• Title/Summary/Keyword: Design Demonstration

Search Result 404, Processing Time 0.024 seconds

Design and Fabrication of Technology Demonstration Model of 75 tonf Regenerative Cooling Thrust Chamber (75톤급 재생냉각 연소기 기술검증용 시제 설계 및 제작)

  • Kim, Jong-Gyu;Ahn, Kyu-Bok;Lim, Byoung-Jik;Kim, Mun-Ki;Kang, Dong-Hyuk;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.31-34
    • /
    • 2011
  • Design and fabrication of Technology Demonstration Model(TDM) of 75 tonf regenerative cooling thrust chamber were described. It has design chamber pressure of 60 bar, propellant mass flow rate of 243.6 kg/s, and nozzle expansion ratio of 12. It has a single welded structure of the mixing head and the chamber. Design and fabrication technologies established through this TDM can be used to development of flight model.

  • PDF

BIPV System Design to Enhance Electric Power Generation by Building up a Demonstration Mock-up and Analyzing Statistical Data (실증 목업의 구축 및 데이터의 통계적 분석을 통한 건물일체형 태양광 발전시스템의 전력발전 향상 설계)

  • Lee, Seung-Joon;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.587-599
    • /
    • 2018
  • In building-integrated photovoltaic (BIPV) systems, power generation functions are integrated into building functions by installing solar modules in combination with building materials. While this integration appears to be attractive, a design method is needed to achieve maximum power generation. Previously, the influence of the design elements on power generation was analyzed by computer simulations and demonstration tools. On the other hand, problems remain due to the inaccuracy of power generation analysis and relationship analysis, and limited demonstration. To solve this problem, this paper proposed the use of an extended demonstration mock-up. The mock-up was designed and constructed by implementing the design elements of the module types, installation angles, and direction. The actual operation data for one year were analyzed to evaluate the effects of the design elements on power generation. These results can be used to determine the feasibility of future BIPV systems and the optimal selection of system design elements.

Characteristics and Strategy of Sales Promotion for On-line Fashion SOHO Shopping Mall (온라인 패션 SOHO 쇼핑몰의 판매촉진특성 및 판매촉진전략)

  • Ji, Hye-Kyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.10 no.2
    • /
    • pp.163-178
    • /
    • 2008
  • The purpose of this study is to search the characteristics and strategy of sales promotion in on-line fashion SOHO (Small Office Home Office) shopping malls. 87 of these shopping malls have been selected through a ranking service called 100HOT (http://www.100hot.co.kr), and 906 cases of sales promotion activities have been executed on web-sites of these shopping malls. The cases have been analyzed by descriptive statistics and chi-square analysis. The results are as follows: First, on-line fashion SOHO shopping malls have frequently used sales promotion tactics such as demonstration, display, viral marketing, sale, event, customer compensation, community marketing, experimental marketing, coupon, premium, reserve fund and delivery service. Second, there are significant differences between shopping malls for men and women in sales promotion tactics such as demonstration, viral marketing, sale, and community marketing, but there is no significant difference in tactics such as demonstration, event, and customer compensation. Third, the shopping malls have used various sales promotion strategies such as maximizing the sales, characterizing product features, procuring new customers, preserving existing customers, enhancing customer loyalty, improving customer relationship and controlling returns.

  • PDF

Numerical Simulation of a 100 $MW_e$-scale Wall-fired Boiler for Demonstration of Oxy-coal Combustion (전산유동해석을 이용한 100 $MW_e$급 석탄 순산소 연소 실증 보일러의 설계 및 운전조건 평가)

  • Chae, Tae-Young;Park, Sang-Hyun;Hong, Jae-Hyeon;Yang, Won;Lee, Sang-Hoon;Ryu, Chang-Kook
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • As one of the main technologies for carbon capture and storage in power generation, oxy-coal combustion is being developed for field demonstration in Korea. This study presents the results of numerical simulation for combustion in a single-wall-fired 100 $MW_e$-scale boiler proposed for the initial design of the demonstration plant. Using a commercial CFD code, the detailed combustion, flow and heat transfer characteristics were assessed both for air-mode and oxy-mode combustion. The results show that stable combustion can be achieved in the dual mode operation with the current boiler configuration. However, the differences in the flow pattern and heat transfer between the two combustion modes need to be considered in the design and operation which is mainly due to the larger density and specific heat of $CO_2$ compared to $N_2$. Further development of the boiler design is required using improved numerical modeling for radiative heat transfer and combustion.

