• 제목/요약/키워드: Department of Radiologic Science

검색결과 349건 처리시간 0.035초

방사선 이용의 필요성 및 인체장해에 대한 대학생의 인식조사 (An Investigation on The Necessity of the Use of Radiation and The Recognition of Radiation Hazard among College Students)

  • 한은옥;문인옥
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제7권
    • /
    • pp.51-58
    • /
    • 2006
  • Background & Objectives: This study investigates the recognition on the necessity of the use of radiation for both college students who are considered that they have a high knowledge level in radiation and proposes basic materials to change the recognition of the use of radiation. Also, the investigation was applied to average people who showed the most negative attitudes on radiation. Methods: A questionnaire was applied to 600 college students for five days from October 10 to 15, 2005 and used in statistical analysis. Results: The average value obtained in the recognition of the use of radiation was 76.60 points in which male respondents who were majored in natural science, health, and engineering department and respondents who have experienced radiation related education, radiation diagnosis, and radiation treatment demonstrated higher levels. Also, the average value obtained in the recognition of the radiation damage was 71.66 points in which respondents who were majored in natural sciences, humanities, engineering, and health department showed higher levels than that of respondents who were majored in art and physical department. Groups that exhibited higher recognition levels in the necessity of the use of radiation were male respondents and respondents who were majored in natural science, humanities, and health department and have experienced radiation diagnosis and radiation treatment. In the results of the correlation analysis on the necessity of the use of radiation and recognition of radiation damages, the recognition of radiation damages was presented as negative attitudes in the case of the higher recognition level in the necessity of the use of radiation. Conclusions: Regarding the frequency of the use of radiation in Korea, a 80.9% of university students who showed a high education level had no experiences in radiation related education. Although they showed a relatively high level of 76.6 points in the recognition level of the necessity of the use of radiation, the negative attitude on the radiation damage was also presented as a high level of 71.7 points. Because the providing chance of radiation related information was limited as compared to the atomic power used in Korea and dependancy of the use of radiation, it is necessary to provide the basic information related in the use of radiation to the public. In addition, various investigations on the use of radiation and such negative attitudes are required in future for the public. Also, the correct information of the radiation safety should be delivered to the public.

  • PDF

MDCT 검사에서 환자 체중을 이용한 선량 평가 (Estimate of Radiation Doses in MDCT Using Patient Weight)

  • 권성욱;동경래;권대철;구은회;최지원;정운관
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.246-252
    • /
    • 2010
  • 환자가 두부, 흉부, 복부 MDCT 검사에서 피폭되는 선량을 평가하였다. 선량의 지표는 CTDIvol, DLP, 유효선량을 평가하여 환자의 체중과 선량과의 상관관계를 분석하였다. CT 검사에서 검사 조건을 동일하게 하여 연속적으로 두부(520명), 흉부(531명), 복부(724명) 환자를 대상으로 하였다. CTDIvol과 DLP 평균선량은 두부검사에서 CTDIvol (48.6 mGy), DLP (1,604 $mGy{\cdot}cm$), 흉부검사에서 CTDIvol (6.9 mGy), DLP (250 $mGy{\cdot}cm$), 복부는 CTDIvol (10.5 mGy), DLP (575 $mGy{\cdot}cm$), 유효선량은 두부, 흉부, 복부에서 3.6, 4.2, 8.6 mSv로 분석되었다. 환자의 체중과 선량과의 상관분석에서 두부, 흉부, 복부에서, 두부는 상관관계가가 보이지 않았고, 흉부는 CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694), 복부는 CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741)와 양의 상관관계를 나타내냈다. 검사에 따른 체중과의 상관관계를 이해하고 검사 하면 방사선 피폭에 의한 선량을 평가하고 관리하는데 기여 할 수 있을 것이다.

