• 제목/요약/키워드: Design Morphology

검색결과 283건 처리시간 0.029초

항암치료 중인 환자에서 파절된 금속-도재관을 CAD/CAM으로 제작된 complete contour zirconia surveyed crown(완전한 윤곽을 가진 지르코니아 써베이드 전장관) 보철 수복: 증례 보고 (An alternative method to convert fractured metal ceramic surveyed crown into a complete contour zirconia surveyed crown using CAD-CAM technology under anticancer treatments: a clinical report)

  • 이선기;양홍서;박상원;윤귀덕;임현필
    • 구강회복응용과학지
    • /
    • 제31권1호
    • /
    • pp.45-49
    • /
    • 2015
  • 본 증례는 기존의 국소의치에서 파절된 metal-ceramic surveyed crown을 complete contour zirconia surveyed crown으로 전환하는 간단하고 편리한 CAD/CAM 기술을 보고하고 있다. 항암치료를 받고 있는 환자의 기존 metal-ceramic surveyed crown 외형, 형태학적 특성, 레스트 시트를 complete contour zirconia surveyed crown으로 제작하는 복제 기법에 대해 보고한다.

Pre-deposition of iron-based adsorbents on the removal of humic acid using ultrafiltration and membrane fouling

  • Tian, Hailong;Sun, Lihua;Duan, Xi;Chen, Xueru;Yu, Tianmin;Feng, Cuimin
    • Membrane and Water Treatment
    • /
    • 제9권6호
    • /
    • pp.473-480
    • /
    • 2018
  • The effect of three iron-based adsorbents pre-depositing on ultrafiltration membrane for humic acid (HA) removal and membrane fouling was investigated. The result showed that pre-depositing adsorbents on membrane could not only reduce membrane fouling but also enhance HA removal. The flux was related to the adsorbent dosage and the optimal dosage for pre-deposition was $35.0g/m^2$. The dissolved organic carbon (DOC) removal of HA was 38.3%, 67.3% and 41.1% respectively when pre-deposited $35.0g/m^2$ $FeO_xH_y$, $MnFe_2O_4$ and $Fe_3O_4$ on membrane. Different adsorption effect of adsorbents on HA contributed to increasing of the flux at different level. Zeta potential of three adsorbents all decreased after adsorbed HA. The adsorption capacity of the three adsorbents was $FeO_xH_y$ > $MnFe_2O_4$ > $Fe_3O_4$. Atomic Force Microscopy (AFM) measurement showed the thickness of pre-deposition layers formed by different adsorbents was different. The scanning electron microscope (SEM) detection showed the morphology and compactness of pre-deposition layers formed by different adsorbents was different.

고체형 염료감응 태양전지용 초분자 전해질 개발 (Design of Supramolecular Electrolytes for Solid State Dye-sensitized Solar Cells)

  • 고종관;고주환;서진아;김종학
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2009
  • Solid-state dye-sensitized solar cells (DSSCs) have been constructed employing supramolecular electrolytes with multiple hydrogen bonding. A supramolecule was facilely synthesized by one-pot reaction between the amines of methyl isocytosine (MIC) and the epoxy groups of poly(ethylene glycol diglycidyl ether) (PEGDGE) to produce quadruple hydrogen bonding units. Hydrogen bonding interactions and dissolution behavior of salt in supramolecular electrolytes are investigated. The ionic conductivity of the supramolecular electrolytes with ionic liquid, i.e. 1-methyl-3-propylimidazolium iodide (MPII) reaches $8.5{\times}10^{-5}$ S/cm at room temperature, which is higher than that with metal salt (KI). A worm-like morphology is observed in the FE-SEM micrographs of $TiO_2$ nanoporous layer, due to the connection of $TiO_2$ nanoparticles resulting from adequate coating by electrolytes. DSSCs employing the supramolecular electrolytes with MPII and KI exhibit an energy conversion efficiency of 2.5 % and 0.5 %, respectively, at 100 $mW/cm^2$, indicating the importance of the cation of salt. Solar cell performances were further improved up to 3.7 % upon introduction of poly(ethylene glycol dimethyl ether) (PEGDME) with 500 g/mol.

  • PDF

Synthesis and Characterization of An Omnidirectional ZnO Piezoelectric Nanogenerator

  • Lee, Jun Young;Yeo, Jong Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.622-622
    • /
    • 2013
  • Piezoelectric energy harvesting (PEH) device refers to a power device for acquiring mechanical energy from the environment surrounding us which would otherwise be wasted and for converting it into usable electrical energy. While much work has been done on developing ZnO nanogenerator (NG) with nanowire arrays, there are some issues of not only scaling up its output power but also optimizing structure for operating feasibly in various conditions. Efficiency of NG is highly dependent on fixed orientation. But in many cases, it is not easy to predict where the pressure and vibration may come from. Furthermore, the direction of the applied mechanical stress is usually non-stationary and can be random in various practical applications. Therefore an omnidirectional PEH is needed.In this work, we investigate an omnidirectional PEH device consisting ZnO nanowires. We deposited spiral patterned ZnO seed layer on Kapton film. We deposited thin Cr layer on the ZnO seed layer using DC-sputter to form a passivation layer to retard un-expected growth of ZnO nanowires. We grew ZnO nanowires along the spiral arms using hydrothermal method. ZnO nanowires have been selectively grown from the ZnO sidewall without Cr layer and have the average length of$5{\mu}m$ and the average diameter of 40nm. We reduced the defect in the as-grown ZnO nanowires by O2 plasma using asher and by thermal treatment using RTA. Consequently, each nanowire has different directions to each other. This isotropic design can lead to the omnidirectional power generation. The morphology of NG is characterized with FESEM. Maximum output power of the device is measured by using a picoammeter and a nanovoltmeter.

  • PDF

Analysis of landing mission phases for robotic exploration on phobos mar's moon

  • Stio, A.;Spinolo, P.;Carrera, E.;Augello, R.
    • Advances in aircraft and spacecraft science
    • /
    • 제4권5호
    • /
    • pp.529-541
    • /
    • 2017
  • Landing phase is one of the crucial and most important phases during robotic aerospace explorations. It concerns the impact of the landing module of a spacecraft on a celestial body. Risks and uncertainties of landing are mainly due to the morphology of the surface, the possible presence of rocks and other obstacles or subsidence. The present work quotes results of a computational analysis direct to investigate the stability during the landing phase of a lander on Phobos, a Mars Moon. The present study makes use of available software tools for the simulation analyses and results processing. Due to the nature of the system under consideration (i.e., large displacements and interaction between several systems), multibody simulations were performed to analyze the lander's behavior after the impact with the celestial body. The landing scenario was chosen as a result of a DOE (Design of Experiments) analysis in terms of lander velocity and position, or ground slope. In order to verify the reliability of the present multibody methodology for this particular aerospace issue, two different software tools were employed in order to emphasize two different ways to simulate the crash-box, a particular component of the system used to cushion the impact. The results show the most important frames of the simulations so as to provide a general idea about how lander behaves in its descent and some trends of the main characteristics of the system. In conclusion, the success of the approach is demonstrated by highlighting that the results (crash-box shortening trend and lander's kinetic energy) are comparable between the two tools and that the stability is ensured.

Four years Incidence Rate of Colorectal Cancer in Iran: A Survey of National Cancer Registry Data - Implications for Screening

  • Azadeh, Safaee;Reza, Fatemi Seyed;Sara, Ashtari;Mohsen, Vahedi;Bijan, Moghimi-Dehkordi;Zali, Zali Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2695-2698
    • /
    • 2012
  • Introduction: Design and implementation of screening programs in each country must be based on epidemiological data. Despite the relatively high incidence of CRC, there is no nationwide comprehensive program for screening in Iran. This study was designed to investigate national CRC data and help to determine guidelines for screening. Methods: Incidence data used in this study were obtained from Iranian annual of National Cancer Registration report. Age standardized rates (ASR)were calculated using world standard population and were categorized by age, sex, anatomic subsite and morphology of tumor. Data were analyzed using SPSS.V.13 and Open Source Epidemiologic Statistics for Public Health software (OpenEpi v.2.3.1). Results: A quarter of cases were less than 50 years of age. The majority of tumors were detected in the colon. The overall ASR in the four years period was 38.0 per 100000 and was higher for men compared women (P<0.05). Incidence rate of colorectal cancer increased with age. Conclusion: Results of present study indicated that incidence of colorectal cancer is relatively high in Iran. Incidence of CRC in people under 50 years and in rectum were reported higher than other countries that related etiologic factors should be investigate in further studies. According to the increasing of ASR after age 50 years, it seems that onset of screening at age 50 would be appropriate.

피부각질의 유지질상태에서 조절기능구조에 관한 연구 (A study of control capacity structure of by the lipoid state of stratum on the skin)

  • 김정래;김혜주
    • 문화기술의 융합
    • /
    • 제3권3호
    • /
    • pp.37-42
    • /
    • 2017
  • 본 연구는 피부의 각질층에 분포되어 있는 유지질의 변화 상태를 조절하는 구조체계에 대해 고안한다. 피부구조에 유지질 성분이 어떻게 진행되는지 형태학으로 구성하였고, 주어진 세포사이와 세포횡단의 조건으로 기계적으로 조절되는 형태를 구성하였으며, 구조적인 기능으로 조절기능의 변화 상태를 확인하였다. 유지질 성분에서 피부의 모형을 구성하여 각층에 따른 유기질 상태의 피부 임피던스를 피부의 측정 임피던스 시스템으로 구성하여 진행하였다. 측정 임피던스는 ${\lambda}-Lip-RSC$, ${\lambda}-Lip-RSL$, ${\lambda}-Lip-CSG$, ${\lambda}-Lip-CSS$${\lambda}-Lip-RSB$로 형성하였고, 세포사이와 세포횡단의 조건으로 변화의 차가 있고, 변환을 제어하는 전달시스템을 구성과 변환모델을 세분화하여 구축하였다. 앞으로 유지질 상태에서 피부의 기능적 효능조절이 가능한 유지질 성분의 조절시스템을 구성하여 지속적인 피부의 개선효과가 진행 될 것으로 예상된다.