Health Behaviors between a Health Promotion Demonstration Health Center and a General Health Center (건강증진사업 시범여부에 따른 지역주민의 사업인식과 참여도, 건강행위 비교 연구)

  • Lee Taewha;Lee Chung-Yul;Kim Hee-Soon;Ham Ok-Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.3
    • /
    • pp.461-468
    • /
    • 2005
  • Purpose: The purpose of the study was to compare community residents' perceptions, participation, satisfaction, and behavioral changes between a health promotion demonstration health center and general health center. Method: The design of the study was ex-post facto that compared community residents in demonstration health centers and general health centers. The sample included 2,261 community residents who were conveniently selected from demonstration (792 participants) and general health centers (1,496 participants). Result: The results of the study were as follows: 1) Perception and participation rates of exercise, nutrition, and hypertension management programs were significantly higher in the participants of demonstration health centers than those of general health centers.; 2) Satisfaction rates of all programs except the smoking cessation program were significantly higher in the participants of demonstration health centers than those of general health centers. However, only the exercise rate among risk behaviors of participants was significantly higher in demonstration health centers than general health centers. Conclusion: Systematic efforts for health promotion were effective not only in improving the community's awareness, participation, and satisfaction of the program, but also in changing health behaviors. This evidence should be used to foster and disseminate health promotion programs toother health centers to improve community residents' health status and quality of life.

The Optimal Operation Condition and Estimation Performance for 300MW Demonstration Gasifier (300MW급 실증 가스화기의 최적 운전조건 및 성능 예측)

  • Yoo, Jeong-Seok;Koo, Ja-Hyung;Paek, Min-Su;Lee, Hwang-Jik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.368-371
    • /
    • 2008
  • The optimal operation condition of gasifier is one of the most important parameters to increase efficiency and reliability in IGCC plant. Also the prediction of the syngas composition and quantity must be predicted to carry out process design of the gasification plant. However, the gasifier process licensor are protective with information on process design and optimal gasifier design conditions. So, the most of process studies in the engineering company for gasification plant have carried out to look for key parameters and optimal design conditions using several prediction methods. In this paper, we present the estimated preliminary optimal operation condition of the 300MW Demonstration Entrain Flow Gasifier using Aspen Plus. The gasifier operation temperature considering slag flow was predicted by FactSage software and Annen Model.

  • PDF

COMPARISON OF THE DECAY HEAT REMOVAL SYSTEMS IN THE KALIMER-600 AND DSFR

  • Ha, Kwi-Seok;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.535-542
    • /
    • 2012
  • A sodium-cooled demonstration fast reactor with the KALIMER-600 as a reference plant is under design by KAERI. The safety grade decay heat removal system (DHRS), which is important to mitigate design basis accidents, was changed in the reactor design. A loss of heat sink and a vessel leak in design basis accidents were simulated using the MARS-LMR system transient analysis code on two plant systems. In the analyses, the DHRS of KALIMER-600 had a weakness due to elevation of the overflow path for the DHRS operation, while it was proved that the DHRS of the demonstration reactor had superior heat transfer characteristics due to the simplified heat transfer mechanism.

A Study on Development and Use of a Demonstration-Based Architectural Design Class Operation Model for Improving Architectural Thinking Abilities of Under-Motivated Learners (건축설계 학습부진자들의 건축적 사고 개선을 위한 데모 기반 설계수업 운영모형 개발 및 활용 사례연구)

  • Lee, Do-Young;Chung, Hyun-Mi
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.3
    • /
    • pp.49-58
    • /
    • 2020
  • Based on Merrill's instructional theory, this study pursued to develop a demonstration-based architectural design class operation model for the 3rd year undergraduate students taking a Spring semester design studio class. The model was designed and used particularly to improve architectural thinking abilities of under-motivated learners. Learning effects of the model were examined based on the preliminary data obtained for 3 consecutive years, 2017 through 2019. A total of 52 students were participated in the class and observed by the instructor. Once developed, the model has been continually updated and improved based on results of each class operation. Five types of demo. were used in the model. First, direct contacts of the instructor with under-motivated learners were turned out to be the most preferred demo(demo. 4), while watching and listening of the demo(demo.3) between the instructor and motivated learners taking place in class was ranked at the second place. Belief of under-motivated learners on the instructor as a professional should be highly valued for improving their architectural thinking abilities. Second, motivated peers' direct help for under-motivated ones was placed in the third rank. Social attitudes of under-motivated learners towards accepting motivated ones' helps were determined the particular demo's appropriateness. Third, a set of guidelines for operating the model in undergraduate design studio classes were developed and suggested.

Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry (전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구)

  • Kim, ByeongMan;Lee, KilSong;Yang, YeonWon;Shin, HyunWoo;Kim, EuiHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF