• 제목/요약/키워드: Dentin bonding systems

검색결과 74건 처리시간 0.029초

Solvent-induced Expansion & Shrinkage of Demineralized Dentin Matrix

  • Lee, Kwang-Won
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.580-580
    • /
    • 2001
  • Before resin composites can serve as durable substitutes for amalgam restorations, the adhesive system used to retain them and add to seal dentin must be improved. The recent observations, using the newly developed LVDT (linear variable differential transformer) probe, that all commercial bonding systems cause a collapse of the demineralized dentin matrix, simulated a re-evaluation of the effects of these formulations on the matrix. The experiment was begun by examining solvents such as water-HEMA mixtures. These produced the same shrinkages as did the complete formulations.(omitted)

  • PDF

타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향 (EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS.)

  • 최경규;류길주
    • Restorative Dentistry and Endodontics
    • /
    • 제28권3호
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.

임상가를 위한 특집 1 - 간접 복합레진 수복의 이론과 실제 (Indirect Composite Restoration)

  • 황인남;장지현
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.368-376
    • /
    • 2012
  • The demand for tooth-colored restorations has grown considerably during the last decade. Posterior composite restorations have risen in popularity as a result of the development of improved resin composites, bonding systems and operating techniques. A major limitation of direct composite restoration is the difficulty of controlling the polymerization shrinkage. To overcome this limitation, the indirect fabrication of a composite restoration and cementation with resin cement has been advocated. Unfortunately, the current available resin cements with indirect restorations do not always bond to dentin as strongly as dentin adhesive systems bond with direct resin composite restorations. Several procedural strategies have been proposed for indirect composite restoration. In this regard, the rationale for the indication, characteristics and clinical application is described in this paper. As a result, we will try to suggest the evidence-based guidelines for indirect composite restorations by reviewing each available indirect composite products, technical procedure and pronosis.

상아질-레진 계면의 공초점 현미경적 형태 및 전단결합강도와의 관계 (CONFOCAL LASER SCANNING MICROSCOPIC MORPHOLOGY OF DENTIN-RESIN INTERFACE AND ITS RELATIONSHIP WITH SHEAR BOND STRENGTH)

  • 최낙원;조병훈;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.310-321
    • /
    • 1999
  • In this in vitro study, confocal laser scanning microscopic morphology of dentin-resin interface and its relationship to shear bond strength were investigated after the exposed dentin surfaces were treated with 3 different kinds of dentin adhesive systems[three-step; Scotchbond Multi-Purpose Plus(SMPP), self-priming bonding resin; Single Bond(SB), self-etching primer; Clearfil Liner Bond 2(LB2)]. 52 extracted human molar teeth without caries and/or restorations. The experimental teeth were randomly divided into three groups of seventeen teeth each. In five teeth of each group, class V cavities(depth: 1.5mm) with 900 cavosurface angles were prepared at the cementoenamel junction on buccal and lingual surfaces. Bonding resins of each dentin adhesive system were mixed with rhodamine B. Primer of SMPP was mixed with fluorescein. In group 1. the exposed dentin was conditioned with etchant, applied with above primer and bonding resin of SMPP. In group 2, with etchant and self-priming bonding agent of SB. In group 3, with self-etching primer and bonding agent of LB2. After treatment with dentin adhesive systems, composite resin were applied and photocured. The experimental teeth were cut longitudinally through the center line of restoration and grounded so that about $90{\mu}m$-thick wafers of buccolingually orientated dentin were obtained. And, $70{\sim}80{\mu}m$-thick wafers sectioned horizontally, thus presenting a dentinal tubules at 900 to the cut surface of a remaining tooth, were obtained. Primer of SMPP mixed with rhodamine B was applied to these wafers. Confocal laser scanning microscopic investigations of these wafers were done within of 24 hours after treatment. To measure shear bond strength, the remaining twelve teeth of each group were grounded horizontally below the dentinoenamel junction, so that no enamel remained. After applying dentin adhesive systems on the dentin surface, composite was applied in the shape of cylinder. The cylinder was 5mm in diameter, and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. It was concluded as follows ; 1. Hybrid layer of SMPP(mean: $4.56{\mu}m$) was thicker than that of any other groups. This value was not statistically significant thicker than that of SB(mean: $3.41{\mu}m$, p>0.05), and significant thicker than that of LB2(mean: $1.56{\mu}m$, p<0.05). There was a statistical difference between SB and LB2(p<0.05). 2. Although there were variations in the length of resin tag even in a sample, and in a group, most samples in SMPP and SB showed resin tags extending above $20{\mu}m$. But samples in LB2 showed resin tags of $10{\mu}m$ at best. 3. Besides primer's infiltration into demineralized peritubular dentin and dentinal tubules, fluorophore of primer was detected in the lateral branches of dentinal tubules. 4. All groups demonstrated statistically significant differences from one another(p<0.05), with shear bond strengths given in descending order as follows: SMPP(18.3MPa), SB(16.0MPa) and LB2(12.4MPa). 5. LB2 having thinnest hybrid layer($1.56{\mu}m$) showed the lowest shear bond strength(12.4MPa).

  • PDF

One-Bottle system 상아질접착제의 전단결합강도 해석 (SHEAR BOND STREGNTHS OF ONE-BOTTLE DENTIN ABHESIVE SYSTEMS)

  • 조병훈;임성삼;권혁춘;엄정문;손호현;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.546-553
    • /
    • 1999
  • In Older to evaluate the effectiveness of 'One-bottle dentin adhesive system', the shear bond strengths of two fourth generation dentin adhesive systems and two One-bottle systems to the occlusal dentin of the freshly extracted third molars were measured by the regulation of the ISO TR 11405. The fourth generation dentin adhesive systems used in this study were Scotchbond Multi-Purpose Plus and All-Bond 2, and the One-bottle systems were Single Bond and One-Step. The effects of the thickness of hybrid layer and adhesive layer, the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule were analyzed as the contributing factors of the shear bond strength of dentin bonding systems from the Scanning Electron Microscopic images. The results were as follows: 1. The shear bond strengths of Scotchbond Multi-Purpose, All-Bond 2, and Single Bond were 16.98${\pm}$3.40 MPa, 15.10${\pm}$2.77 MPa and 15.05${\pm}$3.18 MPa, respectively. There were no statistical differences(p>0.05). 2. But, the shear bond strength of One-Step were significantly lower than those of the other groups (11.81${\pm}$1.95 MPa, p<0.05). 3. The thicknesses of hybrid layer and adhesive layer of One-Step were significantly thinner than those of the other groups(p<0.05). The differences of the diameter of resin tag(p=0.0685) and the ratio between the diameter of resin tag and that of dentinal tubule(p=0.2401) were not significant among all the material groups. 4. The thickness of hybrid layer and adhesive layer might be considered as contributing factors of the she at bond strengths of dentin bonding systems, but the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule might not.

  • PDF

Er:YAG 레이저로 삭제된 상아질에 대한 컴포지트 레진의 미세인장결합강도에 관한 연구 (Micro-tensile Bond Strength of Composite Resin Bonded to Er:YAG Laser-prepared Dentin)

  • 민숙진;안용우;고명연;박준상
    • Journal of Oral Medicine and Pain
    • /
    • 제31권3호
    • /
    • pp.211-221
    • /
    • 2006
  • 목적 전통적 고속 회전식 절삭기구 또는 Er:YAG 레이저로 삭제된 상아질에, 두가지 다른 접착 시스템을 적용한 후, 축조한 컴포지트 레진의 미세인장결합강도를 비교하고, 다양한 Er:YAG 레이저 에너지가 미세인장결합강도에 미치는 영향을 평가한다. 재료 및 방법 40개의 제3대구치를 사용하여, 평평한 상아질면을 만든 후 8개의 군으로 나누어, 4가지 절삭방법 (고속 회전식 절삭기구, 2 W, 3 W, 4 W 출력의 Er:YAG 레이저) 중 한 가지로 삭제하고, 2가지 접착 시스템 (Scotchbond Multipurpose Plus, Clearfil SE bond) 중 한 가지로 처리하여 컴포지트 레진을 축조하였다. 24시간의 저장 후, 각 시편을 결합면에 수직으로 자르고, 미세인장결합강도를 측정하였다. 각 군의 미세인장결합강도는 평균$\pm$표준 편차로 표현하였고, 통계분석을 위해 two-way ANOVA, one-way ANOVA, student-Newman-Keuls' multiple comparison test, 그리고 t-test가 사용되었다. 결과 및 결론 1. 접착시스템과 관계없이, 절삭방법에 따른 미세인장결합강도의 유의한 차이가 있었고, 높은 순서대로 나열하면 다음과 같다: 3 W, 2 W, Bur, 4 W (p<0.001). 2. 절삭방법과 관계없이, Scotchbond Multipurpose Plus로 처리한 군이 Clearfil SE bond로 처리한 군보다 유의하게 높은 미세인장결합강도를 나타냈다 (p<0.001). 3. Scotchbond Multipurpose Plus로 처리한 군 중에서, 3 W 레이저 절삭군이 가장 높은 미세인장결합강도를 나타냈고, 다음이 Bur, 2 W, 4 W 절삭군 순이었다 (p<0.001). 4. Clearfil SE bond로 처리한 군 중에서 3 W 레이저 절삭군이 가장 높은 미세인장결합강도를 나타냈고, 다음이 2 W, 4 W, Bur 절삭군 순이었다 (p<0.001). 5. 두 가지 접착 시스템 모두에서, 레이저로 절삭한 군의 미세인장결합강도의 차이가 있었고, 높은 순서대로 나열하면 3 W, 2 W, 4 W 순이었다 (p<0.001). :상아질에 접착된 컴포지트 레진의 미세인장결합강도는 절삭방법과 접착시스템의 상호작용에 의해 유의한 영향을 받았다. 임상에서 레진 수복시, 2 W-3 W 범위내로 Er:YAG laser를 사용한다면 전통적 핸드피스 못지않게 수복물의 우수한 결합강도를 얻을 수 있다. 특히 시술시간의 단축, 과도한 산부식에 따른 부작용의 예방을 위해 Clearfil SE bond를 포함한 self etching system을 사용하고자 한다면 bur보다 Er:YAG laser를 이용한 삭제방법이 더 유용한 결합력을 제공할 것이다.

