• 제목/요약/키워드: Denture resin

검색결과 281건 처리시간 0.028초

Ultrasonic Cleaning이 Resin 의치상의 안정에 미치는 영향에 관한 실험적 연구

  • 이한무
    • 대한치과의사협회지
    • /
    • 제12권1호
    • /
    • pp.37-42
    • /
    • 1974
  • To ascertain if the ultrasonic cleaning technique caused any dimensional changes in heat and cold curing and fluid resin denture bases and in addition to evaluate the dimensional changes of the resin denture bases stored in water and air, the author measured the distance between the outsides of two pins embedded in methyl methacrylate test denture bases by mean of 12 inch vernier caliper, accurate to 0.02mm. The results were as follows; (1) Ultrasonic cleaning didn't cause any permanent dimensional changes, but only affected temporary dimensional expansion in 16 test denture bases. (2) Temporary expansion rate caused by 10 minutes' ultrasonic cleaning was 0.29% and at the maximal temperature of the cleaning solution it was 0.64%. (3) The half of the denture bases stored in water showed the dimensional expansion rate of 0.47% while the others stored in air showed the dimensional shrinkage rate of 0.15% after 4 months.

  • PDF

섬유의 종류와 조합이 열중합 의치상 레진의 강화에 미치는 영향 (Effect of Fiber Type and Combination on the Reinforcement of Heat Polymerized Denture Base Resin)

  • 유상희;김영임
    • 치위생과학회지
    • /
    • 제10권6호
    • /
    • pp.445-450
    • /
    • 2010
  • 본 연구에서는 열중합 의치상 레진에 유리 섬유, 아라미드 섬유, 폴리에틸렌 섬유를 2.6%, 5.3% 부피비로 첨가하여 섬유의 종류에 따른 강화효과를 평가하고, 각 섬유를 두 가지로 조합한 hybrid FRC를 제작하여 동일 함량의 단독 섬유 FRC보다 굴곡성질이 더 우수한지 평가하고자 하였다. 단독 섬유 FRC에서는 5.3% 부피비의 GL, PE 섬유군의 굴곡강도가 높게 나타났다. 두 가지 섬유 조합FRC의 굴곡강도는 단독 섬유 FRC보다 증가하는 양상을 보였으나, 5.3% GL, PE 섬유군과 유의한 차이가 없었다. 단독 섬유 FRC의 굴곡계수는 5.3% 부피비의 GL 섬유군이 가장 높게 나타났다. 두 가지 섬유 조합FRC의 굴곡계수는 단독 섬유 FRC의 5.3% GL 섬유군보다 높게 나타나 유의한 차이를 보였다. 열중합 의치상 레진의 강화를 위해 섬유를 단독으로 이용할 경우 5.3% 부피비로 첨가한 유리 섬유가 굴곡강도와 굴곡계수 면에서 효과적으로 적용될 수 있을 것으로 본다. 두 가지 섬유 조합FRC의 경우 굴곡강도 면에서는 강화효과가 크지 않았지만, 굴곡계수 면에서 볼 때 유리섬유를 하방에 아라미드 섬유를 그 상방에 위치 시킨 조합을 의치상의 강화에 효과적으로 적용할 수 있을 것으로 본다.

발플라스트 레진 주입 시 발생되는 의치상의 두께변화에 관한 연구 (Research for Thickness Change of Denture Base in Flask when Injecting Valplast Flexible Partial Denture Resin)

