• 제목/요약/키워드: Denture polymers

검색결과 7건 처리시간 0.021초

Physical properties and color stability of injection-molded thermoplastic denture base resins

  • Song, So-Yeon;Kim, Kyoung-Soo;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS. In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS. For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P<.05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION. Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.

무치악 환자에서 총의치 금속상에 대한 고찰 (Metal base of complete denture in edentulous patient)

  • 구철인;이흥태;박찬익
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.197-204
    • /
    • 2002
  • Polymers are the dominant material for fabrication of denture bases. However, resin base can't fufill the patients' satisfactions completely and solve the pronunciation problem and prevent the denture fracture. In spite of many advantages, metal denture bases do not widespread in clinical practice. The main reasons are the difficulties in fabrication and additional time and cost, inability to rebase such prostheses. The use of the metal base can be one of options in complete denture treatments. This study helps, through reveiwing previous reports and literature about the metal base, metal base to be useful in the clinical application by recommend the materials, indications and advantage/disadvantage of the metal base and introduce variable designs. The clinical application of the metal base have many advantages, but the dentists have to select cases carefully and apply designs according to patient's various conditions. In conclusion, the use of the metal base can't alternate treatment of inadequate conventional complete denture. Adequate complete denture is very important for the treatment of the metal base complete denture.

Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer

  • Koodaryan, Roodabeh;Hafezeqoran, Ali
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.504-510
    • /
    • 2016
  • PURPOSE. Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. MATERIALS AND METHODS. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (${\alpha}=.05$). RESULTS. The bond strength values of A and S were significantly higher than those of N (P<.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG (P<.001). CONCLUSION. The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

Flexural properties of a light-cure and a self-cure denture base materials compared to conventional alternatives

  • Mumcu, Emre;Cilingir, Altug;Gencel, Burc;Sulun, Tonguc
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.136-139
    • /
    • 2011
  • PURPOSE. A new light curing urethane dimethacrylate and a cold curing resin with simpler and faster laboratory procedures may have even improved flexural properties. This study investigated the 3-point flexural strengths and flexural moduli of two alternate base materials. MATERIALS AND METHODS. A cold curing resin (Weropress) and a light curing urethane dimethacrylate base material (Eclipse). Along with Eclipse and Weropress, a high impact resin (Lucitone199) and three conventional base materials (QC 20, Meliodent and Paladent 20) were tested. A 3-point bending test was used to determine the flexural strengths and flexural moduli. The mean displacement, maximum load, flexural modulus and flexural strength values and standard deviations for each group were analyzed by means of one-way analysis of variance (ANOVA) (with mean difference significant at the 0.05 level). Post hoc analyses (Scheffe test) were carried out to determine the differences between the groups at a confidence level of 95%. RESULTS. Flexural strength, displacement and force maximum load values of Eclipse were significantly different from other base materials. Displacement values of QC 20 were significantly different from Lucitone 199 and Weropress. CONCLUSION. The flexural properties and simpler processing technique of Eclipse system presents an advantageous alternative to conventional base resins and Weropress offers another simple laboratory technique.

Knitted Glass Fabric 강화 복합레진을 사용한 고정성 치과보철물에 대한 적용성 평가 (A FEASIBILITY STUDY ON THE APPLICATION OF THE KNITTED GLASS FABRIC COMPOSITES TO FIXED PROSTHODONTIC RESTORATION IN DENTISTRY)

  • 정재민;이규복;조광헌
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.429-440
    • /
    • 2002
  • Current dental restorations present a relatively weak resistance to fracture. Owing to their unique mechanical properties, fibre-reinforced polymers are now being considered. Unidirectional or woven continuous fibres, made of glass, polyethylene, carbon or Kevlar, have been evaluated. This study focused on the use of glass fibre knitted fabrics to reinforce acrylate resins, in order to investigate the possibility to construct single crowns as well as three unit bridges. Some points affecting the final composite system were tested ; 1) static strength, with focus on the stress transfer under a occlusal contact point ; 2) modelling of a three nit bridge ; 3) fatigue strength as a posterior three unit bridge material. The study demonstrated that knitted fabric reinforcements are showing an interesting compromise between stiffness, static strength for single crown. For three unit bridge applications in the posterior arch, however knitted glass fabric reinforcements were not strong enough in fatigue An additional reinforcement in the posterior arch fixed partial denture design was recommended.

Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례 (Implant supported prosthesis with high performance polymers using a double scanning method)

  • 강경환;박진홍;이정열;신상완
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.305-310
    • /
    • 2017
  • 최근, CAD/CAM 기술이 발전하면서 하이브리드 보철물의 제작에 이용되고 있다. Double scanning technique은 시적용 납의치와 주모형을 스캔 후 중첩하여, 가상 디자인의 현실화와 보철 기공 과정의 간소화를 이루었다. 본 증례에서는 금속 혹은 지르코니아 대신 고성능 중합체인 Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland)를 framework의 재료로 사용했으며, 콤포짓이나 세라믹 혹은 의치용 치아 대신 Polymethyl methacrylate (PMMA) 비니어링 치아(Visio-lign, Bredent, Senden, Germany)를 최종 보철물로 사용하였다. Pekkton과 Visio-lign을 사용한 본 증례에서 만족할만한 치료 결과와 환자의 만족을 얻었으며, 추후 주기적인 유지관리 및 평가가 필요할 것으로 사료된다.

타이타늄 치근형 매식체에 대한 골유착 과정에 관한 조직학적 연구 (A HISTOLOGIC STUDY OF THE OSSEOINTEGRATION PROCESS TO THE TITANIUM TOOTH ROOT IMPLANT)

  • 안창영;김영수
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.1-28
    • /
    • 1990
  • The severe atrophic edentulism with poor neuromuscular control militates against successful conventional denture therapy. To such situation, a prescribing of dental implant treatment has been considered with some probability. Implant materials used as a trial for dental implants includes metals, plastic polymers and ceramics. The purpose of this study was to observe histologic response in osseointegration process at titanium implant-tissue interface based on biocompatibility at specific period of sequential natures which were divided into a half month, one, month, two months, three months and immediate as a base line. In this study, unilateral lower left premolar and molar teeth were extraced in three dogs. After allowing to heal for 6 months, three kinds of osseointegrated implant, $Br{\aa}nemark$, Corevent and kimplant(a prototype of SNU implant study)were inserted in each dog respectively according to the above sequence from front to back. The specimens were taken from those dogs at the same time since implant were inserted quite reverse order of the specified periods, and decalcified and processed for histologic examination for the light microscopy and the electron microscopy. The microscopic histologic findings at the interface between titanium implants and tissue were interpretated as follows : A. Light microscopic findings : a. Immediate : Implant were surrounded by compact bone and spongy bone. Microcrak was observed in the superficial bone tissue. Osteocytes were disappeared and bone lacunae were observed as a vacant space in some parts. In the contacting with the spongy bone, bone trabeculae and bone marrow were in contact with the implant. b. A half Month : Osteoblasts exist as a monolayer in th inner bone trabeculae and do bone additiocn. Osteoblasts&inflammatory cells were observed in some parts. c. One Month : The presence of osteoclasts decreased. Osteoblasts did active bone fromation, and bone marrow was in contact with the implant in the many places. d. Two Months : Bone formation was advanced in comparison with the b and c. The presence of osteoclsts was not observed. e. Three Months : The superficial bone tissue contacted with the implants was entirely composed by the compact bone. B. Electron microscopic findings : a. A half month and one month group : In the parts of the active bone formation, osteoblasts with the well developed endoplasmic reticulum and Golgi apparatus were arranged in the monolayer. In the parts of the bone resorption, ruffled border was well developed and many osteoclasts with the well-developed golgi apparatus, mitochondria, vacuole, vesicle and lysosome were existed. b. Three months group : No osteoblasts were observed in the superficial bone tissue. Bone matrix with collaen fiber was observed. c. No significant dirrerence in the histologic findings was observed in $Br{\aa}nemark$, Core-vent and kimplant.

  • PDF