• 제목/요약/키워드: Desalination Technology

검색결과 204건 처리시간 0.027초

Recent Progress of Membrane Technology and its New Application for Water Treatment

  • Hiroyuki, Yamamura;Yoshinari, Fusaoka;Masaru, Kurihara
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.81-94
    • /
    • 1998
  • Nowadays, membrane separation such as reverse osmosis (RO) and ultrafiltration (UF) play an important role in the industrial separation technology. Among desalination technologies available today, reverse osmosis is usually the most economical process for wide range of water salinity. Main applications include production of high purity water, desalination of seawater and brackish water for a drinking water supply, treatment of waste water for environmental protection, and recovery of precious materials from industrial waste water. In this paper, we will mention membrane performance and these practical use focused on reverse osmosis membranes and ultrafiltration membranes recently developed by Toray.

  • PDF

Fouling resistant membrane tailored by polyethylene glycol in oxidative environment for desalination

  • Kavaiya, Ashish R.;Raval, Hiren D.
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.381-385
    • /
    • 2019
  • Surface modification is very efficient and scalable approach to achieve improved membrane performance. We treated Reverse Osmosis Thin Film Composite (TFC RO) membrane with various concentrations of Polyethylene Glycol (PEG), a hydrophilic polymer after activation with sodium hypochlorite. This treatment resulted in an increment of the water flux by 43% and the salt rejection by 2.36% for the 3000 mg/l PEG-treated membrane. Further, these PEG-treated membranes were exposed to a mixture of 3000 mg/l PEG and 1000 mg/l sodium hypochlorite for 1 hour. Further modification of this membrane by PEG and sodium hypochlorite mixture increased the water permeance up to 133% when compared with the virgin TFC RO membrane. We characterized the treated membranes to understand the changes in wettability by contact angle analysis, changes in surface morphology and roughness by scanning electron microscope (SEM) and atomic force microscope (AFM) analysis.

Heat and mass transfer analysis in air gap membrane distillation process for desalination

  • Pangarkar, Bhausaheb L.;Sane, Mukund G.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.159-173
    • /
    • 2011
  • The air gap membrane distillation (AGMD) process was applied for water desalination. The main objective of the present work was to study the heat and mass transfer mechanism of the process. The experiments were performed on a flat sheet module using aqueous NaCl solutions as a feed. The membrane employed was hydrophobic PTFE of pore size 0.22 ${\mu}m$. A mathematical model is proposed to evaluate the membrane mass transfer coefficient, thermal boundary layers' heat transfer coefficients, membrane / liquid interface temperatures and the temperature polarization coefficients. The mass transfer model was validated by the experimentally and fitted well with the combined Knudsen and molecular diffusion mechanism. The mass transfer coefficient increased with an increase in feed bulk temperature. The experimental parameters such as, feed temperature, 313 to 333 K, feed velocity, 0.8 to 1.8 m/s (turbulent flow region) were analyzed. The permeation fluxes increased with feed temperature and velocity. The effect of feed bulk temperature on the boundary layers' heat transfer coefficients was shown and fairly discussed. The temperature polarization coefficient increased with feed velocity and decreased with temperature. The values obtained were 0.56 to 0.82, indicating the effective heat transfer of the system. The fouling was observed during the 90 h experimental run in the application of natural ground water and seawater. The time dependent fouling resistance can be added in the total transport resistance.

증발식 해수담수화설비의 에너지 소모량에 관한 연구 (A study on the required energy of a thermal type desalination plant)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1094-1100
    • /
    • 2014
  • 오폐수처리, 해수담수화 및 식품산업의 경우 증발과정은 필수공정이며, 이는 기본적으로 용액으로부터 용매인 순수한 물성분을 추출하여 점차 용액의 농도를 증가시키는 방식이다. 농축을 위한 방식은 전기투석, 증발식, 막방식 등의 다양한 방법이 사용되고 있으나, 본 연구에서는 여러 산업분야에서 적용되고 있는 증발식을 대상으로 운전방식에 따른 가열열원의 소모량을 이론적으로 분석하고, 이에 근거하여 다단증발식 해수담수화설비의 운전특성을 파악하였다. 본 연구의 결과에 따르면 시스템에서 이용할 수 있는 전체 온도차, 즉 인입해수의 온도와 1단 증발부로 유입되는 해수온도와의 차를 기준으로 증발단의 수를 증가시킬수록 에너지효율이 상승함을 알 수 있었다.

