• 제목/요약/키워드: Design Guidance

검색결과 932건 처리시간 0.028초

무선 센서네트워크를 이용한 애완견용 무선 관리 시스템의 설계 및 구현 (Design and Implementation of Wireless Management System for Pet Dog Using Wireless Sensor Network)

  • 김동성
    • 정보통신설비학회논문지
    • /
    • 제7권1호
    • /
    • pp.1-13
    • /
    • 2007
  • This paper proposes a wireless management system for a pet dog using wireless sensor network. The developed intelligent wireless management system is compose of a central control system, auto-feeder, mini-guidance robot, and wireless sensing devices. The developed system uses three types of sensed data such as light, temperature, and sounds from a pet dog and surrounded environment respectively. The presented design method using these data provides an efficient way to controlling and monitoring the pet dog. The implemented system can be used as a design framework of portable device for the pet management.

  • PDF

Cross-section classification of elliptical hollow sections

  • Gardner, L.;Chan, T.M.
    • Steel and Composite Structures
    • /
    • 제7권3호
    • /
    • pp.185-200
    • /
    • 2007
  • Tubular construction is widely used in a range of civil and structural engineering applications. To date, the principal product range has comprised square, rectangular and circular hollow sections. However, hot-rolled structural steel elliptical hollow sections have been recently introduced and offer further choice to engineers and architects. Currently though, a lack of fundamental structural performance data and verified structural design guidance is inhibiting uptake. Of fundamental importance to structural metallic design is the concept of cross-section classification. This paper proposes slenderness parameters and a system of cross-section classification limits for elliptical hollow sections, developed on the basis of laboratory tests and numerical simulations. Four classes of cross-sections, namely Class 1 to 4 have been defined with limiting slenderness values. For the special case of elliptical hollow sections with an aspect ratio of unity, consistency with the slenderness limits for circular hollow sections in Eurocode 3 has been achieved. The proposed system of cross-section classification underpins the development of further design guidance for elliptical hollow sections.

Stochastic Design Approach for the Guidance and Control System of an Automatic Landing Vehicle

  • Minami, Yoshinori;Miyazawa, Yoshikazu;Shimada, Yuzo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.41-46
    • /
    • 1998
  • In this paper, a stochastic approach based on a Monte Carlo simulation method for the design of a guidance and control (G & C) system of an automatic landing flight experiment (ALFLEX) vehicle is presented. The aim of this study is to design a G & C system robust against uncertainties in the vehicular dynamics. In this study, uncertain parameters and disturbances are treated as random variables in the Monte Carlo simulation. Then, some controller gains in the G & C system are tuned to satisfy conditions concerning the states at touchdown. The proposed method was applied to the ALFLEX vehicle. The simulation results shored the effectiveness of the present approach.

  • PDF

초고층 건축물의 화재안전성능 표준화 구축 (Establishment of Performance Based Design Standardization of Fire Protection Systems for High-Rise Buildings)

  • 손봉세
    • 한국재난정보학회 논문집
    • /
    • 제5권1호
    • /
    • pp.66-74
    • /
    • 2009
  • As building heights increase, so do these challenges in Korea. High-rise buildings present a variety of challenges to fire safety and protection. The fire protection technology in our country is still on a weak situation which is mainly due to the lack of concerns by the government, companies and citizen. This paper provides general guidance regarding fire-related property protection system for high-rise building performance based design. The importance of high-rise building in of the number of occupants, the value of property, and the a catastrophic loss would have on the community all warrant an increased level of protection and life safety. Because, We have to prepare a new spacial code and standard guidance for fire protection at the stage of the high-rise building design.

