• Title/Summary/Keyword: Dentinal hypersensitivity

Search Result 37, Processing Time 0.022 seconds

THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON THE PERMEABILITY OF HUMAN DENTIN (수종의 desensitizing agent가 상아질 투과도에 미치는 영향)

  • Chon, Young-Eui;Jeong, Il-Young;Youn, Tae-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.322-329
    • /
    • 1999
  • The hydrodynamic theory of dentin sensitivity states that movement of tubular contents or tubular fluid, in either direction of dentinal tubule, causes dentin sensitivity. A corollary of that theory is that anything that can decrease dentinal fluid movement or dentin permeability should decrease dentin sensitivity. A wide variety of physicochemical methods have been used to reduce the permeability and sensitivity of exposed dentin. The purpose of this study was to evaluate the ability of 4 kinds of clinical desensitizing agents(2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$, Tubulitec system$^{(R)}$) to reduce the rate of fluid flow through dentin in vitro. Sixty coronal dentin discs, 1mm in thickness, were prepared from extracted third molars, free from decay and wear. Dentin discs were treated with 3% EDTA(Tubulicid Plus$^{(R)}$(Dental Therapeutics AB, Sweden)) to remove the smear layer and debris occluding the tubular orifices. After placing the discs in a split chamber device, the rate at which physiologic saline solution could filter across dentin under 150cm $H_2O$ hydrostatic pressure was measured. The occlusal side of the discs were then treated with MS Coat$^{(R)}$, 2% NaF, Tubulitec system$^{(R)}$, and 30% Potassium oxalate, and the filter ratio of the saline solution was measured again. The following conclusions were drawn : 1. Hydraulic conductance which was measured after the application of desensitizing agents was decreased in all the groups(p<0.05). 2. % change of hydraulic conductance was compared but no significant difference was found among the four desensitizing agents(p>0.05). 2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$ and Tubulitec system$^{(R)}$ decreased the permeability of dentin. It is considered that above four agents can be used in treating the hypersensitive teeth.

  • PDF

The Therapeutic Effects of a Pulsed Nd:YAG Laser on Oral Lesions (구강병소에 대한 펄스형 Nd: YAG 레이저의 치료효과)

  • 신금백
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.309-325
    • /
    • 1997
  • In order to set the lasing variables and evaluate, clinically, the therapeutic effects of a pulsed Nd:YAG laser on oral lesion, the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, Pulse duration 120$\mu$sec, fiber diameter 200$\mu$m/320$\mu$m) to 22 cases of oral soft tissue lesions and 6 cases of oral hard tissue lesions. The obtained results were as follows : 1. The effective excision with contact mode and the effective hemostasis of accompanied bleeding with noncontact mode were occurred by lasing on oral soft tissue lesions with fiber diameter of 320$\mu$m under the variables of 2.0~4.0W and 20~50Hz which were controlled into high power/low pulses for excision, low power/high pulses for hemostasis, low power in granulation tissue and high power in fibrous tissue according to therapeutic goals and tissue conditions. 2. About 50% of decreasing effect on hypersensitivity was occurred by lasing with non-contact and contact mode on cervical abrasion which caused dentinal hypersensitivity with fiber diameter of 320$\mu$m under the variables of 0.7 - 1.0W and 10Hz which were applied 2~3 times with 1 week interval. 3. The effective sterilization of infected root canal and lesion of periapical abscess was occurred by lasing with contact and spiral modes on wall of root canal and periapical abscess with fiber diameter of 200$\mu$m of which the tip was placed about 1mm shorter than root canal length under the variables of 1.OW and 10Hz.

