• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.025 seconds

Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.69-76
    • /
    • 2014
  • Objective: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods: Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of interexaminer and inter-method variability. Results: The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions: The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

Predictability of simultaneous implant placement with sinus floor elevation in the severely atrophic posterior maxillae ; Comparison of lateral and trans-crestal approaches (지상보수교육강좌 1 - 상악동저 거상술을 동반한 임프란트 동시 식립의 예지성 평가; 측방접근술과 치조정접근술의 비교)

  • Kim, Yeong-Wook;Keum, Yoon-Seon;Son, Hyo-Jeong;Lee, Jang-Yeol;Kim, Hyoun-Chull;Lee, Sang-Chull
    • The Journal of the Korean dental association
    • /
    • v.48 no.3
    • /
    • pp.205-217
    • /
    • 2010
  • Purpose The aim of this study is to evaluate the survival rates and analyze the stability of lateral approach and trans-crestal approach for maxillary sinus floor elevation of simultaneous implant placement. Materials and method 407 patients who have been treated in LivingWell dental hospital between 2003 to 2009 were selected. Lateral window technique, osteotome technique and sinus drill technique were used for sinus floor elevation procedure. A total of 714 implants-MP-1 HA coated implant(Tapered Screw $Vent^{TM}$, $Spline^{TM}$, Zimmer, USA), FBR surfaced implant(Pitt-$Easy^{TM}$, Oraltronics, Germany)-were placed in grafted maxillary sinus simultaneously. The autogenous bone or a combination with the allograft or alloplast was grafted into sinus. Sinus floor elevation was combined with vertical/horizontal onlay bone grafts to reconstruct the defect of alveolar ridge. Results The average preoperative height of the maxillary alveolar bone was 5.78mm(range: 0.4mm~12.5mm). 14 implants failed during the healing period(lateral approach: 4, trans-crestal approach: 10) and 3 implant failed after prosthetic loading(lateral approach: 2, trans-crestal approach: 1). The cumulative survival rate of implants after 6 years was 97.6%. Trans-crestal approach(97.4%) and lateral approach(97.9%) had similar survival rates. Conclusion The results indicate that the trans-crestal approach and lateral approach for maxillary sinus elevation is a acceptable method at atrophic maxillary posterior area.

Submental intubation: alternative short-term airway management in maxillofacial trauma

  • Kumar, Ravi Raja;Vyloppilli, Suresh;Sayd, Shermil;Thangavelu, Annamala;Joseph, Benny;Ahsan, Auswaf
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.3
    • /
    • pp.151-156
    • /
    • 2016
  • Objectives: To assess submental route intubation as an alternative technique to a tracheostomy in the management of the airway in cranio-maxillofacial trauma, along with an assessment of its morbidity and complications. Materials and Methods: Submental intubation was performed in 17 patients who had maxillofacial panfacial trauma and management was done under general anesthesia during a period of one year from 2013 to 2014 at Departments of Oral and Maxillofacial Surgery and Dentistry, the Malankara Orthodox Syrian Church Medical College, Kochi, India. Results: In all 17 cases, the technique of submental intubation was found to be simple and reliable. Hypertrophic scars were noted in three cases, orocutaneous fistula and mucocele in one case each. All these complications were managed comfortably without significant morbidity to the patient. Conclusion: Submental intubation is a good technique that can be used regularly in the management of the airway in cranio-maxillofacial trauma, but with some manageable complications.

A Surface Treatment Technique for Interim Crown Fabricated by Three-Dimensional Printing with Digital Light-Processing Technology

  • Son, Keunbada;Lee, Jaesik;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.79-89
    • /
    • 2021
  • Purpose: The technique introduced in this study describes a technique for surface treatment that applies a photocuring resin to the surface of an interim crown fabricated by three-dimensional (3D) printing without a conventional polishing method. The purpose of this study was to evaluate marginal and internal fit and the intaglio surface trueness of interim crowns after surface treatment of 3D-printed crowns for clinical application. Materials and Methods: An interim crown was fabricated using a 3D printer with digital light-processing technology, and the surface support was removed. After the posttreatment process, the resin was thinly applied to the surface of the interim crown and polymerized to solve the esthetic problem of the surface without the conventional polishing process. In addition, the marginal and internal fits were measured to verify the clinical use of this technique, and the trueness was evaluated to confirm the deformation of the inner surface according to the technical application of the outer surface of the interim crown. The difference before and after the evaluation by a statistical method was verified using an independent t-test (α=0.05). Result: There was no significant difference in the marginal and internal fit before and after the application of this technique (P>0.05). There was no significant difference in intaglio surface trueness before and after the application of this technique (P=0.963). Conclusion: There was no change in the marginal and internal fit or in intaglio surface trueness of the interim crowns to which this technology was applied. This surface treatment technique is a more convenient method for interim crowns fabricated using 3D-printing technology without the conventional polishing process.

Segmented Arch Technique 에 의한 최신교정치료법(II)

  • Park, Yeong-Cheol
    • The Journal of the Korean dental association
    • /
    • v.24 no.7 s.206
    • /
    • pp.593-603
    • /
    • 1986
  • Segmented Arch technique은 edgewise mechanics의 한 줄기로서, 미국 코네티컬 주립대학 교정과 과장인 Dr. Burstone에 의하여서 1950년대 이래로 꾸준히 개발되어온 생역학적인 개념(biomechanical concept)을 가장 효율적으로 치료에 적용하고자 함에 있다고 하겠다. 저자는 Segmented arch technique의 최근의 경향과 치료이론 및 술식을 다음의 순서로 4회에 걸쳐서 소개하고자 한다. 1. 전치의 Intrusion에 의한 과개교합의 치료법 -Deep Overbite Correction 2. Space closure - 수평방향의 치아이동방법 3. Root movement의 방법 - Torque mechanics 4. 구치를 Upright 시키는 방법 - Tip back mechanics.

  • PDF

Segmented Arch Technique에 의한 최신교정치료법(III)

  • Park, Yeong-Cheol
    • The Journal of the Korean dental association
    • /
    • v.24 no.8 s.207
    • /
    • pp.698-702
    • /
    • 1986
  • Segmented Arch technique 은 edgewise mechanics의 한 줄기로서, 미국 코네티컬 주립대학 교정과 과장인 Dr. Burstone에 의하여 1950년대 이래로 꾸준히 개발되어온 치료술식으로서 그 특징을 한마디로 요약하면 생역학적인 개념(biomechanical concept)을 가장 효율적으로 치료에 적용하고자 함에 있다고 하겠다. 저자는 Segmented arch technique의 최근의 경향과 치료이론 및 술식을 다음의 순서로 4회에 걸쳐서 소개하고자 한다. 1. 전치의 Intrusion에 의한 과개교합의 치료법 -Deep Overbite Correction 2. Space closure - 수평방향의 치아이동방법 3. 치근의 이동방법 - Root movement 4. 구치를 Upright 시키는 방법 - Tip back mechanics

  • PDF

Segmented Arch Technique에 의한 최신교정방법IV.(완)

  • Park, Yeong-Cheol
    • The Journal of the Korean dental association
    • /
    • v.24 no.10 s.209
    • /
    • pp.870-876
    • /
    • 1986
  • Segmented Arch technique 은 edgewise mechanics의 한 줄기로서, 미국 코네티컬 주립대학 교정과 과장인 Dr. Burstone에 의하여 1950년대 이래로 꾸준히 개발되어온 치료술식으로서 그 특징을 한마디로 요약하면 생역학적인 개념(biomechanical concept)을 가장 효율적으로 치료에 적용하고자 함에 있다고 하겠다. 저자는 Segmented arch technique의 최근의 경향과 치료이론 및 술식을 다음의 순서로 4회에 걸쳐서 소개하고자 한다. 1. 전치의 Intrusion에 의한 과개교합의 치료법 -Deep Overbite Correction 2. Space closure - 수평방향의 치아이동방법 3. 치근의 이동방법 - Root movement 4. 구치를 Upright 시키는 방법 - Tip back mechanics

  • PDF

Implant impression using closed mouth impression technique: a case report (폐구인상채득법을 이용한 임플란트 인상채득 증례)

  • Kim, So-Yeun;Kim, Joo-Hyeun;Jung, Kyoung-Hwa;Jeon, Hye-Mi;Kang, Eun-Sook;Yun, Mi-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.223-229
    • /
    • 2017
  • Closed mouth impression technique by using bite tray is preferred for single tooth impression taking. However, for implant impression taking, open mouth impression technique by using single arch tray is generally used whether it is for single implant or multiple implant. Closed mouth impression technique by using bite tray can save time and materials. It also decreases the chance of error occurrence when a model is mounted on an articulator. In this case report, we tried to show a satisfying result of fabricating single implant fixed prosthodontics after bite tray impression taking by using two different copings for closed mouth impression.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.