영상의학과 촬영실의 미생물 분포에 관한 연구 (A Study on the Distribution of Microorganisms in Department of Radiography)

  • 장정현;양은주;김영재
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.165-171
    • /
    • 2021
  • 영상의학과의 일반방사선 촬영실의 2차 원내감염(교차감염)의 방지를 위해 방사선사, 환자와 직접적인 밀접접촉부분의 미생물을 측정하였다. 방사선사 측은 방사선 발생장치의 엑스선튜브 손잡이, 환자측은 턱받침대, 가슴닿는 곳, 손잡이를 중심으로 미생물을 측정하여 배양하였다. 에니오설프로 소독한 후 멸균배지를 이용해 수합하고 동정하여 미생물을 확인하였다. 동정결과 방사선사 측은 Proteus mirabilis, Staphylococc us epidermidis, Bacillus spp., Candida spp., 103CFU, 환자측은 Proteus mirabilis, Enterococcu faecium, Pseudom onas aeruginosa, NTM, Candida spp. 가 103~5 CFU 검출 되었으며 환자측에서 수합된 미생물의 종류와 수가 더 많이 관찰되었다. 다행히 해당되는 미생물은 대부분 피부표면에 있는 것들로 관찰되었으며 원내감염관리 규칙에 의거하여 소독한다면 대부분 사멸하는 것으로 알려져 있지만 면역력이 떨어진 환자의 경우 소량의 노출로도 치명적일 수 있으므로 주의해야 한다. 특히, 환자와 접촉한 부분의 미생물이 높게 측정된 것을 보아 방사선사 및 수시출입자 등은 환자와 접촉이 잦은 기구 및 손잡이 등의 부분에 대해 소독을 철저히 해야 할 것으로 사료된다. 기존 에니오설프 연구를 기반으로 현재연구를 확대하여 원내 방사선 검사실의 미생물 안전관리의 중요성을 알리는 목적으로 조사하였고 병원 2차 및 N차 감염병 예방을 위한 기본적인 자료가 될 수 있을 것이다.

비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가 (Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT)

  • 강동진;정재용;신영주;민정환;심재구;박소현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구 (Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention)

  • 김정수;권순무;정혜경;이봉기;류동열;권호석;조병렬
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.181-186
    • /
    • 2016
  • 심장혈관 조영술과 심장혈관 중재술은 심장혈관 질환을 치료하는 안전하고 효율적인 시술이다. 그러나 시술이 이루어지는 동안 환자와 시술자의 방사선 피폭에 대해서는 주의가 필요하다. 본 연구의 대상으로는 2015년 9월부터 2016년 1월 사이에 강원도 소재 한 대학병원의 심혈관센터에서 시행된 147명의 심장혈관 조영술(CA)과 심장혈관 중재술(CI)을 시행한 환자를 대상으로 시술자의 피폭선량을 평가하였다. CA만을 시행한 경우 시술자의 유효선량은 최소 0.39 uSv, 최대 30.6 uSv를 나타냈고 평균 유효선량은 4.11 uSv를 나타냈다. CI를 시행한 경우 유효선량은 최소 1.618 uSv, 최대 202.805 uSv를 나타냈고 평균 유효선량은 34.41 uSv를 나타냈다. 본 연구의 결과에서 갑상선 위치에서 측정된 선량을 머리가 받은 선량으로 대체할 경우 PCI에서 평균 받는 선량을 연평균 1000건의 시술을 시행한다고 할 경우 90 mSv/year 에 해당한다. 이를 2년 누적할 경우 눈의 제한선량인 150 mSv를 초과하는 수치이다. 심장혈관 중재적 시술은 의료 방사선의 피폭에 있어 CT 다음으로 큰 부분을 차지하고 있다. 따라서 시술이 시행되는 동안 환자와 시술자의 방사선 방어가 적절히 이루어질 수 있도록 하여야 하며 검사의 최적화와 정당성을 확보하여 안전한 검사가 될 수 있도록 해야 한다. 이를 위해 시술자에게는 적절한 교육이 이루어져야 하고 시술 중에는 개인방어 장비를 착용하여야 하며 모니터링을 통해 환자와 시술자의 피폭선량을 줄이는 노력이 필요하다.