  • PDF

Real-time measurement of dentinal fluid flow during desensitizing agent application (상아질 지각과민 처치제의 적용 중에 일어나는 상아세관액 유동의 실시간 측정)

  • Kim, Sun-Young;Kim, Eun-Joo;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.313-320
    • /
    • 2010
  • Objectives: The aim of this study was to examine changes in the dentinal fluid flow (DFF) during desensitizing agent application and to compare permeability after application among the agents. Materials and Methods: A Class 5 cavity was prepared to exposure cervical dentin on an extracted human premolar which was connected to a sub-nanoliter fluid flow measuring device (NFMD) under 20 cm water pressure. DFF was measured from before application of desensitizing agent (Seal&Protect, SP; SuperSeal, SS; BisBlock, BB; Gluma desensitizer, GL; Bi-Fluoride 12, BF) through application procedure to 5 min after application. Results: DFF rate after each desensitizing agent application was significantly reduced when compared to initial DFF rate before application (p < 0.05). SP showed a greater reduction in DFF rate than GL and BF did (p < 0.05). SS and BB showed a greater reduction in DFF rate than BF did (p < 0.05). Conclusions: Characteristic DFF aspect of each desensitizing agent was shown in NFMD during the application procedure.

AN IN VITRO STUDY OF THE THERAPEUTIC EFFECT OF ARGON LASER IRRADIATION ON HYPERSENSITIVE ROOTS (과민성치근에 대한 Argon laser조사의 치료효과에 관한 실험적 연구)

  • Chang, Kap-Sung;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.668-678
    • /
    • 1995
  • In order to evaluate the therapeutic effect of argon laser irradiation on hypersensitive root, 60 mandibular premolars that had been extracted due to periodontal disease were treated by thorough scaling, root planing and root conditioning with tetracycline HCI(100mg/ml, 5 min.) for induction of hypersensitive root. Within middle one third of root mesial surface(30) or distal surface(30) was randomly irradiated by 0.5W-, 0.75W- and 1.0W-power for 2 minutes argon laser(HGM Inc., USA) with or without topical application of 1.23% acidulated phosphate fluoride gel(Pascal, USA). After all teeth were maintained in 2% methylene blue solution for 48 hours and cross-sectioned through irradiated surface of dried roots, methylene blue stained area was compared between irradiated side and nonirradiated side. Following results were obtained : 1. Methylene blue stained area was significantly less in the laser irradiated group than control group(p<0.05). 2. There was no significant difference in methylene blue stained area between 0.5W-power and 0.75W-power group(p>0.1) and between 0.75W-power and 1.0W-power group(p>0.1), but there was significant difference between 0.5W-power and 1.0W-power group(p<0.05). 3. There was no significant difference in methylene blue stained area between two groups with and without topical application of 0.12% acidulated phosphate fluoride gel(p>0.1). The results suggest that argon laser irradiation on hypersensitive root may reduce the hypersensitivity by obstruction of dentinal tubules.

  • PDF

A Clinical Study on the Therapeutic Effects of the Pulsed Nd:YAG Laser on Dentinal Hypersensitivity (상아질지각과민증에 대한 펄스형 Nd: YAG 레이저의 치료효과에 관한 임상적 연구)