  • 장완영;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.47-56
    • /
    • 2008
  • This is a research for thickness change of denture base according to the shape of sprue & investment position of denture base in flask when injecting polyamid base resin for flexible partial denture as a part of study for Valplast among the flexible partial denture with a nylon base. It has been introduced several kinds of flexible partial denture product with a nylon base, but Valplast is the most widely used product among them. Valplast has been the most generally used material today since developed in 1950s in the United States as a material for flexible partial denture. Valplast is much more aesthetic than general metal-acrylic partial denture due to its translucent pink color and biocompatibility in terms of material characteristic. It keeps its flexibility for a long time after production, imposes a less burden on the teeth used as abutment, and it can be easily insert and remove due to its particular suppleness. Moreover, it is felt like real teeth more than metal-acrylic partial denture when being put in and takes alveolar bone under good protection since it receives occlusal force equally under the denture base. The most outstanding feature of Valplast is flexibility. The extent of its flexibility is determined by width & thickness of denture base. Considering general working procedure of Valplast, it can be seen that the thickness of denture base formed out of wax is increasing by the pressure while injecting resin. This research is to decide and test on the thickness increasing of Valplast by injecting pressure and the hypothesis upon that and is to prepare the basis estimating the increasing extent of thickness of denture base on the basis of the test result. In this test, it is expected occlusal malposition & thickness increasing of denture base by injecting pressure according to 4 kinds of test data which are to select 3 types of sprue method settling the forefront position at which the test material of fixed standard can be invested and to position the test material at the rearmost part keeping the minimum distance to set sprue. For 4 kinds of injecting test by investment position & sprue type, 20 test materials, 5 for each test were produced and a pressure of 1,180Kg was given with automatic injector of air cylinder type. The results are as follows: 1. For the amount of thickness increasing of denture base by investment position, the thickness of front investment is less increasing than the one of rear investment. 2. For the amount of thickness increasing of denture base by sprue type, the thickness of straight decompression sprue type which can absorb the injecting pressure after injecting polyamide base resin is less increasing than the other sprue types.

  • PDF

마이크로파 중합에 의한 의치상 레진의 물리적 성질에 관한 연구 (AN EXPERIMENTAL STUDY ON THE PHYSICAL PROPERTIES OF THE DENTURE BASE RESINS CURED BY MICROWAVE IRRADIATION)

  • 김학선;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.109-124
    • /
    • 1990
  • The purpose of this study was to investigate the physical propertise and determine whether three were any differences in the amount of porosity of the denture base resins cured by microwave irradiation and conventional water bath heating. The resins used in this study were K-33 resin and Acron MC resin. The properties selected were transverse strength, Knoop hardness, and density. A ten-power eyepiece and scanning electron microscope(Magnification of ${\times}$ 30and ${\times}$150)were used to examine the specimens for porosity. Through analyses of the data from this study, the following conclusions were obtained. 1. Microwave energy can be effectively use dtopolymerize poly(methylmethacrylate) denture base resins. 2. In the transverse strength, K-33 resin cured by microwave irradiation was the first highest, water bath cured K-33 resin the second, microwave cured Acron MC resin the third, water bath cured Acron MC resin the fourth. 3. In the Knoop hardness, K-33 resin cured by microwave irradiation was the first hardest, water bath cured K-33 resin the second, water bath cured Acron MC resin the third, microwave cured Acron MC resin the the fourth. 4. No significant difference was found between the density of resin denture bases polymerized by either method. 5. K-33 resin showed the most porosity for the microwave curing. But there was no significant difference in the Acron MC resin and other curing method.

  • PDF

대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구 (Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials)

  • 박영배
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

금 합금 및 비 귀금속 합금에 대한 의치상 레진의 결합강도에 관한 연구 (A STUDY ON THE FLEXURAL BOND STRENGTH OF THE GOLD AND THE Co-Cr ALLOY TO THE DENTURE BASE RESINS)

  • 박현주;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.500-509
    • /
    • 2000
  • In general, the three major oral functions of edentulous patients-mastication, phonation, esthetics-can be rehabilitated by the complete dentures, and both the resin based complete denture and the metal based complete denture are commonly used by many clinicians today. For the sake of many advantages such as the excellent thermal conductivity, low volumetric change, high strength, low risk of fracture and the better patient's adaptation, the metal based complete dentures are indicated to the several cases. But, there are common failures of these type of dentures mainly by the fracture or the debonding between the resin structures and the metal frameworks which is caused by the discrepancies of the flexural strength and the coefficient of thermal expansion. This is aggravated by the water contamination of the interface when exposed to the oral environment and results in the failure of complete denture treatment. So, the purpose of this study is to compare the bond strength and the fracture patterns of the gold alloy based and the Co-Cr alloy based complete dentures using the PMMA resins and the 4-META adhesive resins. The results of this study were as follows. 1. Both to the PMMA resin and the 4-META resin, the flexural bond strength of gold alloy is lower than that of Co-Cr alloy(P<0.05) 2. To the Co-Cr alloy, the bond strength of the 4-META resin is significantly higher than that of PMMA resin(P<0.05). 3. The flexural strength of the group with the mechanical retention form is significantly higher than that of the group without retention form(P<0.05). 4. Comparing with the other groups, the fracture patterns of the group 3 are quite different from the group 1,2,5.