해수 담수화 플랜트 제어 시스템 구성 방안 연구 (A Study on Automatic Control Systems for Seawater Desalination Plants)

  • 주영덕;김경범;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.3-9
    • /
    • 2008
  • Recently, the plant industries are being activated and plant control systems use various technologies. Because the optimized design for the plants is very important for the reducing of operation and maintenance costs, automatic control systems become more important. Plant control systems consist of the master controller, the plant networks, the programming environment for engineering, monitoring software and the field devices. The control systems should have reliability, availability and safety. Modular architecture of hardware and software makes flexible configuration of the control systems. Each component should have diagnostic functions. It follows industrial standards and makes open systems. Open systems increase accessibility against the data which is distributed in the plants. The controllers including processor and communication modules use the up-to-date technology. They have real time and fault tolerant function by duplicating processors or networks. It also enables to make the distributed control systems. The distributed architecture makes more scalable main control system. Automatic control systems can be operated with better performance. In this paper, we analyzed the requirements of the seawater desalination plants and made some consideration facts for developing the optimized controller. Also we described the design concept of the main controller, which consists of several modules. We should validate and complement the design for the reliability and better performance.

  • PDF

역삼투법 해수담수화 전처리 여과공정의 최적조건 (Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis)

  • 김승현;윤종섭;이석헌
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

알칼리 수용액을 이용한 출토 철지금은장관정의 탈염처리 적용성 평가 (A Study on the Stability of Using Alkali Solution Desalination on Gilt Plated Silver-Iron Artifacts)

  • 박준현;배고운;정광용
    • 보존과학회지
    • /
    • 제37권2호
    • /
    • pp.179-189
    • /
    • 2021
  • 부여 능산리 서고분군에서 출토된 철지금은장관정을 대상으로 도금된 철제유물의 탈염 가능성 및 안정한 탈염방법을 연구하였다. 철지금은장관정은 철을 소지금속으로 하여 은판을 열로 접합시킨 후 그 위에 아말감도금으로 제작한 유물이다. 본 유물은 균열 및 박락된 부위 틈 사이로 철 부식화합물이 다른 재질의 금속(Au, Ag) 표면에 고착되어 있어 탈염이 필요하다고 판단했다. 따라서 금은장부 잔존 상태별로 A·B·C등급으로 분류하고 60℃에서 0.1M 알칼리 용액법인 NaOH법과 S.S.C법으로 탈염을 진행하였다. Cl- 용출량과 탈염기간은 A등급을 제외하고 NaOH법이 S.S.C법보다 더 많은 양을 용출하였고 기간도 더 소요되었다. 탈염 전·후 금은장부의 Fe 성분을 비교하면 B등급을 제외하고 NaOH법이 S.S.C법에 비해 증가폭이 작았으나 NaOH법으로 탈염한 관정 4점의 금은장부가 일부 파손되어 유물의 안정성을 고려했을 때, S.S.C법으로 탈염하는 것이 안정할 것으로 판단된다.

