• 제목/요약/키워드: Design Limit Loads

검색결과 184건 처리시간 0.022초

Reliability-based design of prestressed concrete girders in integral Abutment Bridges for thermal effects

  • Kim, WooSeok;Laman, Jeffrey A.;Park, Jong Yil
    • Structural Engineering and Mechanics
    • /
    • 제50권3호
    • /
    • pp.305-322
    • /
    • 2014
  • Reliability-based design limit states and associated partial load factors provide a consistent level of design safety across bridge types and members. However, limit states in the current AASHTO LRFD have not been developed explicitly for the situation encountered by integral abutment bridges (IABs) that have unique boundary conditions and loads with inherent uncertainties. Therefore, new reliability-based limit states for IABs considering the variability of the abutment support conditions and thermal loading must be developed to achieve IAB designs that achieve the same safety level as other bridge designs. Prestressed concrete girder bridges are considered in this study and are subjected to concrete time-dependent effects (creep and shrinkage), backfill pressure, temperature fluctuation and temperature gradient. Based on the previously established database for bridge loads and resistances, reliability analyses are performed. The IAB limit states proposed herein are intended to supplement current AASHTO LRFD limit states as specified in AASHTO LRFD Table 3.4.1-1.

4인승 선미익 경항공기 전기체 정적 구조시험 (Full Scale Airframe Static Test of 4 Seater Canard Airplane)

  • 신정우;김성찬;김성준;채동철;이상욱;김태욱;심재열
    • 한국군사과학기술학회지
    • /
    • 제9권4호
    • /
    • pp.15-23
    • /
    • 2006
  • In this paper, full-scale airframe static test of 4-seater canard airplane(the Firefly) was explained. From the results of the structural analysis, 5 design limit loads test conditions and 11 design ultimate loads test conditions were selected. Test loads analysis was performed and test fixtures and load control system(LCS) were prepared to realize the test loads. To protect the test article during the test, the overload protection system was prepared. Strain and deflection values were acquired through the data acquisition system(DAS) to verify the structural analysis results.

기본훈련기 방향타 조종장치 정적하중 시험에 관한 연구 (A Study on the Static Test of Rudder Control System for a Basic Trainer)

  • 전찬원;이수용;강규섭
    • 한국항공우주학회지
    • /
    • 제30권2호
    • /
    • pp.115-121
    • /
    • 2002
  • 본 논문은 KTX-1 기본훈련기 방향타 조종계통의 정적 하중 시험을 요약한 것이다. 방향타 콘트롤 시스템 정적 하중시험은 정하중 구조 시험용 KTX-1 #004호기에 장착 상태에서 실시하였으며 사용되는 모든 부품은 실제와 동일한 것으로 장착하고 정적하중 시험을 실시하였다. 시험하중 조건은 설계 제한하중(Design Limit Load)과 설계 극한하중(Design Ultimate Load)까지 시험을 수행하며, 전방석과 후방석 패달에 동시하중을 작용하는 경우 중복하중계수(Dual Factor)까지 고려하였다. 이 시험의 요구하중은 MIL-A-8855(USAF)의 요구조건에 따라 수행하였으며, 방향타 콘트롤 시스템 시험 결과는 미 군사규격 요구조건을 만족하였다.

Mechanical architecture and loads definition for the design and testing of the Euclid spacecraft

  • Calvi, Adriano;Bastia, Patrizia
    • Advances in aircraft and spacecraft science
    • /
    • 제3권2호
    • /
    • pp.225-242
    • /
    • 2016
  • Euclid is an astronomy and astrophysics space mission of the European Space Agency. The mission aims to understand why the expansion of the Universe is accelerating and what is the nature of the source responsible for this acceleration which physicists refer to as dark energy. This paper provides both an overview of the spacecraft mechanical architecture and a synthesis of the process applied to establish adequate mechanical loads for design and testing. Basic methodologies and procedures, logics and criteria which have been used with the target to meet a compliant, "optimised" design are illustrated. The strategy implemented to limit the risk for overdesign and over-testing without jeopardizing the design margins is also addressed.

Reliability Assessments and Design Load Factors for Reinforced Concrete Containment Structures of Nuclear Power Plant

  • Han, Bong-Koo
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.444-450
    • /
    • 1997
  • The current ASME code for reinforced concrete containment structures are not based on probability concepts. The stochastic nature of natural hazard or accidental loads and the variations of material properties require a probabilistic approach for a rational assessment of structural safety and performance. The paper develops design load factors for the serviceability limit state of reinforced concrete containment structures. The target limit state probability is determined and the load factors are calculated by the numerical analysis. Design load factors are proposed and carried out the reliability assessments.