Clinical Practice Guidelines for Gastric Cancer in Korea: An Evidence-Based Approach

  • Lee, Jun Haeng;Kim, Jae G.;Jung, Hye-Kyung;Kim, Jung Hoon;Jeong, Woo Kyoung;Jeon, Tae Joo;Kim, Joon Mee;Kim, Young Il;Ryu, Keun Won;Kong, Seong-Ho;Kim, Hyoung-Il;Jung, Hwoon-Yong;Kim, Yong Sik;Zang, Dae Young;Cho, Jae Yong;Park, Joon Oh;Lim, Do Hoon;Jung, Eun Sun;Ahn, Hyeong Sik;Kim, Hyun Jung
    • Journal of Gastric Cancer
    • /
    • 제14권2호
    • /
    • pp.87-104
    • /
    • 2014
  • Although gastric cancer is quite common in Korea, the treatment outcome is relatively favorable compared to those in western countries. However, there are currently no Korean multidisciplinary guidelines for gastric cancer. Experts from related societies developed guidelines de novo to meet Korean circumstances and requirements, including 23 recommendation statements for diagnosis (n=9) and treatment (n=14) based on relevant key questions. The quality of the evidence was rated according to the GRADE evidence evaluation framework: the evidence levels were based on a systematic review of the literature, and the recommendation grades were classified as either strong or weak. The applicability of the guidelines was considered to meet patients' view and preferences in the context of Korea. The topics of the guidelines cover diagnostic modalities (endoscopy, endoscopic ultrasound, and radiologic diagnosis), treatment modalities (surgery, therapeutic endoscopy, chemotherapy, and radiotherapy), and pathologic evaluation. An external review of the guidelines was conducted during the finalization phase.

치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과 (Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography)

  • 이태희;정승훈;김동우;박명환;김태형
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.459-464
    • /
    • 2019
  • 치과 콘빔 전산화단층 검사 시 갑상선 부위의 방사선 피폭선량을 최소화하기 위하여 보루스 (Bolus)를 이용한 차폐체를 제작하고, 방사선 차폐 효과와 영상의 적정성을 평가하였다. 치과용 콘빔 전산화단층검사장비를 사용하여 치과방사선 두부 팬텀을 대상으로 갑상선의 좌, 우측 부위에 유리선량계를 부착시켜 방사선량을 측정하였다. 차폐체의 두께를 각각 10 mm, 20 mm, 30 mm로 다르게 하여 각 차폐체별로 흡수선량을 측정하여 차폐체를 사용하지 않았을 경우와 비교하였다. 8명의 평가자가 진료영상의 적정성을 여부를 평가하였다. 왼쪽 갑상선 부위에 30 mm Bolus 차폐체를 사용한 경우에는 결과값이 평균 $342.67{\mu}Gy$로 Bolus 차폐체를 사용하지 않고 측정한 결과값의 평균 $431.22{\mu}Gy$보다 20.7% 감소하였고, 오른쪽 갑상선 부위에 30 mm Bolus 차폐체를 사용한 경우에는 평균 $424.56{\mu}Gy$로 21.9%의 선량감소효과를 보였다. 진료 영상의 적정성은 평가자 모두 사용 가능하다 판단하였다. 결론적으로, 치과 콘빔 전산화단층검사 시 갑상선 부위의 방사선 피폭선량을 최소화하기 위해 제작된 Bolus 차폐체는 장해음영 없이 적정한 진단 영상 처리가 가능하고, 방사선차폐 효과가 있어 유용한 차폐체로 적용 가능할 것으로 사료된다.

심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발 (Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT)

