• 제목/요약/키워드: Dept. of dental technology

검색결과 523건 처리시간 0.02초

20대 여성 정상교합자에서 임상치관의 순·설측 경사도와 근·원심 경사도에 관한 연구 (A Study on Clinical Crown Angulation and Inclination of Females in the Twenties with Normal Occlusion)

  • 조홍규
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.415-424
    • /
    • 2013
  • Purpose: This study is to present a standard value for clinical crown angulation and inclination required in laboratory process and see if the value can be used for actual laboratory process. Methods: In order to find out a standard value for clinical crown angulation and inclination, this study made a study model of normal occlusion of 21 females in twenties. The clinical crown angulation and inclination of both six-maxillary and six-mandibular anterior teeth are measured by Set-up Model Checker. From the measured value above, the mean and standard deviation of the twelve teeth are obtained, and then the mean of the teeth between right and left side is calculated. Results: Each clinical crown angulation of maxillary central incisor, lateral incisor, and canine is like this; $1.0^{\circ}{\pm}1.3^{\circ}$, $3.0^{\circ}{\pm}1.3^{\circ}$, and $5.0^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.6^{\circ}{\pm}1.1^{\circ}$, $1.5^{\circ}{\pm}1.1^{\circ}$, and $4.1^{\circ}{\pm}1.1^{\circ}$. Each clinical crown inclination of maxillary central incisor, lateral incisor, and canine is like this; $6.1^{\circ}{\pm}1.8^{\circ}$, $4.5^{\circ}{\pm}1.9^{\circ}$, and $-6.2^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.3^{\circ}{\pm}1.5^{\circ}$, $0.3^{\circ}{\pm}1.8^{\circ}$, and $-7.5^{\circ}{\pm}1.8^{\circ}$. Conclusion: As the result, the mean value for clinical crown angulation and inclination can be referred to actual laboratory process. However, the mean value is different from those of the precedent study and an unsatisfied one for adopting the standard value.

Ti-Nb계 합금의 상변화가 기계적 성질에 미치는 영향 (Effects of phase changes on mechanical properties of Ti-Nb alloys)

  • 박효병
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.9-17
    • /
    • 2005
  • The use of titanium alloys as biomaterials is increasing due to their superior biocompatibility and enhanced corrosion resistance compared to conventional stainless steels and cobalt-based alloys. Ti-6Al-4V ($\alpha+\beta$type) alloy instead of pure titanium ($\alpha$type) is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. But it has been reported recently that the vanadium element expresses cytotoxicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. In order to overcome their detrimental effects, $\beta$-phase stabilizer Nb was chosen in the present study. This paper was described the influence of phase changes of Ti-Nb alloys on mechanical properties. Ti-3wt.%Nb($\alpha$type),Ti-20wt.%Nb($\alpha+\beta$type) and Ti-40wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. The specimens were homogenized at 1050$^{\circ}C$ for 24hr and were then hot rolled to 50% reduction. Each alloys were solution heat treated at $\beta$ zone and $\alpha+\beta$ zone after homogenization and then were aged. The mechanical properties of Ti alloys were analysed by hardness test, tensile test, elongation test and SEM test. The results can be summarized as follows: 1) The higher hardness value of $\alpha+\beta$type alloy was obtained compared to the, $\alpha,\beta$type alloys. 2) The aged treated showed better hardness compared to the solution heat treated, homogenized. 3) In the case of solution and aging treatment at $\beta$region, the $\alpha+\beta$type alloy showed the most highest tensile strength and $\beta$type alloy showed the best elongation.

  • PDF

어트리션 밀링법으로 제조된 티타늄합금의 상변화 및 미세조직특성 (Phase Changes and Microstructural Properties of Ti Alloy Powders Produced by using Attrition Milling Method)

