• 제목/요약/키워드: Dental technique

검색결과 1,116건 처리시간 0.027초

A novel technique of submandibular intubation with a camera cable drape: a case report

  • Yun, Hye Joo;Rhee, Seung-Hyun;Park, Joo-Young;Chae, Yeon Su;Han, Jin-Hee;Ryoo, Seung-Hwa;Seo, Kwang-Suk;Kim, Hyun Jeong;Karm, Myong-Hwan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권3호
    • /
    • pp.155-160
    • /
    • 2020
  • Submental or submandibular intubation has been reported to cause fewer complications than tracheostomy. However, the risk of infection is always inherent because oral wounds are exposed to microbial flora and bacteria in the oral cavity. A novel technique of submandibular intubation was devised to reduce infection and injury to the soft tissues. We would like to report a novel safe technique that can be performed in patients requiring submental or submandibular intubation. This is the first report of submandibular intubation using a sterile disposable camera cable drape. This novel technique of submandibular intubation is safer, more sterile, easier, and less invasive than conventional submandibular intubation.

전부도재관 기법 개선에 관한 연구 (A Study on improvements in manufatured technique of all Ceramic Crown)

  • 신무학;김연수;최운재;정희선
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.9-15
    • /
    • 2002
  • A new kind of 'All Ceramic Crown' could be manufactured by making improvements in the manufacturing technique for the current 'All Ceramic Crown' which does not use a special ceramic but rather a general one as a substitute. If we use the manufacturing technique for the 'All Ceramic Crown', metal coping and core are not produced. The effects of the new manufacturing technique for the 'All Ceramic Crown' are as follows: First. We do not need to use new material or special machinery or tools. Second. We can use general machinery and tools. Third. Using the basic 'All Ceramic Technique', we anticipate improvement in learning in our students. Forth. We can save effort, materials and time. Fifth. The technique also has advantages for esthetic 'temporary crown'.

  • PDF

Multispectral X-ray imaging to distinguish among dental materials

  • Peter, Ann-Christin;Schnaubelt, Matthias;Gente, Michael
    • Imaging Science in Dentistry
    • /
    • 제47권4호
    • /
    • pp.247-254
    • /
    • 2017
  • Purpose: Dual-energy X-ray imaging is widely used today in various areas of medicine and in other applications. However, no similar technique exists for dental applications. In this study, we propose a dual-energy technique for dental diagnoses based on voltage-switching. Materials and Methods: The method presented in this study allowed different groups of materials to be classified based on atomic number, thereby enabling two-dimensional images to be colorized. Computer simulations showed the feasibility of this approach. Using a number of different samples with typical biologic and synthetic dental materials, the technique was applied to radiographs acquired with a commercially available dental X-ray unit. Results: This technique provided a novel visual representation of the intraoral environment in three colors, and is of diagnostic value when compared to state-of-the-art grayscale images, since the oral cavity often contains multiple permanent foreign materials. Conclusion: This work developed a technique for two-dimensional dual-energy imaging in the context of dental applications and showed its feasibility with a commercial dental X-ray unit in simulation and experimental studies.

치위생과 학생의 치근단 촬영법 인식에 관한 조사 연구 (A survey study on recognition of periapical radiography in dental hygiene students)

  • 박일순;정정옥;이경희
    • 한국치위생학회지
    • /
    • 제12권5호
    • /
    • pp.987-997
    • /
    • 2012
  • Objectives : This study was carried out in order to obtain basic data for students' efficient acquirement and instruction of radiography technology in the future by surveying dental hygiene students' recognition of periapical radiography. Methods : This study carried out a questionnaire survey targeting dental hygiene students from December 2009 to December 2010, and obtained the following results. Results : 1. As a result of examining recognition on periapical radiography, the bisecting angle technique was indicated to be averagely $3.84{\pm}0.566$ points. The paralleling technique was indicated to be $2.66{\pm}0.701$ points. 2. As a result of examining about problems given the bisecting angle technique, what had been most difficult given the bisecting angle technique was indicated to be the highest in cone positioning with 34.2%. The most difficulty given deciding on the X-ray vertical-angel irradiation direction was indicated to be the highest with 66.9% in adjusting the cone direction on the virtual bisector. 3. As a result of examining about problems given the paralleling technique, what had been most difficult in the process of the paralleling technique was indicated to be the highest with 56.7% in fixing the film immobilization device inside the mouth. Conclusions : Examining the above results, it is considered that there is a need of understanding morphological and anatomical structure inside the mouth in order to reduce the mistake rate given the periapical radiography, and that it is important to increase skill level by repetitively shooting several times with having enough time.