  • PDF

Influence of different fatigue loads and coating thicknesses on service performance of RC beam specimens with epoxy-coated reinforcement

  • Wang, Xiao-Hui;Gao, Yang;Gao, Run-Dong;Wang, Jing;Liu, Xi-La
    • Computers and Concrete
    • /
    • 제19권3호
    • /
    • pp.243-256
    • /
    • 2017
  • Epoxy-coated reinforcing bars are widely used to protect the corrosion of the reinforcing bars in the RC elements under their in-service environments and external loads. In most field surveys, it was reported that the corrosion resistance of the epoxy-coated reinforcing bars is typically better than the uncoated bars. However, from the experimental tests conducted in the labs, it was reported that, under the same loads, the RC elements with epoxy-coated reinforcing bars had wider cracks than the elements reinforced with the ordinary bars. Although this conclusion may be true considering the bond reduction of the reinforcing bar due to the epoxy coating, the maximum service loads used in the experimental research may be a main reason. To answer these two phenomena, service performance of 15 RC beam specimens with uncoated and epoxy-coated reinforcements under different fatigue loads was experimentally studied. Influences of different coating thicknesses of the reinforcing bars, the fatigue load range and load upper limit as well as fatigue load cycles on the mechanical performance of RC test specimens are discussed. It is concluded that, for the test specimens subjected to the comparatively lower load range and load upper limit, adverse effect on the service performance of test specimens with thicker epoxy-coated reinforcing bars is negligible. With the increments of the coating thickness and the in-service loading level, i.e., fatigue load range, load upper limit and fatigue cycles, the adverse factor resulting from the thicker coating becomes noticeable.

인공위성 노치예측해석 및 정현파가진시험 입력도출

  • 김성훈;김진희;황도순;이주훈;진익민
    • 항공우주기술
    • /
    • 제1권2호
    • /
    • pp.75-82
    • /
    • 2002
  • 본 연구에서는 인공위성의 정현파 가진시험을 위한 여러 입력, 요구조건 그리고 노치예측 해석에 대한 내용을 정리하였다. 노치예측 해석에서는 인공위성의 가진위치 하중 및 중요 내부연결점의 하중을 구하였고, 이 값들을 이용하여 각 부위의 한계하중 및 안전여유를 검토한 후 정현파 가진시험에 이용할 입력을 생성하였다.

  • PDF

유한요소 극한해석을 이용한 소성변형에서의 구조물의 위상최적화 (Topology Optimization of Structures in Plastic Deformation using Finite Element Limit Analysis)

  • 이종섭;허훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.603-608
    • /
    • 2008
  • It is well known that the topology optimization for plastic problem is not easy since the iterative analyses to evaluate the objective and cost function with respect to the design variation are very time-consuming. The finite element limit analysis is an efficient tool which is possible to predict collapse modes and sequential collapse loads of a structure considering not only large deformation but also plastic material behavior with moderate computing cost. In this paper, the optimum topology of a structure considering large and plastic deformation is obtained using the finite element limit analysis. To verify the constructed optimization code, topology optimizations of some typical problems are performed and the optimal topologies by elastic design and plastic design are compared.

  • PDF

Multicut high dimensional model representation for reliability analysis

  • Chowdhury, Rajib;Rao, B.N.
    • Structural Engineering and Mechanics
    • /
    • 제38권5호
    • /
    • pp.651-674
    • /
    • 2011
  • This paper presents a novel method for predicting the failure probability of structural or mechanical systems subjected to random loads and material properties involving multiple design points. The method involves Multicut High Dimensional Model Representation (Multicut-HDMR) technique in conjunction with moving least squares to approximate the original implicit limit state/performance function with an explicit function. Depending on the order chosen sometimes truncated Cut-HDMR expansion is unable to approximate the original implicit limit state/performance function when multiple design points exist on the limit state/performance function or when the problem domain is large. Multicut-HDMR addresses this problem by using multiple reference points to improve accuracy of the approximate limit state/performance function. Numerical examples show the accuracy and efficiency of the proposed approach in estimating the failure probability.

균열을 가진 강구조부재의 한계하중에 대한 유한요소해석 (Finite Element Analysis of Cracted Structural Steel Member)

  • 박용걸
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.123-126
    • /
    • 1995
  • The purpose of the analysis is the numerical simulation of structures strained to the limit loads. The finite element calculations and experiments with cracked structures have been carried out yielding over limit strains between 10% and 15% by single peak load. Load versus displacement-diagrams and J-diagrams up to the limit load are calculated. By this way the influence of geometric parameters may be assessed in the post yield region. It is proposed to use such calculations to correlate experiments carried out with small specimens to experiments simulating the true dimensions of the design structure.

  • PDF