• Title/Summary/Keyword: Dentin permeability

Search Result 16, Processing Time 0.025 seconds

THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON THE PERMEABILITY OF HUMAN DENTIN (수종의 desensitizing agent가 상아질 투과도에 미치는 영향)

  • Chon, Young-Eui;Jeong, Il-Young;Youn, Tae-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.322-329
    • /
    • 1999
  • The hydrodynamic theory of dentin sensitivity states that movement of tubular contents or tubular fluid, in either direction of dentinal tubule, causes dentin sensitivity. A corollary of that theory is that anything that can decrease dentinal fluid movement or dentin permeability should decrease dentin sensitivity. A wide variety of physicochemical methods have been used to reduce the permeability and sensitivity of exposed dentin. The purpose of this study was to evaluate the ability of 4 kinds of clinical desensitizing agents(2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$, Tubulitec system$^{(R)}$) to reduce the rate of fluid flow through dentin in vitro. Sixty coronal dentin discs, 1mm in thickness, were prepared from extracted third molars, free from decay and wear. Dentin discs were treated with 3% EDTA(Tubulicid Plus$^{(R)}$(Dental Therapeutics AB, Sweden)) to remove the smear layer and debris occluding the tubular orifices. After placing the discs in a split chamber device, the rate at which physiologic saline solution could filter across dentin under 150cm $H_2O$ hydrostatic pressure was measured. The occlusal side of the discs were then treated with MS Coat$^{(R)}$, 2% NaF, Tubulitec system$^{(R)}$, and 30% Potassium oxalate, and the filter ratio of the saline solution was measured again. The following conclusions were drawn : 1. Hydraulic conductance which was measured after the application of desensitizing agents was decreased in all the groups(p<0.05). 2. % change of hydraulic conductance was compared but no significant difference was found among the four desensitizing agents(p>0.05). 2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$ and Tubulitec system$^{(R)}$ decreased the permeability of dentin. It is considered that above four agents can be used in treating the hypersensitive teeth.

  • PDF

Effects of dentin surface preparations on bonding of self-etching adhesives under simulated pulpal pressure

  • Chantima Siriporananon;Pisol Senawongse;Vanthana Sattabanasuk;Natchalee Srimaneekarn;Hidehiko Sano;Pipop Saikaew
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.4.1-4.13
    • /
    • 2022
  • Objectives: This study evaluated the effects of different smear layer preparations on the dentin permeability and microtensile bond strength (µTBS) of 2 self-etching adhesives (Clearfil SE Bond [CSE] and Clearfil Tri-S Bond Universal [CTS]) under dynamic pulpal pressure. Materials and Methods: Human third molars were cut into crown segments. The dentin surfaces were prepared using 4 armamentaria: 600-grit SiC paper, coarse diamond burs, superfine diamond burs, and carbide burs. The pulp chamber of each crown segment was connected to a dynamic intra-pulpal pressure simulation apparatus, and the permeability test was done under a pressure of 15 cmH2O. The relative permeability (%P) was evaluated on the smear layer-covered and bonded dentin surfaces. The teeth were bonded to either of the adhesives under pulpal pressure simulation, and cut into sticks after 24 hours water storage for the µTBS test. The resin-dentin interface and nanoleakage observations were performed using a scanning electron microscope. Statistical comparisons were done using analysis of variance and post hoc tests. Results: Only the method of surface preparation had a significant effect on permeability (p < 0.05). The smear layers created by the carbide and superfine diamond burs yielded the lowest permeability. CSE demonstrated a higher µTBS, with these values in the superfine diamond and carbide bur groups being the highest. Microscopic evaluation of the resin-dentin interface revealed nanoleakage in the coarse diamond bur and SiC paper groups for both adhesives. Conclusions: Superfine diamond and carbide burs can be recommended for dentin preparation with the use of 2-step CSE.

DENTIN PERMEABILITY CHANCE ACCORDING TO THE PROCESS OF COMPOMER RESTORATION (컴포머 충전과정에 따른 상아질 투과도의 변화)

  • Cho, Hye-Jin;Lee, Kyung-Ha;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.382-388
    • /
    • 2002
  • Compomer is composed of matrix and filler : matrix is made of the combination of resins and polycarboxylic molecules that are light-cured, and a filler is a glass component which is capable of ion-release. The resin content of compomers produces polymerization shrinkage which can adversely affect marginal adaptation. Pretreatment is a fundamental step which is treated with conditioner or primer in the use of these materials. Microleakage of restorative materials has been investigated mostly by dye penetration method. Dye penetration method was not quantitative and not measured repeatedly. Fluid filtration method, introduced and developed by Pashley's group, has been extensively used for 20 years for research purpose to understand the physiology of dentin, as well as the effects of various restorative treatments on dentin permeability. It permits quantitative, nondestructive measurment of microleakage in a longitudinal manner. The purpose of this study was to evaluate the change of dentin permeability according to the process of compomer restoration. In this study. Cl V cavities were prepared on buccal surface of thirty extracted human molars. The prepared cavities were etched by 37% phosphoric acid. The experimental teeth were randomly divided into three groups. Each group was treated with following materials Group 1 : Prime & Bond NT/Dyract AP, Group2: Single Bond/F2000 compomer, Group 3 : Syntac Single Component/Compoglass. The bonding agent and compomer were applied for each group following manufacturers information. Dentin permeability of each group was measured at each process by fluid filtration method; Step 1 : preparation(smear layer). Step 2 : etching(smear layer removal), Step 3 : applying the bonding agent, Step 4 : filling the compomer. Dentin permeability was expressed by hydraulic conductance ($\mu\textrm{l}$ min$^{-1}$cm$H_2O$$^{-1}$). The data were analysed statistically using One-way ANOVA and Sheffe's method. The results were as follows : 1. Dentin permeability differences between each process were significant except between step 1 and step 2(p<0.01). 2. Dentin permeability after removal of smear layer was highly increased(p<0.01). 3. In most case, decrease of dentin permeability was obtained by applying bonding agent(p<0.01). 4. Dentin permeability differences among the experimental groups were not significant(p>0.05). 5. None of compomers used in this study showed perfect seal at the interface.