상업용 정밀여과/한외여과막의 특성 분석 및 해수 여과 성능 평가 (Characterization and Seawater Filtration Performance of Commerical Microfiltration and Ultrafiltration Membranes)

  • 최창규;김인수
    • 대한환경공학회지
    • /
    • 제39권9호
    • /
    • pp.542-547
    • /
    • 2017
  • 본 연구는 국내에서 상용화된 3 종류의 친수성 정밀여과막/한외여과막을 대상으로 막의 특성분석 및 해수 여과 성능 평가를 수행하였다. 접촉각 측정 결과에서는 PAN 재질인 Mem-3가 가장 친수성도가 높은 것으로 나타나 장기간 운전 시 유기성 오염 물질에 가장 내오염성이 높을 것으로 예상된다. FESEM 측정결과에서는 PE 재질인 Mem-1과 PVDF 재질인 Mem-2는 sponge 형태의 단면을 보였으며, PAN 재질인 Mem-3는 finger 형태의 단면을 나타냈다. EDS에 의한 막의 원소분석 결과에서 Mem-2는 Fluoride가 대부분이었고 Mem-3는 PAN이 Nitrile기로 인해 N이 32.47%의 높은 구성 비율을 보였다. D.I. water를 이용한 투과수량 분석은 압력 증가 시 Mem-3의 투과수량이 다른 막에 비해 큰 폭으로 증가되는 경향을 보였다. 탁도 및 부유물질 제거 실험은 모든 막에서 유출수의 탁도는 0.191-0.406 NTU, TSS는 2.2-3.0 mg/L 사이의 투과수질을 보여 단기간 실험으로부터 해수담수화 전처리용으로 사용하기에는 부적합하다는 것을 알 수 있었다.

지열에너지와 진공 막 증류법을 활용한 해수담수화 연계형 공정의 경제성 분석 (Economic Analysis of Geothermal Energy and VMD Desalination Hybrid Process)

  • 박기호;김진현;김혁수;이관영;양대륙;김경남
    • 청정기술
    • /
    • 제20권1호
    • /
    • pp.13-21
    • /
    • 2014
  • 최근 도서지역 지하수의 염분증가로 인해 지하수가 점차 생활용수로 부적합해 짐에 따라 해수담수화의 필요성이 크게 대두되고 있다. 이러한 해수담수화를 수행하기 위해서는 많은 에너지 비용이 들어가는데, 최근 에너지가격의 상승으로 경제성 확보가 어려운 실정이다. 지열에너지를 활용한 연계형 플랜트가 문제를 해결하는 중요한 방법이 될 수 있다. 지열시스템은 지구 내부의 온도를 이용하는 방법으로서 항상 온도가 일정하며 24시간 활용할 수 있어 이용률이 높다는 장점이 있기 때문이다. 본 연구에서는 지열을 보조열원으로 활용한 진공 막 증류법 해수담수화 플랜트를 설계하고, 지열과 연계하지 않은 일반 진공 막 증류법 해수담수화 플랜트와 경제성 비교분석을 했다. 그 결과 할인율 5%일 경우 지열연계형이 $23,822,409 만큼 더 높은 순현재가치 값을 가지며, 운영기간 5.36년을 분기점으로 두 플랜트의 현금흐름이 역전되어 지열연계형 플랜트가 일반 진공 막 증류법 해수담수화 플랜트보다 더 큰 경제성을 갖는 결과를 얻었다. 또한 민감도 분석에서 주요 변수들간의 결과값 비교를 한 결과, 스팀이용비용의 변동폭이 가장 큰 영향을 미친 점에 비추어 스팀비용이 높은 지역일수록 지열에너지 연계형 플랜트가 경제적이고 효과적인 솔루션인 것으로 증명되었다.

온도와 압력 변화가 압력지연삼투 공정 성능에 미치는 영향 (Effect of the Temperature and Pressure on Pressure Retarded Osmosis Performance)

  • 심진우;남숙현;구재욱;김은주;윤영한;황태문
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.321-325
    • /
    • 2016
  • The Pressure Retarded Osmosis (PRO) is the next generation desalination technique and is considered as a eco-friendly energy. This was conducted to evaluate the effect of the temperature and pressure on the PRO performance. The flux of the permeation was measured under different operating conditions and estimated the power density. An improvement of PRO performance is depend on increasing solution temperature and optimum pressure. The effect of increasing feed solution temperature has stronger impact on the PRO performance comparing to the draw solution temperature. The reason of the results was due to the change of osmotic power, viscosity, water permeability and structure parameter(s).