  • PDF

Some Considerations for the Fire Safe Design of Tall Buildings

  • Cowlard, Adam;Bittern, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.63-77
    • /
    • 2013
  • In any subject area related to the provision of safety, failure is typically the most effective mechanism for evoking rapid reform and an introspective assessment of the accepted operating methods and standards within a professional body. In the realm of tall buildings the most notable failures in history, those of the WTC towers, widely accepted as fire induced failures, have not to any significant extent affected the way they are designed with respect to fire safety. This is clearly reflected in the surge in numbers of Tall Buildings being constructed since 2001. The combination of the magnitude and time-scale of the WTC investigation coupled with the absence of meaningful guidance resulting from it strongly hints at the outdatedness of current fire engineering practice as a discipline in the context of such advanced infrastructure. This is further reflected in the continual shift from prescriptive to performance based design in many parts of the world demonstrating an ever growing acceptance that these buildings are beyond the realm of applicability of prescriptive guidance. In order for true performance based engineering to occur however, specific performance goals need to be established for these structures. This work seeks to highlight the critical elements of a fire safety strategy for tall buildings and thus attempt to highlight some specific global performance objectives. A survey of tall building fire investigations is conducted in order to assess the effectiveness of current designs in meeting these objectives, and the current state-of-the-art of fire safety design guidance for tall structures is also analysed on these terms. The correct definition of the design fire for open plan compartments is identified as the critical knowledge gap that must be addressed in order to achieve tall building performance objectives and to provide truly innovative, robust fire safety for these unique structures.

거주성 관점의 미국 이재민 임시대피시설 공간계획 관련 지침분석 (Analysis of the Space Planning Guidance about the Temporary Shelter Emphasizing Habitability for Disaster Victims in U.S.)

  • 김미경;최선미;최유라
    • 한국실내디자인학회논문집
    • /
    • 제26권5호
    • /
    • pp.42-51
    • /
    • 2017
  • The purpose of this study was to analyze the information about the disaster temporary shelter space planning guidance described in the U.S. shelter guidelines in terms of the habitability for disaster victims and to address the implications and potential impacts of its findings for the improvement of the shelter design standards and guidelines in Korea. The researchers reviewed four federal and non-governmental organization shelter field and design guidelines and attributes regarding the shelter space planning were classified in accordance with four habitability categories: Safety, Health, Convenience, and Comfort. Three major findings emerged from this study: 1)A total of 72 items about the shelter space planning were extracted from guidelines, and the majority of items are concerned with dormitory areas and sanitary spaces. Other items were about accessibility, children respite care area, signage, health service areas, food preparation and serving areas, parking and drop-off areas, registration and waiting areas, shelter manager and staff areas, lounge and storage areas, and household pets area. 2)Most of these items are strongly related to the convenience category(66.7%), followed by comfort(40.3%), safety(30.6%), and health(25.0%). 3)The habitability of the disaster temporary shelter can be established with considerations on the needs of disaster victims and vulnerable people, minimum occupancy space per person, separate sanitary spaces for the privacy, safe and convenient access routes to the shelter, and the provision of children areas for safety and comfort. The study findings will contribute to the development of the disaster shelter guidelines in Korea by suggesting shelter space planning indicators related to the habitability for the governmental and non-governmental organizations' immediate and systematic responses to the disaster.

재진입비행체의 궤적제어 (Trajectory Control for Re-entry Vehicle)

  • 박수홍;이대우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 1997
  • The re-enty guidance design involves trajectory optimization, generation of a reference drag acceleration profile with the satisfaction of trajectory constraints. This reference drag acceleration profile can be considered as the reference trajectory. This paper proposes the atmospheric re-entry system which is composed of longitudinal, later and range control. This paper shows the a performance of a re-entry guidance and control system using feedback linearization control and predictive control.

  • PDF

루프형성 기법을 이용한 편심배치방식 자기부상 시스템의 강인 LQ 제어 (Robust LQ control of magnetically levitation systems with a combined lift and guidance using loop-shaping techniques)

  • 박전수;김종식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.747-753
    • /
    • 1992
  • The modeling and control design schemes are developed for maglev systems with a combined lift and guidance. First, bond graph techniques are applied for modeling these multi-energy domain systems more logically and systematically. And the stability loop via pole placement and the performance loop via loop-shaping LQ control are designed. The suggested controller satisfies the required characteristics of stability and performance simultaneously. Finally, the robustness of the synthesized maglev control system is evaluated for the variations of air gap and vehicle mass through computer simulation.

  • PDF