  • 야마모토토모아키;김정민;이기성;타카야마테루히코;키타하라타다시
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.389-399
    • /
    • 2008
  • 단일광자방출컴퓨터단층촬영(SPECT) 시 정확도의 개선을 위하여 산란과 감약의 보정, 분해능의 개선이 매우 중요하다. 특히 호흡이나 맥동에 대한 심장의 움직임은 보정 에러의 원인이 된다. 심장 팬텀이 보정방법에 대한 검증을 위해 사용되고 있으나, 현재 사용 중인 팬텀들은 실제 인체 데이터와 다른 점이 많이 나타나고 있다. 즉 팬텀을 사용한 결과는 임상데이터와 같게 취급할 수가 없다. 저자들은 흉곽의 인체 구조와 같은 신뢰성 있는 새로운 팬텀을 개발하였다. 새로운 팬텀은 폐와 심장의 전면, 측면 및 상부가 접하는 작은 종격구조를 가지고 있다. 용기는 아크릴로 만들었으며 종격은 물 등가물질을 사용하여 제조하였다. 폐는 에폭시레진의 고형 폴리우레탄 폼을 사용하였다. 5가지 크기의 심장은 게이트 심근관류 SPECT의 정량적 분석을 위하여 개발되었다. 심장팬텀들의 종격은 같은 포지션에 위치할 수 있도록 고안되었다. 완성된 팬텀은 간과 담낭에 부착되고 각각 높이 조절이 가능하다. 5개의 심실의 용적은 각각 150.0, 137.3, 83.1, 42.7과 38.6ml이다. 새로운 팬톰을 사용하여 SPECT 검사를 시행하고 보정법을 적용한 후에 영상의 차이를 검토하였다. 심장의 3차원 단층상이 효율적으로 재구성 되었으며 여러 가지 보정방법의 차이를 나타내기 위하여 주관적 평가도 시행하였다. 저자들은 SPECT영상과 QGS(Quantitative Gated SPECT) 결과로서 보정방법의 차이를 나타낼 수 있는 새로운 팬텀을 개발하여 보고하는 바이다.

  • PDF

Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구 (Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction)

  • 소성수;노현수;김창성;최성호;김기덕;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

가토에서 조직 재생 이식재로서 무세포성 진피 기질의 효용 (USEFULNESS OF ACELLULAR DERMAL MATRIX GRAFT ON THE TISSUE REGENERATION IN RABBITS)

  • 최종학;류재영;유선열
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권2호
    • /
    • pp.220-229
    • /
    • 2008
  • Purpose: The present study was aimed to examine the effect of acellular dermal matrix ($AlloDerm^{(R)}$) grafted to the experimental tissue defect on tissue regeneration. Materials and Methods: Male albino rabbits were used. Soft tissue defects were prepared in the external abdominal oblique muscle. The animals were then divided into 3 groups by the graft material used: no graft, autogenous dermis graft, and $AlloDerm^{(R)}$ graft. The healing sites were histologically examined at weeks 4 and 8 after the graft. In another series, critical sized defects with 8-mm diameter were prepared in the right and left iliac bones. The animals were then divided into 5 groups: no graft, grafted with autogenous iliac bone, $AlloDerm^{(R)}$ graft, $AlloDerm^{(R)}$ graft impregnated with rhBMP-2, and $AlloDerm^{(R)}$ graft with rhTGF-${\beta}1$. The healing sites of bone defect were investigated with radiologic densitometry and histological evaluation at weeks 4 and 8 after the graft. Results: In the soft tissue defect, normal healing was seen in the group of no graft. Inflammatory cells and foreign body reactions were observed in the group of autogenous dermis graft, and the migration of fibroblasts and the formation of vessels into the collagen fibers were observed in the group of $AlloDerm^{(R)}$ graft. In the bone defect, the site of bone defect was healed by fibrous tissues in the group of no graft. The marked radiopacity and good regeneration were seen in the group of autogenous bone graft. There remained the traces of $AlloDerm^{(R)}$ with no satisfactory results in the group of $AlloDerm^{(R)}$ graft. In the groups of the $AlloDerm^{(R)}$ graft with rhBMP-2 or rhTGF-${\beta}1$, there were numerous osteoblasts in the boundary of the adjacent bone which was closely approximated to the $AlloDerm^{(R)}$ with regeneration features. However, the fibrous capsule also remained as in the group of $AlloDerm^{(R)}$ graft, which separated the $AlloDerm^{(R)}$ and the adjacent bone. Conclusions: These results suggest that $AlloDerm^{(R)}$ can be useful to substitute the autogenous dermis in the soft tissue defect. However, it may not be useful as a bone graft material or a carrier, since the bone defect was not completely healed by the bony tissue, regardless of the presence of osteogenic factors like rhBMP-2 or rhTGF-${\beta}1$.