  • 차성수
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.9-19
    • /
    • 2001
  • Microstructure and phase transformation of Ti-Ni-Cu alloy powders produced by using attrition milling method were studied. Mixed powders of Ti-(50-X)Ni-XCu ($X=0{\sim}20$ at%) in composition range were mechanically alloyed for maximum 20 hours by using SUS 1/4" ball in argon atmosphere. Ball to powder ratio was 50: 1 and impeller speed was 350rpm. Mechanically alloyed with attrition millimg method. powder was heat treated at the temperature up to $850^{\circ}C$ for 1 hour in the $10^{-6}$ torr vacuum. Ti-Ni-Cu alloy powders have been fabricated by attrition milling method. and then phase transformation behaviours and microstructual properties of the alloy powders were investigated to assist in improving the the high damping capacity of Ti-Ni-Cu shape memory alloy powders. The results obtained are as follows: 1. After heat treating of fully mechanically alloyed powder at $850^{\circ}C$ for 1hour. most of the B2 and B 19' phases was formed and $TiNi_3$ were coexisted. 2. The B 19' martensite were formed in Ti-Ni-Cu alloy powders whose Cu-content is less than 5a/o. where as the B19 martensite in those whose Cu-content is more than 10at%. 3. The powders of as-milled Ti-Ni-Cu alloys whose Cu-contents is less than 5at% are amorphous. whereas those of as-milled Ti-Ni-Cu alloys whose Cu-content is more than 10at% are crystalline. This means that Cu addition tends to suppress amorphization of Ti-Ni alloy powders.

  • PDF

수종의 색소체용액으로 제작된 유색 지르코니아의 색조비교 (The color comparison of zirconia fabricated by using various coloring liquids)

  • 오계정;정종현
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.247-253
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate the effect of colored zirconia with different coloring liquids. Methods: Total 30 specimens were prepared. Specimens were classified into 6 groups: IPS e.max Ceram(P), Uncolored zirconia(C), VITA In-Ceram$^{(R)}$2000 YZ LL1(L), Zirkonzahn coloring liquid(Z), Wieland coloring liquid(W), and Kuwotech coloring liquid(K). Four different types of zirconia coloring liquid, VITA In-Ceram$^{(R)}$ 2000 YZ LL1(VITA Zahnfabrik, Germany), Zirkonzahn coloring liquid(Zirkonzahn, Italy), Wieland coloring liquid(Wieland, Germany), Kuwotech coloring liquid(Kuwotech, Korea) were used to fabricate colored zirconia by using infiltrating method and then completely sintered. The color of the all specimens was measured using the spectrophotometer(CM-2600d, Konica Minolta, Japan) and expressed in terms of the 3-coordinated values(CIE $L^*a^*b^*$). Color differences were calculated using the equation $${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{1/2}$$. Results: $L^*a^*b^*$ values of the colored zirconia were affected by the coloring liquids. The uncolored zirconia(C) group showed the highest $L^*$ value and zirkonzahn coloring liquid(Z) group showed the lowest $L^*$ value. Zirkonzahn coloring liquid(Z) showed the highest $a^*$ value and VITA In-Ceram 2000 YZ LL1(L) group showed the highest $b^*$ value. Generally, the color difference(${\Delta}E^*$) in all groups showed higher than 3.7 except between IPS e.max Ceram(P) and wieland coloring liquid(W) group. Conclusion: Within the limitations of this study, various coloring liquids influenced the $L^*$, $a^*$, and $b^*$ values of colored zirconia. IPS e.max Ceram(P) and wieland coloring liquid(W) group did not show clinically perceiving color difference.

일부 치위생학과 학생들의 행복지수에 미치는 영향요인 (Factors Affecting Dental Hygiene Students' Happiness Index)

  • 성정희;유수민;최길복
    • 문화기술의 융합
    • /
    • 제4권4호
    • /
    • pp.181-186
    • /
    • 2018
  • 다양한 이유로 치위생과에 입학한 학생들 중 국가고시에 대한 스트레스와 학교생활에 어려움을 가지고 있는 학생들의 스트레스 해소와 만족스러운 학과생활을 위한 상담 및 교육 프로그램의 개발의 기초자료를 제공하고자 충청, 경상지역의 213명의 치위생(학)과 재학생들을 대상으로 설문조사를 실행하였다. SPSS 3.0으로 분석한 결과 행복지수는 21점 만점에 평균 16.32점으로 만족감이 15.17점으로 가장 높았으며, 긍정정서가 13.79점, 부정정서가 12,64점으로 나타났으며, 성별, 성격, 친구관계, 학업성취도, 용돈 만족도, 건강상태에서 통계적으로 유의한 차이를 보였다. 전공만족도에서는 성격, 친구관계, 진학동기, 전강상태에서 통계적으로 유의한 차이를 나타냈고, 행복지수와 전공만족도는 통계적으로 유의한 상관관계를 갖는 것으로 나타났다.