Extraoral periapical radiography: an alternative approach to intraoral periapical radiography

  • Kumar, Rahul;Khambete, Neha;Priya, Ekta
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.161-165
    • /
    • 2011
  • It is difficult to take intraoral radiographs in some patients who are intolerable to place the film in their mouth. For these patients, Newman and Friedman recommended a new technique of extraoral film placement. Here we report various cases that diagnostic imaging was performed in patients using the extraoral periapical technique. This technique was used to obtain the radiographs for the patients with severe gag reflex, pediatric dental patients, and patients with restricted mouth opening. This technique can be recommended as an alternative to conventional intraoral periapical technique in cases where intraoral film placement is difficult to achieve.

Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique

  • Dimitriadis, Konstantinos;Spyropoulos, Konstantinos;Papadopoulos, Triantafillos
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2018
  • PURPOSE. The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS. Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 9693. Another ten substrates were fabricated with a casing dental Co-Cr alloy using classic casting technique (control group) for comparison. Another three substrates were fabricated using each technique to record the Modulus of Elasticity (E) of the used alloys. All substrates were examined to record external and internal porosity. Feldspathic porcelain was applied on the substrates. Specimens were tested using the three-point bending test. The failure mode was determined using optical and scanning electron microscopy. The statistical analysis was performed using t-test. RESULTS. Substrates prepared using DMLS technique did not show internal porosity as compared to those produced using the casting technique. The E of control and test group was $222{\pm}5.13GPa$ and $227{\pm}3GPa$, respectively. The bond strength was $51.87{\pm}7.50MPa$ for test group and $54.60{\pm}6.20MPa$ for control group. No statistically significant differences between the two groups were recorded. The mode of failure was mainly cohesive for all specimens. CONCLUSION. Specimens produced by the DMLS technique cover the lowest acceptable metal-ceramic bond strength of 25 MPa specified in ISO 9693 and present satisfactory bond strength for clinical use.

Effectiveness of dental implantation with the partial split-flap technique on vertical guided bone regeneration: a retrospective study

  • Cho, Young-Dan;Kim, Sungtae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제51권6호
    • /
    • pp.433-443
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effectiveness of the partial split-flap technique with a K-incision on vertical guided bone regeneration (vGBR) and to retrospectively analyze the clinical and radiographic outcomes of dental implantation using this approach. Methods: In total, 78 patients who received 104 dental implants with vGBR, categorized as (1) pre-GBR and post-implantation and (2) simultaneous GBR and implantation, were enrolled. Data analysis was based on periapical radiographs, clinical photos, and dental records. The 2-sample t-test was used to compare the 2 surgical procedures. Results: The baseline vertical bone level, augmented bone height (ABH), and treatment duration were significantly higher in the pre-GBR procedure group. The survival rates of the implants were 96.1% and 94.8% in implant- and patient-based analyses, respectively. In Cox regression analysis, high rates of implant failure were found in the presence of ABH of ≥4 mm, smoking, and diabetes. Conclusions: Within the limitations of this retrospective study, the partial split-flap technique using a K-incision for vGBR showed stable clinical outcomes and favorable dental implant survival.

총의치의 자연스러운 치은형성법에 관한 연구 (A Study on Improving Techniques of Festooning for Denture Base)

  • 신무학;김연수;최운재;정희선
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.103-109
    • /
    • 2003
  • The purpose of this study is to ensure natural restoration of gingiva's form by making effective use of materials in a bid to improve the technique of festooning for denture base. 1. The improved technique is expected to prevent the degradation and deformation of cavity structure and restore it. 2. The improved technique is expected to prevent the change of facial appearance from esthetic viewpoint and restore it. 3. The improved technique is expected to impress again the deformed part on wax denture for additional festooning.

  • PDF

A root submergence technique for pontic site development in fixed dental prostheses in the maxillary anterior esthetic zone

  • Choi, Sunyoung;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Cheong, Chan Wook;Han, Jung-Suk
    • Journal of Periodontal and Implant Science
    • /
    • 제45권4호
    • /
    • pp.152-155
    • /
    • 2015
  • Purpose: This case report discusses the effect of a root submergence technique on preserving the periodontal tissue at the pontic site of fixed dental prostheses in the maxillary anterior aesthetic zone. Methods: Teeth with less than ideal structural support for fixed retainer abutments were decoronated at the crestal bone level. After soft tissue closure, the final fixed dental prostheses were placed with the pontics over the submerged root area. Radiographic and clinical observations at the pontic sites were documented. Results: The submerged roots at the pontic sites preserved the surrounding periodontium without any periapical pathology. The gingival contour at the pontic site was maintained in harmony with those of the adjacent teeth, as well as the overall form of the arch. Conclusions: The results of this clinical report indicate that a root submergence technique can be successfully applied in pontic site development with fixed dental prostheses, especially in the maxillary anterior esthetic zone.