• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.027 seconds

Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner (임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용)

  • Park, Ji-Manm;Park, Eun-Jin;Heo, Seong-Joo
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

Surface and Optical Characteristics of Cobalt Dopped-titanium Oxide Film Fabricated by Water Spray Pyrolysis Technique (습식 분무 열분해 방법으로 제조한 코발트 도핑된 티타늄 산화막의 표면 및 광학적 특성)

  • Song Ho-Jun;Park Yeong-Joon
    • Korean Journal of Materials Research
    • /
    • v.15 no.3
    • /
    • pp.209-215
    • /
    • 2005
  • Titanium dioxide films $(TiO_2)$ doped cobalt transition metal were prepared on titanium metal by water spray pyrolysis technique. Micro-morphology, crystalline structure, chemical composition and binding state of sample groups were evaluated using field emission scanning microscope(FE-SEM), X-ray diffractometer(XRD), Raman spectrometer, X-ray photoelectron spectrometer(XPS). $TiO_2$ films of rutile structure were predominately formed on all sample groups and $Ti_2O_3$ oxide was coexisted on the surface of cobalt doped-sample groups. The optical absorption peaks measured by using UV-VIS-NIR spectrophotometer were observed at specific wavelength region in sample groups doped cobalt ion. This result could be analyzed by introducing crystal field theory.

Mucosal dehiscence coverage for dental implant using sprit pouch technique: a two-stage approach

  • Hidaka, Toyohiko;Ueno, Daisuke
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.105-109
    • /
    • 2012
  • Purpose: Soft tissue recessions frequently cause esthetic disharmony and dissatisfaction. Compared with soft tissue coverage around a tooth, the coverage of an implant site is obviously unpredictable. Particularly in the cases of thin mucosa, a significant greater amount of recession takes place compared to thick mucosa. To overcome this problem, this case report demonstrates a two-step mucosal dehiscence coverage technique for an endosseous implant. Methods: A 33-year-old female visited us with the chief complaint of dissatisfaction with the esthetics of an exposed implant in the maxillary left cental incisor region. A partial-thickness pouch was constructed around the dehiscence. A subepithelial connective tissue graft was positioned in the apical site of the implant and covered by a mucosal flap with normal tension. At 12 months after surgery, the recipient site was partially covered by keratinized mucosa. However, the buccal interdental papilla between implant on maxillary left central incisor region and adjacent lateral incisor was concave in shape. To resolve the mucosal recession after the first graft, a second graft was performed with the same technique. Results: An esthetically satisfactory result was achieved and the marginal soft tissue level was stable 9 months after the second graft. Conclusions: The second graft was able to resolve the mucosal recession after first graft. This two-step approach has the potential to improve the certainty of esthetic results.

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

Clinical and biological analysis in graftless maxillary sinus lift

  • Parra, Marcelo;Olate, Sergio;Cantin, Mario
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.4
    • /
    • pp.214-220
    • /
    • 2017
  • Maxillary sinus lift for dental implant installation is a well-known and versatile technique; new techniques are presented based on the physiology of intrasinus bone repair. The aim of this review was to determine the status of graftless maxillary sinus lift and analyze its foundations and results. A search was conducted of the literature between 1995 and 2015 in the Medline, ScienceDirect, and SciELO databases using the keywords "maxillary sinus lift," "blood clot," "graftless maxillary sinus augmentation," and "dental implant placement." Ten articles were selected for our analysis of this technique and its results. Despite the limited information, cases that were followed for at least six months and up to four years had a 90% success rate. Published techniques included a lateral window, elevation of the sinus membrane, drilling and dental implant installation, descent of the membrane with variations in the installation of the lateral wall access and suturing. The physiology behind this new bone formation response and the results of the present research were also discussed. We concluded that this is a promising and viable technique under certain inclusion criteria.

Analysis of the effects of capstone design class utilizing the design thinking technique of class satisfaction of college students (디자인씽킹 기법을 활용한 캡스톤디자인 수업이 대학생의 수업 만족도에 미치는 효과 분석)

  • Lee, Seung Hee;Jung, Hyo Kyung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.394-401
    • /
    • 2020
  • Purpose: The present study is an analysis of the extents of class satisfaction of college students who had applied the design thinking technique to capstone design class. Methods: The experimental method involved an analysis of 122 cases of data where advance and post replies were performed for the subject by students who had applied the design thinking technique and students who had not. The students involved had attended the capstone design class as a junior in the Department of Dental Technology at D University. Results: In the satisfaction with performance process of the capstone design class, five questions among nine had a high positive rating, while all eight questions on the satisfaction with performance methods had a high negative rating. Among ten questions on subjective learning outcomes, six showed a high positive rating. After the application of the design thinking class method, all mean values of the group with the application were higher than the group with no application in satisfaction with performance process, satisfaction with performance method, and subjective class outcomes. Hence, the design thinking class did have positive effects on the students' improvement of class. Conclusion: Based on the results of the study, it is implied that the considerations about diverse class composition methods and operation methods capable of improving the students' satisfaction are needed for efficient operation of the capstone design class.

A hollow definitive obturator fabrication technique for management of partial maxillectomy

  • Patil, Pravinkumar Gajanan;Patil, Smita Pravinkumar
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.248-253
    • /
    • 2012
  • Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM (Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도)

  • Kim, Bong-Chul;Lee, Chae-Eun;Park, Won-Se;Kang, Jeong-Wan;Yi, Choong-Kook;Lee, Sang-Hwy
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

Comparative evaluation of efficacy of external vibrating device and counterstimulation on child's dental anxiety and pain perception during local anesthetic administration: a clinical trial

  • Sahithi, Varada;Saikiran, Kanamarlapudi Venkata;Nunna, Mahesh;Elicherla, Sainath Reddy;Challa, Ramasubba Reddy;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.345-355
    • /
    • 2021
  • Background: This study aimed to evaluate the efficacy of external vibrating devices and counterstimulation on a child's dental anxiety, apprehension, and pain perception during local anesthetic administration. Methods: This was a prospective, randomized, parallel-arm, single-blinded interventional, clinical trial. One hundred children aged 4-11 years, requiring pulp therapy or extraction under local anesthesia (LA), were recruited and allocated equally into two groups (1:1) based on the interventions used: Group BD (n = 50) received vibration using a Buzzy® device {MMJ Labs, Atlanta, GE, USA} as a behavior guidance technique; Group CS (n = 50) received counterstimulation for the same technique. Anxiety levels [Venham's Clinical Anxiety Rating Scale (VCARS), Venham Picture Test (VPT), Pulse oximeter {Gibson, Fingertip Pulse Oximeter}, Beijing, China)] were assessed before, during, and after LA administration, while pain perception [Wong-Baker Faces Pain Rating Scale (WBFPS), Visual Analogue Scale (VAS)] was evaluated immediately after injection. Statistical analysis was performed using the Student's t-test to assess the mean difference between the two groups and the repeated measures ANOVA for testing the mean difference in the pulse rates. Statistical significance was set at P < 0.05. Results: Significant differences in mean pulse rate values were observed in both groups. In contrast, the children in the BD group had higher diminution (P < 0.05), whereas the mean VCARS and VPT scores were conspicuous (P < 0.05). Based on the mean WBFPS and VAS scores, delayed pain perception after LA injection was more prominent in the BD group than in the CS group. Conclusion: External vibration using a Buzzy® device is comparatively better than counterstimulation in alleviating needle-associated anxiety in children requiring extraction and pulpectomy.

Edema and hematoma after local anesthesia via posterior superior alveolar nerve block: a case report

  • Marques, Aline Louise Nascimento;Figueroba, Sidney R.;Mafra, Marco Antonio Tridapalli;Groppo, Francisco Carlos
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.3
    • /
    • pp.227-231
    • /
    • 2022
  • Although rare, complications can occur with anesthetic procedures. The posterior superior alveolar nerve (PSAN) block anesthetic technique has a high success rate, but positive aspiration can cause bruising, transient diplopia, blurred vision, and temporary blindness in approximately 3% cases. When edema occurs, it is occasionally massive, especially in the infratemporal fossa, and the resulting hematoma is usually unsightly. A 20-year-old woman presented with massive edema followed by hematoma in the upper right jaw immediately after PSAN block administration, which subsequently spread to the oral mucosa. The patient did not report any complications during the anesthetic procedure. However, after the injection was administered, the patient experienced anesthetic sensations, which rapidly evolved to facial edema. There was mild pain, but without intraoral or extraoral bleeding. The patient was prescribed medicines and instructed to perform contrast therapy. Although hematomas and edema are rare, they are difficult to prevent. The choice of local anesthetic and appropriate application of the anesthetic technique can minimize their occurrence.