지르코니아와 전장용 세라믹의 색상에 관한 연구 (A Study on the Colors of Zirconia and Veneering Ceramics)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.129-134
    • /
    • 2012
  • Purpose: This study was conducted to investigate the colors of zirconia and veneered ceramics according to the build-up method of veneer porcelain. Methods: The samples were divided into three groups: a group for which a liner was applied to the zirconia surface and dentine coating was built up and burned (Cz1), a group for which the dentine coating was directly built up and burned (Cz2), and a group for which the samples were wash-burned with dentine coating and a dentine coating was built up and burned again (Cz3). The the colors were measured with a Spectrophoto-meter. Results: The average $L^*$ value of the Cz3 group was the highest among the groups at $59.1{\pm}0.5$ (P<0.05), followed by Cz2 at $57.5{\pm}0.8$ and Cz1 at $56.6{\pm}1.3$. The $a^*$ value of Cz3 was negative at $-0.0{\pm}0.0$ and the $a^*$ values of Cz2 and Cz1 were positive at $0.2{\pm}0.1$ and $0.4{\pm}0.0$, respectively (P<0.05). The $b^*$ of Cz1 was the highest at $11.2{\pm}0.6$, followed by Cz3 at $10.8{\pm}0.5$ and Cz2 at $10.5{\pm}0.8$ (P<0.05). Conclusion: Compared to other experimental groups, the Cz3 groups showed the brightest colors with high brightness and relatively low green and yellow levels.

안구운동 프로그램 적용이 노인의 정적 균형에 미치는 영향 (The Influence of Eye Movement Program Applied to Elderly People on Static Balance)

  • 박종항;강보람;김윤환;김장주;손경현;송현승;김태원
    • 대한정형도수물리치료학회지
    • /
    • 제17권2호
    • /
    • pp.11-17
    • /
    • 2011
  • Background: To evaluate the influences of Eye movement program applied to elderly people on static balance. Methods: The subjects consisted of fourteen elderly people. The subjects were divided into two group. The control group (n=7) received no exercise and/or stimulation. The Eye movement program training (E/P) group (n=7) performed balance training using word card and batom. E/P group were accomplished during 4weeks (5 day/week, 60 min/day). All tests were completed before and after experiment. The static balance ability was measured by normal standing when eye open and close on good balance system, respectively. For each case, the experimental data were obtained in 3 item; mean X speed, mean Y speed and velocity moment. Results: The result of this study were as follows: 1. In E/P group, the statistically significants were shown on only mean Y speed in the case of normal standing when eye open (p<.05), but the statistically significants were not shown on mean X, Y speed and velocity moment in the case of normal standing when eye close (p>.05). 2. In control group, the statistically significants were not shown on all posture (p>.05). 3. There was a statistically significant difference on the mean Y speed and velocity moment in the case of normal standing when eye open between control group and E/P group (p<.05). Conclusions: The above results revealed that balance training using Eye movement program were partly effective for improving the static balance ability.

  • PDF

치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구 (The Study on the Protection and Actual Condition of Using the Dental X-ray Unit)

  • 강은주;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF

Ag-30wt% Pd-10wt% Cu 3원합금(元合金) 및 Au 첨가합금(添加合金)의 시효경화특성(時效硬化特性) (The Effect of Au Addition on the Hardening Mechanism in Ag-30wt%Pd-10wt%Cu Alloy)

  • 이기대;남상용
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.27-41
    • /
    • 1999
  • 치과용 Ag기 합금에서 30wt%Pd 및 10wt%Cu의 용질농도의 구성비가 3이 되는 3원 합금과 여기에 2wt% Au의 첨가에 미치는 석출상의 영향을 조사 분석하여 아래와 같은 결론을 얻었다. Ag-Pd-Cu 3원 합금은 $\alpha$ 단일상에서 Ag-rich ${\alpha}_2 $ 및 PdCu 규칙상에 의해서 경화반응이 진행되며 연속승온시효곡선에 의하면 100-$300^{\circ}C$의 저항증가와 300-$500^{\circ}C$의 저항감소라고 하는 2단계 변화에 의해서 경화곡선이 얻어졌다. 또한 본 합금의 시효과정에서는 ${\alpha}{\to}{\alpha}_2+PdCu{\to}$의 2상 분리반응에 의하여 경화원인이 되었다. 석출과정은 ${\alpha}{\to}{\alpha}_1+PdCu{\to}{\alpha}_2+PdCu$ 이고 Cu-rich인 ${\alpha}_2$상은 거의 나타나지 않으며 최고 경도값은 ${\alpha}_2$ 및 PdCu의 2상공존 구역에서 나타났다. 미량의 Au첨가에 의해서 경화는 다소 증가하지만 경화성보다는 내식성에 보다 크게 기여하였고 Pd/Cu=3인 합금은 Pd/Cu=1 또는 1.7의 합금보다도 전반적으로 경도값은 가장 낮게 나타나며 이것은 치과용 Ag기 합금의 시효경화성에는 Cu농도가 크게 기여하였다. 불연속석출물인 nodule 생성물은 입계에 우선 형성되어 $\alpha$ matrix로 진행되어 nodule 석출물은 부드러운 경계면을 가지고 $\alpha$ matrix주위에 strain matrix를 나타내므로 nodule 형성이 본 합금의 시효경화를 야기하였다. 내식성은 Pd 함량이 가장 높은 본 합금에서 매우 양호하게 나타났으며 Pd 함량이 증가가 내식성의 향상에 크게 기여하여 미량의 Au 첨가에 의해서 보다 현저히 효과를 얻었다. 본 합금의 시효열처리 조건은 $450^{\circ}C$ 적절하며 1-120min 시효시간에 걸쳐서 소정의 경도 값을 얻을 수 있고 시효경화성 및 내식성의 결과로부터 Ag-30wt%Pd-10wt%Cu합금 및 미량 Au 합금은 치과용 금속재료로 적합하였다.

  • PDF

도재용착주조관용 Ni-Cr 합금의 반복주조가 부식거동에 미치는 영향 (The Effect of Recasting on the Corrosion behavior of Ni-Cr alloy for Porcelain Fused to Metal Crown)

  • 배수현;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.355-366
    • /
    • 2006
  • The purpose of this study was to determine if repeated casting has a detrimental effect on the corrosion behavior of nickel-chrome casting alloys. The X-ray diffraction analysis, vickers hardness test, SEM, EDX and corrosion test were performed to determine the effects of recasting on chemical composition, microstructure, physical property, castability and corrosion behavior of nickel-chrome casting alloys. The X-ray diffraction analysis results for the cast and recast specimens of the VeraBond and the Rexillium V showed that major crystal phase contained nickel-chrome compounds, Nickel carbide and Chrome carbide. Microstructure analysis results for the cast and recast specimens of the VeraBond and the Rexillium V showed recasting has no effect on microstructure. EDX analysis results indicated the percentage of the main component nickel(Ni) in the specimens of the VeraBond showed a tendency to increase with recasting, but those of other components Carbon(C) showed a tendency to decrease with recasting, Chrome(Cr), Silicon(Si), Aluminium(Al) and molybdenum(Mo) showed no changes in the percentage. The percentage of the main component nickel(Ni) in the specimens of the Rexillium V showed a tendency to increase with recasting, but those of other components silicon(Si), carbon(C) and molybdenum(Mo) showed a tendency to decrease with recasting, chrome(Cr) and aluminium(Al) showed no changes in the percentage. The vickers hardness results for the cast and recast specimens of the VeraBond and the Rexillium V showed a tendency to decrease with recasting, but the differences for the first to fifth cast were not statistically significant. The castability results for the cast and recast specimens of the VeraBond and the Rexillium V showed a tendency to decrease with recasting, but the differences for the first to fifth cast were not statistically significant. The cast and recast specimens of the VeraBond and the Rexillium V showed no differences in the corrosion resistance. The results indicate that the VeraBond and the Rexillium V can be safely recast.

  • PDF