  • PDF

Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

  • Thongrakard, Ticha;Wiwatwarrapan, Chairat
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.285-289
    • /
    • 2016
  • PURPOSE. This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (${\alpha}$=.05). RESULTS. The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION. 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

수분함량에 따른 의치접착제의 확장성 관찰 (Spreadability observation of the denture adhesive by the amount of the water)

  • 김종문;최성민
    • 대한치과기공학회지
    • /
    • 제37권1호
    • /
    • pp.17-21
    • /
    • 2015
  • Purpose: In this study, Spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Methods: Examine the spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Also, by measuring the adhesive strength according to the amount of saliva, and the edentulous patients using denture adhesive and dry mouth patients attempt to provide clinical information of the denture adhesive. Therefore, by using the relatively low shrinkage cold curing resin, after fabricating specimen of plate form, for 7 days, it was immersed in water. Results: For the control group only denture adhesive, an artificial saliva for the experimental group were injected in $0.1m{\ell}$, $0.2m{\ell}$ and $0.3m{\ell}$ of the denture adhesive on the surface, experimental results of the investigation of the 10 times the tensile bond strength of the specimens in each group was obtained the following results. Conclusion: As the time to pressure increase in the same amount of saliva was found that the amount coming out of the denture adhesive, as the amount of saliva in the same pressure increase coming out of many denture adhesives. And the greater the pressure came out a lot of denture adhesives. Spreadability in measuring saliva contact with $0.1m{\ell}$ and $2m{\ell}$ and $3m{\ell}$ group pressured the diameter of the circular was the denture adhesive is small when compared to the group without adding the pressure of 2kg and 3kg put the saliva. The size of the circle is the same amount of saliva denture adhesive spread more pressure showed a greater increase.

일부 세치제와 주방세제 사용에 의한 의치상 레진의 표면변화 (Surface changes of denture base resin according to two toothpastes and a kitchen detergent)

  • 강재경;김수화;유은미;최혜숙;최유리;김광만
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.611-620
    • /
    • 2012
  • Objectives : This study evaluated the changes in surface roughness of denture base resin according to the types of denture cleansers. Methods : A denture base resin(Vertex RS, Dentimax, Netherland) was used. Two toothpaste(Antiplaque, Bukwang, Korea; 2080, Aekyung, Korea) and a kitchen detergent(Trio, Aekyung, Korea) were used as a denture cleanser. The specimens were put on the V8 crossbrushing machine(Sabri enterprises, Downers grove, IL, USA) to reproduce toothbrushing and the toothbrushes were flat, round end and soft type. The surfaces of denture base resin specimens were observed by profilometer(SJ-400, MITUTOYO, Japan) and SEM(S-3000N, Hitachi Co., Ibaraki, Japan). Results : 1. According to the result of measuring surface roughness, there was statistically significant difference in Ra, Rq, and Rz(p<0.05). 2. As for Ra, Rq and Rz, Antiplaque toothpaste showed the highest roughness, and there was significant difference from other groups(p<0.01). 2080 toothpaste, Trio, and distilled water were classified as the same group. 3. According to the result of observation with the SEM, the surfaces of the Antiplaque toothpaste group after toothbrushing showed the greatest roughness, and the surfaces of 2080 toothpaste, Trio, and distilled water groups were rough in order. Trio and distilled water had the surfaces similar to those before toothbrushing. Conclusions : Studies to compare the efficacy of denture management methods and examine the effects of denture cleansers on denture materials will be helpful for dental hygienists and dentists providing patients with proper information and education. And it will be also useful for denture users' oral health.