수종 상아질 접착제의 결합강도와 중합률에 관한 연구 (A STUDY ON BONE STRENGTH AND THE DEGREE OF CONVERSION OF DENTIN BONDING AGENTS)

  • 김병현;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.68-93
    • /
    • 1998
  • The physical properties of polymer are greatly influenced by the extent to which a resin cures. The presence of un reacted monomer can, have a plasticizing effect on the polymer, thereby altering the physical and mechanical properties of dentin bonding agent (DBA). If the DBA does not polymerize sufficiently, it will leave a weak bonding layer and lead to lower bond strength. The purpose of this study was to evaluate the shear bond strengths(SBS) and the degree of conversion (DC) of 4 commercialy avilable dentin bonding systems which are composed of 2 multi-bottle systems [Scotchbond Multi-Purpose (SMP), AeliteBond(AB)] and 2 onebottle systems [SingleBond(SB), One-Step(OS)]. For shear bond strength measurement, labial surfaces of freshly extracted bovine incisors were ground with # 600 grit SiC paper to expose dentin. Four different groups of samples were formed, with 10 samples. being made for each of the 4 commercial DBA in each group according to the curing sequences of DBA and overlayer thickness of composites: Group I (standard cure and 1mm thick composites) : The DBA was light cured and the composites of 1mm thickness was applied ; Group II (standard cure and 2mm thick composites) : The DBA was light cured and the composites of 2mm thickness was applied; Group III (simultaneous cure and 1mm thick composites) : The DBA was not light-cured and simultaneously cured with composites of 1mm thickness; Group N (simultaneous cure and 2mm thick composites) : The DBA was. not light-cured and simultaneously cured with composites of 2mm thickness. The SBS was measured immediately after the composites was bonded to the bovine dentin using an Instron machine. The DC of the DBA was examined in a thin film under simulated conditions of the experimental groups according to the curing sequences and overlayer thickness of composites in the SBS test. using a Fourier transform Infrared(FTIR) spectrometer. The following results were obtained from SBS tests and DC measurements 1. In SBS tests, the multi-bottle DBA(SMP, AB) had a generally higher bond strength values than the one bottle DBA(SB, OS). In DC measurements, the one bottle DBA(SB, OS) had a significantly higher DC than the multi-bottle DBA(SMP, AB). 2. In all DBAs except OS, there was no significant difference between the bond strength of group I (standard cure and 1mm thick composites) and that of group III (simultaneous cure and 1mm thick composites). SMP, SB in Group I had a significantly higher DC than those in group III, but AB, OS in group I had a significantly lower DC than those in group III 3. All DBAs in Goup II (standard cure and 2mm thick composites) had significantly higher bond strength and DC than those in Group N (simultaneous cure and 2mm thick composites). 4. In all DBAs, there was no significantly different SBS and DC between Group I and Group II, but all DBAs in Group III had significantly higher SBS and DC than those in Group IV.