THE EFFECTS OF DESENSITIZING AGENTS AND TOOTH BRUSHING ON DENTIN PERMEABILITY, IN VITRO (지각과민 처치제 도포 후 칫솔질에 의한 마모가 상아질 투과도에 미치는 영향)

  • Lee Jong-Wook;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.208-219
    • /
    • 2001
  • To study the effect of dentin permeability on a tooth with wear from tooth brushing after application of desensitizing agent, extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance, scanning electron microscope images(SEM) and atomic force microscope images(AFM) were compared and contrasted before and immediately after the application of desensitizing agent and after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study ; they were Gluma, Seal & Protect, All-Bond 2 and MS Coat. The results of this study are as follows. 1. On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent. 2. Except the specimens treated with MS Coat, the remaining specimens had an increase in dentin permeability after tooth brushing for 1 and 2 weeks but a decrease after 6 weeks. 3. The specimens treated with MS Coat had statistically significant increase in the dentin permeability regardless with the duration of tooth brushing. 4. On examination of SEM and AFM, the dentinal tubule diameter had decreased after treatment of desensitizing agents. The specimens other than those treated with MS Coat, smear layers were noted after tooth brushing. It is not always consistant but the hydraulic conductance correlated with the images from SEM and AFM.

  • PDF

Dentin permeability change according to the process of compomer restoration treatment

  • Cho, Hye-Jin;Lee, Kwang-Won;Lee, Se-Jun
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.591.2-591
    • /
    • 2001
  • Microleakage of restorative materials has been investigated mostly by dye penetration method. Dye penetration method was not quantitative and not measured repeatedly. Fluid filtration method was used to research purpose to understand the effects of various restorative treatments on dentin permeability. The purpose of this study was to evaluate of dentin permeability according to the process of compomer restoration treatment. In this study, C1 V cavities were prepared on buccal surface of thirty extracted human molars. The prepared cavities were etched by 37% phosphoric acid.(omitted)

  • PDF

THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY (치과용 지혈제가 상아질 투과도에 미치는 영향)

  • Kim, Chong-Hyun;Shim, June-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

EXPERIMENTAL STUDY ON PENETRATION OF ROOT CANAL DENTINE (치근관상아질(齒根管象牙質)의 침투도(浸透度)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Yang, Moon-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 1975
  • This study is to determine the penetration of various medicaments such as Howe's ammoniacal silver nitrate and methyleneblue, to root canal dentin within given time (5,10,30 sec.) Followings are the results obtained from this study. 1) The dye stuff is more deeply penetrated according to the time elapsed. 2) According to the increase of age, the penetration ratio is decreased accordingly. 3) The penetration ratio of Howe's ammoniacal silver nitrate is higher than that of methyleneblue. 4) The permeability of the root canal dentin is gradually reduced as access to the apex.

  • PDF

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.

Effect of the additional application of a resin layer on dentin bonding using single-step adhesives (중간층 레진 적용이 단일 접착과정 상아질 접착제의 접착에 미치는 영향)

  • Choi, Seung-Mo;Park, Sang-Hyuk;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.313-326
    • /
    • 2007
  • The purpose of this study was to prove that an intermediate resin layer (IRL) oan increase the bond strength to dentin by reducing the permeability of single-step adhesives. Flat dentin surfaces were created on buccal and lingual side of freshly extracted third molar using a low-speed diamond saw under copious water flow. Approximately 2.0 mm thick axially sectioned dentin slice was abraded with wet #600 SiC paper. Three single-step self-etch adhesives; Adper Prompt L-Pop (3M ESPE, St Paul, MN, USA), One-Up Bond F (Tokuyama Corp, Tokyo, Japan) and Xeno III (Dentsply, Konstanz, Germany) were used in this study. Each adhesive groups were again subdivided into ten groups by; whether IRL was used or not; whether adhesives were cured with light before application or IRL or not; the mode of composite application. The results of this study were as follows; 1. Bond strength of single-step adhesives increased by an additional coating of intermediate resin layer, and this increasement was statistically signigicant when self-cured composite was used (p < 0.001). 2. When using IRL, there were no difference on bond strengths regardless the curing procedure of single-step adhesives. 3. There were no significant difference on bond strengths between usage of AB2 or SM as an IRL. 4. The thickness of Hybrid layer was correlated with the acidity of adhesive used, and the nanoleakage represented by silver deposits and grains was examined within hybrid and adhesive layer in most of single-step adhesives. 5. Neither thickness of hybrid layer nor nanoleakage were related to bond strength.