• Title/Summary/Keyword: Depth correction

Search Result 299, Processing Time 0.021 seconds

Single-Phase SRM Driving Method for Power Factor Correction (단상 SRM의 역률 개선을 위한 구동방식)

  • Ahn Jin-Woo;Park Sung-Jun;Son Ick-Jin;Oh Seok-Gyu;Hwang Young-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.235-238
    • /
    • 2001
  • A novel single-stage power factor corrected (PFC) drive for switched reluctance motor (SRM) is presented to achieve sinusoidal, near unity power factor input current. The proposed PFC SRM drive has no additional active switch. And a single-stage approach, which combines a DC link capacitor used as dc source and a drive used for driving the motor into one power stage, has a simple structure and low cost. The characteristics and validity of the proposed circuit will be discussed in depth through the experimental results.

  • PDF

Dose Characteristics of Small Radiation Fields for 6MV X-ray of Linear Accelerator (선형가속기의 6MV X선에 대한 소형조사면의 선량측정)

  • Choi, Tae-Jin;Kim, Ok-Bae;Kim, Young-Hoon;Son, Eun-Ik;Kim, In-Hong
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.287-291
    • /
    • 1989
  • Radiation dosimetry has been extended to small fields less than $4\times4cm^2$ which may be suitable for irradiation of small intracranial tumors. Special consideration was given to the percentage depth dose and scatter correction factors with 0.14ml ion chamber, film dosimetry and TLD measurement. Calculated dose distributions were compared with measured data.

  • PDF

A Study on the Correction of Face Motion Recognition Data Using Kinect Method (키넥트 방식을 활용한 얼굴모션인식 데이터 제어에 관한 연구)

  • Lee, Junsang;Park, Junhong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.513-515
    • /
    • 2019
  • Techniques to recognize depth values using Kinect infrared projectors continue to evolve. Techniques to track human movements are being developed from the Marcris method to the Bimarris method. Capture of facial movement using Kinect has disadvantages that are not sophisticated. In addition, a method to control the gestures and movements on the face in real time requires much research. Therefore, this paper proposes a technique to create natural 3D image contents by studying technology to apply and control branding technology to extracted face recognition data using Kinect infrared method.

  • PDF

Asymmetric Threshold-Based Occupancy Map Correction for Efficient Coding of MPEG Immersive Video (MIV 의 효율적인 부호화를 위한 비대칭 임계값 기반 점유맵 보정)

  • Dong-Ha Kim;Sung-Gyun Lim;Jeong-yoon Kim;Jae-Gon Kim
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.11a
    • /
    • pp.51-53
    • /
    • 2022
  • MIV(MPEG Immersive Video)의 시험모델 TMIV 는 다시점의 비디오와 깊이(depth) 비디오를 입력 받아 시점 사이의 중복성을 제거한 후 남은 텍스처(texture)와 깊이로 텍스처 아틀라스(atlas)와 깊이 아틀라스를 각각 생성하고 이를 압축한다. 각 화소별 점유(occupancy) 정보는 깊이 아틀라스에 포함되어 압축되는데 압축 손실로 인한 점유맵 오류를 방지하기 위하여 임계값 T = 64 로 설정한 보호대역을 사용한다. 기존에 설정된 임계값을 낮추어 깊이 동적범위를 확대하면 보다 정확한 깊이값 표현으로 부호화 효율을 개선할 수 있지만 보호대역 축소로 점유맵 오류가 증가한다. 본 논문에서는 TMIV 의 부호화기와 보호화기에 비대칭 임계값을 사용하여 보호대역 축소로 인한 점유맵 오류를 보정하면서 보다 정확한 깊이 값 표현을 통하여 부호화 효율을 개선하는 기법을 제안한다. 제안기법은 깊이 동적범위 확대와 비대칭 임계값 기반의 점유맵 오류 보정을 통하여 CG 시퀀스에서 2.2% BD-rate 이득과 주관적 화질 개선을 보인다.

  • PDF

The Multiple V-Y Advancement Modification for the Surgical Correction of Cryptotia

  • Nguyen Quang Duc;Nguyen Phuong Tien
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.26-29
    • /
    • 2023
  • Cryptotia is a rare congenital auricular deformity among Caucasians but more common in Asians. Various operative techniques have been described, such as skin graft, V-Y plasty, Z plasty, and islands skin flap. Among those techniques, V-Y plasty has many advantages and is indicated for severe cases. However, several problems remain when this method is adopted, such as conspicuous scars and lowered hairline. To overcome these problems, the authors have developed a new technique, multiple V-Y advancement modification, which stitches the skin flaps together to a tight, discrete central focal point. This technique has the advantage of hiding scars behind the earlobe, providing enough skin for the deformed areas, minimizing the condition of the hairline being lowered and auriculocephalic sulcus depth.