  • 최순정;신금백;김문현
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.11-20
    • /
    • 1998
  • 저자는 치과용 레이저를 이용한 상아질지각과민증 치료효과를 임상적으로 평가하고자 상아질지각과민증환자 24명을 대상으로 각 환자마다 상아질 지각과민 치아 중 레이저로 치료 할 치아1개(실험군)와 치료하지 않을 치아 1개(대조군)를 선정하여, 치과용 air-syringe에 의한 냉자극과 치과용 탐침자에 의한 기계적 자극을 가한 후 Visual Analogue Scale(VAS)을 통해 지각과민증 정도를 평가하였으며, 이후 실험군 치아의 치경부 마모면에 광섬유 레이저에너지 전달방식의 펄스형 Nd:YAG 레이저의 일종인 Sunlase Master(Sunrise Technologies Inc., U.S.A., 파장 1064nm, 펄스지속시간 120(sec, 광섬유직경 320(m)를 사용하여, 0.3-1.0W, 10Hz 조건으로 환자의 반응에 따라 1회2분을 초과하지 않는 범위 내에서 비접촉식과 접촉식을 병행하여 3회에 걸쳐(초진 당일, 1일후, 3일후) 레이저를 조사한 후 처음조사 직후, 그리고 초진 1일후, 3일후, 7일후, 14일후 VAS를 채득하여 조사전과 비교, 분석, 평가하였던 바, 상아질 지각과민증이 각각 약 50%, 약36%, 약45%, 약 53% 감소하였으나 (p(0.05) 경시적으로는 유의한 차이를 보이지 않았다. 그리고 24명중 9명에 대해서는 초진 30일 후 까지 레이저조사치료효과를 평가하였던 바, 상아질지각과민증이 처음조사 직후, 감소하였으며 (p(0.05)역시 경시적으로는 유의한 차이를 보이지 않았다. 초진 30일 후 상아질지각과민증이 초진 14일 후에 비해 약간 증가되는 경향을 보여, 레이저조사 치료효과가 약화되는 경향인지 여부에 대해 향후 추가적인 연구가 필요할 것으로 사료된다.안되었다.기란 현실적으로 불가능하므로, 본 연구에서는 이러한 제약점을 극복할 수 있는 근사적인 지체시간을 계산하는 방법을 제시한 점에서 의미를 갖을 수 있다.수들은 직업의 선택이나 소득을 예측하기 위한 요소들로 포함될 수 없었다. 따라서 후속연구에서는 이를 보완해야 할 것이며, 최근 들어 우리 나라에서도 재택근무에 대한 관심이 대두되고 있으나 아직 개념정의나 그 중요성과 가치, 그리고 실태 파악과 같은 연구가 활발히 이루어지지 못하고 있으므로 이에 대한 심층적인 연구가 행해져야 할 것이다.d similar flower proceeding dates in all branches. but "Daepung" showed similar flower proceeding dates in all branches.est in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.ANCOVA, Pearson correlation을 이용하여 분석하였으며, 그 결과는 다음과 같다. 캠프 프로그램은 소아 당뇨병 환자의 자기 효능을 증진시키고 환자 역할 행위 이행을 높여주는데 효과적 이었다. 소아 당뇨병 환자의 자기 효능은 환자 역할 행위 이행과 순 상관 관계가 있어, 자기 효능이 증진될수록 환자 역할 행위 이행 정도가 높아졌다. 무조건 사주지 않는다(8.0%), 무조건 사준다(3.1%)로 식품광고에 나오는 식품 요구시 부모의 70.3%가 거절하는 것으로 나타났다. 거절 이유는 건강에 나쁘다는 것이 가장 큰 이유였으며 강남과 강북 어린이간에 유의적인 차이가 있었다(p<0.001).

  • PDF

THE EFFECT OF Er,Cr:YSGG IRRADIATION ON MICROTENSILE BOND STRENGTH OF COMPOSITE RESIN RESTORATION (Er,Cr:YSGG 조사가 복합레진 수복의 미세인장 결합강도에 미치는 영향)

  • Son, Jeong-Hye;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.134-142
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of Er,Cr:YSGG laser irradiation with hypersensitivity mode on microtensile bond strength of composite resin. Twenty extracted permanent molars were randomly assigned to six groups, according to the irradiation of Er,Cr:YSGG laser, adhesive system (Optibond FL or Clearfil SE bond) and application time of etchant (15 sec or 20 sec). Then composite resin was build up on each conditioned surface. The restored teeth were stored in distilled water at room temperature for 24 h and twelve specimens for each group were prepared. All specimens were subjected to microtensile bond strength and the fracture modes were evaluated. Also, the prepared dentin surface and laser irradiated dentin surface were examined under SEM. The results were as follows: 1. The microtensile bond strength of laser irradiated group was lower than that of no laser irradiated group. 2. Regardless of laser irradiation, the microtensile bond strength of Optibond FL was higher than that of Clearfil SE bond. And the microtensile bond strength of 20 sec etching group was higher than that of 15 sec etching group when using Optibond FL. 3. The SEM image of laser irradiated dentin surface showed prominent peritubular dentin, opened dentinal tubules and no smear layer.

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.