiffness, frictional coefficient, shear stiffness of bolt shank and ultimate shear capacity. Meanwhile, the interfacial anti-slip stiffness and shear stiffness of bolt shank were defined reasonably. In addition, a total of 56 push-out finite element models verified by the experimental results were also developed, and used to conduct parametric analyses for investigating the shear behavior of high-strength bolted shear connectors in steel-concrete composite beams. Finally, on ground of the test results and finite element simulation analysis, a new design formula for predicting shear capacity was proposed by nonlinear fitting, considering the bolt diameter, concrete strength and bolt tensile strength. Comparison of the calculated value from proposed formula and test results given in the relevant references indicated that the proposed formulas can give a reasonable prediction.

대형선 프로펠러보스 슬립 손상부에 대한 응력 계산에 관한 연구 (The Study for Stress Calculation of Slip Damage between Propeller Boss and Shaft on the Large Vessel)

  • 백신영
    • 해양환경안전학회지
    • /
    • 제17권3호
    • /
    • pp.291-294
    • /
    • 2011
  • 프로펠러와 프로펠러축이 슬립(Slip)되는 사고가 발생하면 추진력 상실로 인한 안전과 경제적면에서 막대한 문제가 할 수 있다. 본 연구에서는 대형선박에서 슬립사고(Slip damage) 발생 원인을 사고 선박 승선원 면담, 신조선의 도면검토, 보험사 조사관 사고 보고서 등을 통해 조사하였다. 추가로 프로펠러의 재질에 대한 충격강도를 확인하기 위하여 압축시험을 실시하였다. 본 연구 결과는 키가 없는(Keyless type) 프로펠러의 접촉강도 설계 기준에 적용 할 수 있고, 나아가 프로펠러보스와 축이 슬립하는 사고를 방지하는데 유용한 자료를 제공 할 것으로 판단된다.

부재 및 고장력볼트 구멍치수에 따른 미끄러짐계수의 실험적 연구 (Experimental Study on the Slip Coefficient with Member Type and Dimensions of High Tension Bolt Hole)

  • 양승현
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.4277-4283
    • /
    • 2012
  • 고장력볼트 마찰이음에서 접촉면의 표면상태에 따라 다양한 값을 갖는 미끄러짐계수는 볼트의 축력과 미끄러짐하중에 의해 결정되어진다. 또한 접촉면적은 미끄러짐하중에 영향을 미치게 되므로 볼트구멍에 따라 변하는 접촉면적은 미끄러짐계수와 상관관계를 갖게 된다. 본 연구에서는 부재의 종류, 볼트의 직경 및 볼트구멍의 크기에 따른 미끄러짐계수와 미끄러짐하중의 변화를 파악하기 위하여 32개의 시험편을 제작하여 휨시험 및 인장시험을 실시하였다. 과대볼트구멍으로 제작된 시험편의 미끄러짐하중은 표준볼트구멍으로 제작된 미끄러짐하중의 80%이상의 강도를 발휘하였으며 설계 미끄러짐강도를 상회하였다. 또한 과대볼트구멍으로 제작된 시험편과 표준볼트구멍으로 제작된 시험편의 순단면적비와 미끄러짐비간에는 상당한 상관성을 가지는 것으로 나타났다. 그러나 시험결과가 각 시험체에 따라 다소의 차이를 보이는 것은 미끄러짐계수의 중요한 파라메타인 고장력볼트의 도입축력이 감소하기 때문인 것으로 판단된다. 볼트구멍 크기의 증가는 미끄러짐 계수 뿐 아니라 볼트 축력의 감소를 야기시키므로 설계강도의 감소를 초래하는 것은 자명한 사실이지만 외국의 경우와 같이 구조적 안정을 위협하지 않는 범위 내에서 볼트구멍에 대한 규정에 유연성을 갖는 것도 시공성과 효율성에 긍정적인 요소가 될 것으로 기대된다.

피라미드형 전단연결재의 전단거동 (Shear Behavior of Pyramidal Shear Connectors)

  • 이경동;한상호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.131-137
    • /
    • 2000
  • In order to evaluate the design shear strength of composite slabs with truss-shaped shear connectors(TSC), a series of push-out tests on several types of specimens was carried out. The test results for the two parameters of bearing area and solid angle of the connector were compared to obtain the design shear force of the truss-shaped connectors. The results obtained from this study are as follows: (1) The slip-coefficients of TSC ranges from 0.87 to 3.12(${\times}10^6kgf/cm$). (2) The slip stiffness and the shear strength of TSC with $60.6cm^2$ bearing area are greater than those with $14.6cm^2$. (3) For estimating the allowable shear force of TSC, a design equation that is based on the bearing strength of the connector is suggested. (4) The mean safety factors of the critical force and the ultimate force are 2.38 and 4.62. respectively.

  • PDF