  • PDF

미세-전단 결합 강도 시험을 이용한 상아질 접착제와 수복용 복합 레진의 호환성에 관한 연구 (IN VITRO MICRO-SHEAR BOND STRENGTH OF FIVE COMPOSITE RESINS TO DENTIN WITH FIVE DIFFERENT DENTIN ADHESIVES)

  • 정진호;노병덕
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.353-364
    • /
    • 2004
  • The purpose of this study was to compare and to evaluate the combination use of 5 kinds of dentin adhesive systems and 5 kinds of composite resins using micro-shear bond test. Five adhesive systems (Prime & Bond NT (PBN). Onecoat bond (OC), Excite (EX), Syntac (SY), Clearfil SE bond (CS)) and five composite resins (Spectrum (SP), Synergy Compact (SC), Tetric Ceram (TC), Clearfil AP-X (CA), Z100 (Z1)) were used for this study ($5{\;}{\times}{\;}5{\;}={\;}25group$, n =14/group). The slices of horizontally sectioned human tooth were bonded with each bonding system and each composite resin, and tested by a micro-shear bond strength test. These results were analyzed statistically. The mean micro-shear bond strength of dentin adhesive systems were in order of CS (22.642 MPa), SY (18.368 MPa), EX (14.599 MPa). OC (13.702 MPa). PBN (12.762 MPa). The mean bond strength of self-etching primer system group (CS, SY) in dentin was higher than that of self-priming adhesive system groups (PBN, EX, OC) significantly (P<0.05). The mean bond strength of composite resins was in order of SP (19.008 MPa), CA (17.532 MPa). SC (15.787 MPa), TC (15.068 MPa). Z1 (14.678 MPa). Micro-shear bond strength of SP was stronger than those of other composite resins significantly (P < 0.05). And those of TC and Z1 were weaker than other composite resins significantly (P < 0.05). No difference was found in micro-shear bond strength of composite resin in self-etching primer adhesive system groups (CS, SY) statistically. However, there was significant difference of micro-shear bond strength of composite resin groups in self-priming adhesive systems group (PBN, EX, OC). The combination of composite resin and dentin adhesive system recommended by manufacturer did not represent positive correlation. It didn't seem to be a significant factor.

수종의 상아질 접착시스템이 즉시 및 지연 상아질 봉쇄의 미세인장결합강도에 미치는 영향 (THE EFFECT OF VARIOUS BONDING SYSTEMS ON THE MICROTENSILE BOND STRENGTH OF IMMEDIATE AND DELAYED DENTIN SEALING)

  • 하진희;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.526-536
    • /
    • 2008
  • 이 연구의 목적은 수종의 상아질 접착시스템이 즉시 및 지연 상아질 봉쇄에서 미세인장결합강도에 미치는 영향을 평가하는 것이었다. 18개의 발거된 대구치를 사용하여 지연 상아질 봉쇄그룹은 노출된 상아질면을 임시수복하였으며, 1주간 보관 후, 접착제에 따라 3개의 소그룹으로 나누어 도포하였다; SB 그룹 (3 단계 산 부식 접착제), SE 그룹 (2단계 자가 부식 접착제), XE 그룹 (1단계 자가 부식 접착제). 즉시 상아질 봉쇄그룹은 3개의 소그룹으로 나누어 접착제를 도포하고 임시수복 후 1주간 보관하였다. 모든 시편은 간접 복합레진과 레진 시멘트로 합착하고 미세인장결합강도를 측정하여, 다음과 같은 결과를 얻었다. 1. 즉시 상아질 봉쇄그룹은 지연 상아질 봉쇄그룹에 비해 3단계 산 부식과 2단계 자가 부식 접착제에서 높은 미세인장결합강도를 보였다 (p < 0.05). 2. 즉시 및 지연 상아질 봉쇄그룹 모두 미세인장결합강도는 3단계 산 부식, 2단계 자가 부식, 1단계 자가 부식 접착제순으로 감소하였고, 즉시 상아질 봉쇄그룹에서는 1단계 자가 부식 접착제와 다른 소그룹간 유의한 차이가 있었으며 (p< 0.05), 지연 상아질 봉쇄 그룹에서는 모든 소그룹간 유의한 차이가 있었다 (p < 0.05). 3. 파절 양상은 대부분 혼합성 파절을 보였으며, 1단계 자가 부식 접착제에서만 접착성 파절을 보였다.