• 제목/요약/키워드: Desiccant Air Conditioning System

검색결과 62건 처리시간 0.028초

액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구 (Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer)

  • 최광환;윤정인;김보철
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

Fundamental Study on the Probability of Oyster Shell Desiccant Cooling System Driven by Renewable Energy of Photo-Voltaic Effect

  • Kim, Myoung-Jun;Yu, Jik-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.387-393
    • /
    • 2008
  • This paper has dealt with the probability of oyster shell desiccant cooling system driven by renewable energy of photo-volatic effect with fundamental experiment. The test materials for desiccant are activated charcoal, silica-gel, hi-dry, and oyster shell. The experiments were mainly performed with focusing on the observation of surface features, adsorption amounts of the adsorbent species, and the effect of temperature. Oyster shell has sufficient probability for using as desiccant in a air-conditioning system. Moreover, the heat releasing device would be attached in the system, the system based with oyster shell can be operated with high efficiency.

휜-튜브형 액체건조제 제습기의 높이에 따른 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics with Height of a Fin-Tube Liquid Desiccant Dehumidifier)

  • 이수동;박문수;정진은;최영석
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.594-603
    • /
    • 2004
  • Several desiccant cooling systems have been developed in terms of cost and performance. In this study a fin-tube exchanger has been used for liquid desiccant dehumidification system. This dehumidifier has been designed to study the absorption characteristic of the aqueous triethylene glycol(TEG) solution which has the flow range from 20 to 50 LPM. The dehumidifier performance characteristics of working factor variables such as inlet solution flow rate, air flow rate, solution concentration and brine temperature have been analyzed. This dehumidifier has the ability to provide running while saving the latent heat load of total energy. The result of this experiment can provide useful data for hybrid air conditioning system.

복합형 냉풍건조기 실험에 대한 검토 (Study in the Mixed Cooling Dryer Experiment)

  • 최진영;김세환;박승태;이정호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.254-259
    • /
    • 2009
  • The mixed cooling dryer has been developed significantly by adopting both advantages of cooling dryers and desiccant dryers. In this study, it is introduced that the desired effect, such as drying rate period reduction and energy-saving, could be achieved only by adding the desiccant dryer if an existing cooling dryer is used. The experiment should be conducted for quite long time due to the material selection, so it is regrettable that there are not enough data.

  • PDF

외기 전용 공조기의 동특성 시뮬레이션 (Dynamic Simulation of a Dedicated Outdoor Air-conditioning System)

  • 김정민;김영일;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF

가열원관군 주위를 유동하는 굴패각의 탈착과정에 대한 열 및 물질전달에 관한 연구 (Study on the Heat and Mass Transfer Characteristics of Oyster Shell Flowing through the Bundle of Heating Pipes)

  • 김명준
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.28-34
    • /
    • 2013
  • This study is experimentally performed for using the oyster shell as a desiccant in the fluidized bed with bundle of heating pipe. The test material is oyster shell from fishery wastes which can use without costs. The main parameters of experiment are inlet air temperature, velocity of inlet air and heat flux of heating pipes. Also the geometry of heating pipe is treated as important parameter. From this study, the effect of inlet air temperature and input heat flux have much affect to increase the heat and mass transfer. On the other hand, the effect of inlet air velocity has less affect to increase the heat and mass transfer. And it is clarified that the oyster shell has sufficient probability for using as a desiccant in air-conditioning system.

빙상경기장의 공조시스템 분석에 관한 연구 (A Study on Analysis of Air Conditioning System in Ice Rinks)

  • 채문병;윤해동;이종신;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.441-446
    • /
    • 2009
  • A modern industrial society is presently considering not only cultural life but also health promotion to enhance the quality of life. There are many ways to enjoy the wellbeing life. Especially, ice-skating has been focused on as leisure sports with many remarkable advantages. Even though ice-skating was recognized as winter sport, nowadays people enjoyed skating are increased more and more because of indoor ice link. So, construction of indoor ice link has been boomed up. However, The techniques of ice link freezing system are insufficient because the ice link freezing system on the local construction was designed by advanced country techniques. So, this study has been conducted to analyze the air conditioning and refrigeration system in existing local ice link to suggest the design method of ice link.

  • PDF

중앙공조 및 개별공조에서의 외조기 적용 (Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning)

  • 박승태;김영일;이태호;최세영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF