• Title/Summary/Keyword: Dept. of dental technology

검색결과 523건 처리시간 0.083초

A study on reflective spectrum between In-Ceram alumina core and IPS Empress 2 core (In-Ceram Alumina Core와 IPS Empress 2 core의 분광반사율 연구)

  • Park, Myung-Ja;Kim, Joo-Won
    • Journal of Technologic Dentistry
    • /
    • 제23권2호
    • /
    • pp.189-202
    • /
    • 2002
  • A study on reflective spectrum between In-Ceram alumina plate(IAP) and IPS empress 2 plate were carried out in order to determine the difference of reflective spectrum rates between materials and between thicknesses of materials(0.8mm, 1.0mm, 1.2mm) by visible wave. The rates are measured by spectrophotometer(Top scan model TC-1800). And an analysis of ANOVA and paired sample t-test were carried out. The results are summarized as follows. 1. The reflective rates of IAP and IPS increased slowly as visible wave spectrum increased. 2. The difference of reflective rates of IAP between 0.8mm and 1.0mm is significant but a little(less than 1%). The differences of reflective rates of IAP between 0.8mm and l.2mm and between 1.0mm and l.2mm are significant(8%, 10% ). 3. The differences of reflective rates of IPS between 0.8mm and 1.0mm and between 0.8mm and 1.2mm and between 1.0mm and 1.2mm are significant(0.06 %, 0.01 %, 2 %). 4. The differences of reflective rates of 0.8mm, 1.0mm between IAP and IPS are significant but a little(less than 0.9%, 0.5%). The difference of reflective rates of l.2mm between IAP and IPS is significant and larger than the other thicknesses relatively(7 %).

  • PDF

A Study on the Castability of Investing Method and Casting Direction of Chrome-Cobalt Alloy Widely Used in Production of Patial Denture Framework (국부의치 제작에 사용되는 Chrome Cobalt Alloy 주조 시 매몰방법과 주조방향이 주조성에 미치는 영향에 관한 연구)

  • Chung, Kyung-Pung;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • 제21권1호
    • /
    • pp.77-85
    • /
    • 1999
  • When producing partial denture using a Chrome-cobalt alloy being used universally, 45 pattern of them to compare casting characters according to 5 burying methods(special ring method, plastic ring method, general metal ring method) and 5 casting directions(straight, upper, lower, left and right directions) were compared and evaluated. The results were as follows : 1. The comparison of casting characters in accordance with burying type shows that the special ring method to install blind air vent using utility wax was the highest rate of 76.9%, followed by 69.1% of the plastic ring to cast without ring and 61.1% of the metal ring method being used universally respectively. Namely the special ring method was best. The significant level was P<0.05 statistically. 2. The comparison of casting character in accordance with casting directions shows that the straight casting was the highest of 77.9%, and followed by right casting of 74.2%, left casting of 66.7%, upper casting of 63.5%, and lower casting of 62.9% respectively, Namely the straight casting was best.

  • PDF

The Comparative Study on the Castability to the Frequency of Reuse with Precious Metal Alloys and Base Metal Alloys widely used in the Production of Partial Denture (국부의치(局部義齒) 제작(製作)에 사용(使用)되는 귀금속합금(貴金屬合金)과 비귀금속합금(非貴金屬合金)의 재(再) 사용(使用) 횟수에 따른 주조성(鑄造性) 비교(比較) 연구(硏究))

  • Chung, Kyung-Pung;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • 제17권1호
    • /
    • pp.10-25
    • /
    • 1995
  • The purpose of this study is to get the difference of the castability in the production of partial denture between Precious Metal Alloys and Base Metal Alloys accompanied with the frequency of reuse. As materials for an experiment, we selected Baker-444 and Soo-444 and Soo-sung as Precious Metal Alloys, New Crown and Chrome Cobalt as Base Metal Alloys. And we tired to case all of them seven times. The experimental results were as follows : 1) In the probability of segments, Baker-444 showed 100$\pm$0.00%, Soo-sung 97.24$\pm$1.58%, New Crown 95.63$\pm$4.28%, and Chrome Cobalt 91.03$\pm$7.76%. Consequently, Precious Metal Alloys were decidely superior to Base Metal Alloys in the castability. 2) In the view of the acheived result, burn-out temperature and smocking time had greatly affected the castability. 3) After casting, Precious Metal Alloys were much less than Base Metal Alloys in the quantity of consumption. It made much difference from the the compiled stastics(p<0.01)

  • PDF

Evaluation of Corrosion Resistance of Ti-Zr-Nb-Pd Based Alloys for Biomedical applications by electron Theory (전자론에 의한 생체용 Ti-Zr-Nb-Pd계 합금의 내식성 평가)

  • Jung, Jong-Hyun;Sun, Gum-Ju
    • Journal of Technologic Dentistry
    • /
    • 제26권1호
    • /
    • pp.35-40
    • /
    • 2004
  • In order to understand alloying effects on the corrosion resistance of Ti-(10$\sim$20)%Zr-(2$\sim$8%)Nb-0.2%Pd alloys, Polarization curves were measured at 5%HCI solution. The results were interpreted in terms of two parameters obtained by the molecular orbital calculation ; one is the bond order($B_{\circ}$) and the other is the metal d-orbital level($M_{d}$). $B_{\circ}$ is a measure of the strength of covalent bonds between titanium and alloying elements. $M_{d}$ is correlative with the electronegativity of elements. It was found that increasing of Zr and Nb with higher $B_{\circ}$ values showed a lower critical anodic current density in the polarization curve and hence higher corrosion resistance. On the other hand, increasing of Zr and Nb with higher $M_{d}$ values showed a higher corrosion resistance.

  • PDF

A Comparative Analysis about Curriculum of The Domestic and Foreign Dental Laboratory Technology (해외와 국내의 치과기공 교육과정 비교분석)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • 제31권4호
    • /
    • pp.67-84
    • /
    • 2009
  • The purpose of this study was to furnish data for a new curriculum of the "Bachelor's Degree Course at Junior College" in Korea. Domestic three colleges and one university were selected for comparative analysis about curriculum of the dental laboratory technology. Moreover, three colleges and three universities were selected in Australia, Canada, and USA which are preferred highly on overseas employment by the korea students of dental laboratory technology. From the six colleges and four universities, number of subjects and credit hours on special study were acquired and compared. Between domestics, an agreement on special study were compared. Transferable subjects from korea to foreign were acquired. From the number of subjects and credit hours on special study comparing, following results were obtained. The results were as follows; 1. The ratio of the number of subjects and credit hours on special study were averagely 78.2% and 83.7% in domestic college, 70.8% and 69.7% in domestic university. 2. The ratio of the number of subjects and credit hours on special study in Canada was similar to domestic but those in Australia and USA were less than domestic. 3. Between domestics, an agreement of subjects and credit hours on special study were 81.2% and 84.2% in Catholic University of Busan, 72.2% and 76.4% in Daejeon Health Science College, 71.2% and 72.8% in Gwangju Health College University, 65.1% and 65.9% in Shin Heung College University respectively. 4. Transferable subjects from Korea to Australia or Canada was more than USA. Those to Australia was similar to Canada. These results suggest that the degree of special study in domestic is more than foreign, transferable subjects from Korea to Canada should be profitable and those data is furnish for a new curriculum of the "Bachelor's Degree Course at Junior College" in Korea.

  • PDF

The flow change of the inlay waxes at various temperatures (온도변화에 따른 인레이 왁스의 유동성 변화)

  • Nam, Sang-Yong;Lee, Duk-Su
    • Journal of Technologic Dentistry
    • /
    • 제28권2호
    • /
    • pp.367-373
    • /
    • 2006
  • This study was performed to observe the flow change of the inlay waxes at various temperatures. The flow of inlay waxes was tested according to the treatment conditions, for 10 minutes at 40$^{\circ}C$, 41$^{\circ}C$, 42$^{\circ}C$, 43$^{\circ}C$, 44$^{\circ}C$, and 45$^{\circ}C$ The flow of inlay waxes at various temperatures was measured with an electro dial gauge. The results were as fellows: 1. The flow change of the inlay waxes at various temperatures was shown to increase in the order of wax A, B, D, C. 2. Wax A was close to ADA specification with 3% flow at 40$^{\circ}C$ and 71% flow at 45$^{\circ}C$, but wax B and D did not reach up to ADA specification with 40% flow at 45$^{\circ}C$. 3. Wax C came up with 3% flow at 40$^{\circ}C$ and 7% flow at 45$^{\circ}C$, and it revealed a very low flow change at 5$^{\circ}C$.

  • PDF

The Effect of Oxidation Heat Treatment on Porcelain to Metal Bond Strength (도재용착주조관용 비귀금속 합금의 사전 열처리가 도재-금속의 결합 강도에 미치는 효과)

  • Kim, C.Y.;Nam, S.Y.
    • Journal of Technologic Dentistry
    • /
    • 제19권1호
    • /
    • pp.37-42
    • /
    • 1997
  • The interfacial bond strengh and microstructural analysis of pre-heat treated porcelain-fusedmetal(PFM) were investigated using a mechanical three-point bending tester and scanning electron microscope(SEM). Four kinds of heat treated samples were prepared as follows ; A: Heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating ${\to}1850^{\circ}F$, hold 3min under vacuum, B: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$ under vacuum conditon, C: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 3min in the air, repeat same heat treatment process under vacuum condition, D: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 1min in the air. The three-point bening test result shows that the interfacial bond strength of specimen B and C were higher than that of A and D. The SEM study indicate that Specimen C shows the highest surface density.

  • PDF

A Study on the Usage of Dental Serveyor(I) (Dental Serveyor의 사용법에 관한 연구(I))

  • Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • 제15권1호
    • /
    • pp.63-72
    • /
    • 1993
  • The following results were come out after the careful study on the rational application of dental surveyor in the clinic 1. The adequate path of placement satisfying guiding plane, retention non-interference and esthetics. 2. The location of clasp arm and the accurate under cut position and amount of clasp tip can be judged. 3. In case that the model needs to be mounted to the surveyor, the exactly same location can be attained by the means of the tripoding. 4. The unnecessary undercut areas in the path of placement and removal car be corrected. 5. The surveyor is essential in manufacturing dental prosthesis and it can also carry out all sorts of prospective designs In terms of the diagnosis and treatment.

  • PDF

Development of an Accident Prevention Education Program on an application of the Theory of Planned Behavior during Exercise (Focusing on Students Majoring in Dental Technicians) (계획된 행위이론을 적용한 실습중 사고예방 교육 프로그램 개발 - 치기공학과 학생을 중심으로 -)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • 제33권1호
    • /
    • pp.65-77
    • /
    • 2011
  • Purpose: The purposes of this study were to provide information about safe actions during the practice of dental technology, promote belief in safe actions among the students of dental technology, and reinforce their knowledge about how to act safety. Methods: Open questions were asked to 120 sophomores majoring dental technology to understand the target group's belief about safe actions. Following the instructions by Ajzen & Fishbein, the collected data were grouped according to similar beliefs. Those beliefs of the highest frequency were given a priority and got to represent the belief level of the target group. Even with belief changes, however, they would not be able to practice safe actions if they had no knowledge about how to do safe actions. For desirable behavioral changes among the students, the students were then asked to discuss the current state of safety accidents and issues focusing on the materials and processes used in the practice and give presentations regarding the subjects to identify risk factors. Then the identified risk factors were used to devise the program contents so that the students could practice safe actions through accurate behavioral approaches and belief changes by educating them about how to act safely by the practice processes and the involved materials and devices. Results: Not only do the students of Dept. of Dental Technicians have difficulties with the complex practice processes while practicing to make dental prosthesis, but they are exposed to the risk of accidents as they're poor at dealing with the materials and devices. Although there is a definite need for accident prevention education programs before practice, the reality is that the school doesn't the schoosuch education. Based on the judgment that an education program designed to reinforce belief for behavioral changes would generate effgrams results, an education program was developed by applying the Theory of Planned Behavior(TPB). Along with their beliefs, the current state of accidents n. Basepractice, demand for safety education, and practice level of safe actions were used to device the contents of accident prevention education and to develop an accident prevention education program for dental technology. Conclusion: The study presents an accident prevention education program developed to reinforce dental technology students' beliefs and knowledge and to help them do safe actions during practice.

A Comparative Analysis of Stress Distribution in the Implant Supporting Bone by Occlusal Loading location Utilizing the Finite Element Method (유한요소법을 이용한 교합 하중 위치에 따른 임플란트 지지골의 응력분포 비교분석)

  • Lee, Myung-Kon;Kim, Young-Jick;Kim, Chi-Young
    • Journal of Technologic Dentistry
    • /
    • 제27권1호
    • /
    • pp.105-113
    • /
    • 2005
  • The purpose of this study is to evaluate the effect of loading at three different occlusal surface position of the gold alloy crown on the stress distributions in surrounding bone, utilizing 3-dimensional finite element method. A three dimensional finite element model of an implant with simplified gold alloy crown and supporting bone was developed for this study. A oblique or vertical load of 100 N was applied at the following position at each FE model : 1) center of occlusal surface, 2) a point on the buccal side away from center of occlusal surface (COS) by 2.8mm, 3) a point on the lingual side away from COS by 2.8mm. In the results, Minimum von Mises stresses under vertical load or oblique load of 100N were about 6MPa at the center of occlusal surface and about 40MPa at the point on the buccal side, respectively. From the results we could come to the conclusion that occlusive loading position could be an important factor for establishment of structural safety of supporting bone.

  • PDF