비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례 (Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report)

  • 고창우;김민지;양홍서;박상원;박찬;윤귀덕
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.166-172
    • /
    • 2018
  • 상악 전치부 치료 시에는 다양한 구도 속에서 체계적인 진단을 통해 적절한 형태와 배열, 색조를 가지는 수복물을 제작하여 심미적으로 환자가 만족할 수 있는 결과를 이끌어내야 한다. 이를 위해 치아 구도, 치은구도, 안면구도, 치아-안면 구도의 4가지 구도 속에서 조화를 이루는 진단 및 치료계획이 필요하다. 심미적인 욕구가 강한 경우, 주관적인 환자의 심미안을 만족시키면서 기능적인 부분을 확인하기 위해, 적절한 임시 수복물을 제작하여 기능적, 심미적 측면의 평가가 필요하다. 최종 보철물 제작에 이중 스캔을 이용하여 임시 수복물의 정보를 반영할 수 있다. 본 증례는 상악 전치부가 비심미적인 환자에서, 체계적인 심미 분석 하에 임시 수복물을 제작하고 기능적, 심미적 측면을 평가 및 수정하여, 이중 스캔을 통해 임시수복물의 정보를 최종 수복물에 반영 후 최종 수복한 증례이다.

유로만곡부의 횡방향 하상경사 산정 모형에 관한 연구 (A Study on Selected Transverse Bed Slope Models in Channel Bend)

  • 송재우;최인호;김지호
    • 대한토목학회논문집
    • /
    • 제14권6호
    • /
    • pp.1395-1404
    • /
    • 1994
  • 유로만곡부의 횡방향 하상경사는 하천형태학적 특성연구와 하도재해방지, 그리고 수공구조물 보호 등에 기초자료를 제공하는 중요한 연구과제이다. 본 연구에서는 연구대상유역 유로만곡부의 횡방향 하상경사를 Odgaard의 모형외 8개의 모형을 선택하여 비교분석한 후 예측하였으며 적합한 모형을 제시하였다. 본 연구에서 비교된 모든 모형들은 곡률반경과 수심에 비례하였고 모형들사이의 차이는 비례계수 K에 있으며 또한 측정된 횡방향 하상경사는 만곡부에서의 최대수심과 평균유속, 그리고 입자 Froude수와 관계가 있었다. 본 연구에서 Sacramento강 만곡부에서 이루어진 Odgaard의 실험자료를 이용하여 횡방향 하상경사모형들을 비교분석한 결과 Odgaard89모형이 실측횡방향 하상경사와 비교적 잘 일치하였다.

  • PDF

Evaluation of the Acromioclavicular Joint Morphology for Minimizing Subacromial Erosion after Surgical Fixation of the Joint Using a Clavicular Hook Plate

  • Kim, Sung-Jae;Kee, Young-Moon;Park, Dong-Hyuck;Ko, Young-Il;Lee, Bong-Gun
    • Clinics in Shoulder and Elbow
    • /
    • 제21권3호
    • /
    • pp.138-144
    • /
    • 2018
  • Background: Subacromial erosion remains a major concern after surgical fixation of acromioclavicular (AC) joint using a clavicular hook plate. To minimize postoperative subacromial erosion, we investigated the structural relationship between distal clavicle and acromion around the AC joint by considering the surgical fixation of the joint using the hook plate technique. Methods: Computed tomography scans of 101 AC joints without any inherent pathology were analyzed. The angle between the distal clavicle and acromion around the AC joint (AC angle), depth of the acromion, differences in height between distal clavicle and acromion (AC height difference), and thickness of distal clavicle and acromion at the AC joint were measured. Descriptive statistics were calculated for each anatomical parameter, and all results were compared between gender groups. Results: The mean AC angle was $17.1^{\circ}$(range, $-8.0^{\circ}$ to $39.0^{\circ}$), and the mean AC height difference was 3.5 mm (range, -0.7 to 8.7 mm). Both factors showed very high variability (coefficients of variation=62.6% and 46.6%, respectively). The mean AC angle was significantly higher in the female gender than in the male gender ($19.8^{\circ}$ vs. $13.8^{\circ}$, p=0.048). The mean acromion thickness and distal clavicular thickness were both significantly thinner in the female group than in the male group (p<0.001). Conclusions: Taken together, we believe our results might be helpful in minimizing postoperative subacromial erosion when performing surgical fixation of the AC joint using the hook plate, and be valuable in improving future design of the hook plate.