Measurement and Analysis of Bed Shear Stresses in Compound Open Channels using the Preston Tube (프레스톤튜브를 이용한 복단면 하도의 하상전단응력 측정 및 분석)

  • Lee, Du Han;Kim, Myounghwan;Kim, Won;Seo, Il Won
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.207-215
    • /
    • 2017
  • Hydraulic issues such as flow resistance, side wall correction, sediment, erosion and deposition, and channel design have close relation with distribution of bed shear stresses but the measurement of the distribution of bed shear stresses is not easy. In this study the Preston tube which makes possible relatively simple measurement of bed shear stresses is used to analyze the characteristics of bed shear distribution in compound open channels with different depth ratio. The Preston tubes are made and calibrated to develop the calibration formula and then they are applied to measure bed shear stress distribution in 5 cases depth ratio condition of compound channels. The results are compared with former experiment data, and characteristics of bed shear stress distributions are studied with different channel scales and Reynolds numbers. Although bed shear distributions with depth ratio show overall agreement with former studies, some differences are verified in bed shear variation, formation of inflection point in main channel, and distribution near floodplain junction which are due to high Reynolds number. Through the study applicability of the Preston tubes are also verified and characteristics of bed shear distribution in compound channels are suggested with Reynolds number and depth ratio.

Variation of Nanoindentation Curve due to Wear of Indenter Apex and Its Correction Method (압입자 첨단마모에 따른 나노압입곡선의 변화 및 이의 보정기법)

  • Lee, Yun-Hee;Kim, Yong-Il;Park, Jong Seo;Kim, Kwang Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.129-137
    • /
    • 2013
  • A force calibration of a nanoindenter and a 3D morphology observation of indenters were carried out in this study. A microbalance calibrated with standard weights was used for measuring the loads generated by a nanoindenter. The indentation load could be calibrated from the ratio of measured and generated loads and the first contact load also could be detected from the microbalance data. By analyzing atomic force microscopy images of two indenters, curvature radii of apexes were determined by $19.71{\pm}3.03$ and $1043.94{\pm}50.91$ nm, respectively, for the nearly new indenter A and the severly worn indenter B. Corresponding bluntness depths were estimated by 1.22 and 64.56 nm for the both indenters by overlapping their profiles on the perfect pyramidal shape. In addition, nanoindentation curves obtained from a fused silica reference material with the both indenters showed a depth difference corresponding to the bluntness depth difference along the indentation depth axis. By shifting amounts of the bluntness depths along the horizontal axis, whole nanoindentation curves overlapped on themselves and resulted in nanohardness values consistent within 1.11 % without considering the complex indenter area function of each indenter.

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

The Methodic Study on a Standard of Classification of Pulse Condition -a Focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$- (맥상 분류 기준에 대한 방법론적 고찰 - "빈호맥학(瀕湖脈學)"을 중심으로 -)

  • Lee, Ju-Ho;Choi, Hwan-Soo;Kim, Chul-Jung
    • Korean Journal of Oriental Medicine
    • /
    • v.10 no.1
    • /
    • pp.49-61
    • /
    • 2004
  • The Standardization of terms in The Pulse studies(脈學) is a need for development of learning. This study, for the correction of existing misused terms in The Pulse studies, we study on modernly and objectively the terms in The Pulse studies. By a focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$, we studies on the new classification of pulse condition. The error of a existing technical books on Pulse studies begin that the classification of pulse condition is not establish a Standardization. For the correction of existing misused terms in The Pulse studies, we study on the pulse condition is expressed objectively a blood vessel that it is a subject of pulse condition. The expression of blood vessel contain a depth of blood vessel, a speed of pulsation, a curve of blood vessel, thickness of blood vessel, a diameter of blood vessel in expand and contract of blood vessel, a interval in expand and contract of blood vessel, a distinctness on a boundary of blood vessel, a speed of blood flow in blood vessel, a volume of blood flow in blood vessel, a condition of blood in blood vessel, a propelling power of blood vessel. These is standard of the new classification of pulse condition.

  • PDF

Analysis of the O-Ring Deformation Behavior by the Computed Tomography (전산화 단층촬영에 의한 오링 변형 거동 분석)

  • Kim, Dong-Ryun;Kim, Jae-Hoon;Park, Sung-Han;Lee, Hwan-Gyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The object of this study is to develop the examination technique for measuring the O-ring deformation behavior under the pressure and the squeezed condition simultaneously. The O-ring deformation measuring device in which two grooves were dug to insert the two O-rings was manufactured to be not deformed under the high pressure and the 1 mm and 0.1 mm gap were designed to measure the extrusion lengths under the internal pressure. The beam hardening correction, the histogram analysis and the dead zone correction were executed to exactly measure the shape of O-ring deformation and the lengths of the O-ring deformation were measured by the LSF and the ERF. The computed tomography applied the pressure of 0, 1.378, 4.902, 9.804, 15.692 MPa at 22.3% squeezed condition and the expanded diameter, contact length and extrusion depth were measured in each pressure. The shape of O-ring deformation was evaluated by the FEM to verify the results of measuring by the computed tomography and the area of O-ring was mutually compared to the area measured by the computed tomography.