• 제목/요약/키워드: Dental restoration

검색결과 870건 처리시간 0.027초

Microhybrid versus nanofill composite in combination with a three step etch and rinse adhesive in occlusal cavities: five year results

  • Tuncer, Safa;Demirci, Mustafa;Oztas, Evren;Tekce, Neslihan;Uysal, Omer
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.253-263
    • /
    • 2017
  • Objectives: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. Materials and Methods: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. Results: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. Conclusions: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.

전악 발치 환자에서 캠퍼그나 트레이를 적용한 즉시의치 수복 증례 (Fabrication of immediate complete denture using Campagna tray technique)

  • 김남훈;김종은;오경철;정문규;문홍석
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.331-335
    • /
    • 2017
  • 잔존 자연치의 발치가 필요한 환자에서 즉시의치의 제작을 고려해 볼 수 있다. 즉시의치를 장착함으로써 환자가 무치악으로 지내는 기간 없이 심미 및 기능을 회복해줄 수 있는 장점이 있지만 인상 채득이 어렵다는 점, 장착 후의 결과를 예측하기 어렵다는 단점이 있다. 본 증례에서는 잔존 자연치를 모두 발치해야 하는 49세 남환에서 캠퍼그나 트레이를 이용하여 최종 인상을 채득하고 수술용 형판을 이용하여 발치 및 치조골 성형술을 시행한 후, 즉시의치를 제작 및 장착하여 심미적, 기능적으로 만족할 만한 치료 결과를 보였기에 이를 보고하고자 한다.

글레이징처리한 도재와 연마한 도재의 표면조도에 관한 연구 (A STUDY ON THE SURFACE ROUGHNESS OF GLAZED PORCELAIN AND POLISHED PORCELAIN)

  • 최미라;정헌영;이선형;양재호
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.549-565
    • /
    • 1998
  • Porcelain is considered to be one of the materials of choice for restoration where esthetics is of concern. But porcelain surface without final glazing treatment may induce undesirable results such as inflammatory response on adjacent soft tissues due to plaque accumulation and increased wear of opposing teeth. Therefore, rough porcelain surface must be smoothened by final glazing treatment or chairside polishing procedure. The purpose of this study was to compare the surface roughness among self-glazed, overglazed and polished porcelain with various polishing kit, and to detect which phase of polishing is optimal in clinic. Specimens were fabricated with Vita VMK porcelain. The surface treatment of each group was performed as follows. Group 1 : overglazing treatment Group 2 : self-glazing treatment Group 3 : polishing with the Truluster Polishing System for Porcelain(Brasseler, U.S.A.) Group 4 : polishing with the Exa Cerapol Adjustment kit (Edenta dental products, Switzerland) followed by finishing with diamond-filled polishing paste Group 5 : polishing with the Shofu Porcelain Adjustment kit (Shofu inc., Japan) followed by finishing with diamond-filled polishing paste. At each polishing steps, the measurement of Ra and Rq values were performed, and the surface was examined by scanning electron microscope. The results were as follows : 1. Overglazing treatment brought smoother surface than self-glazing treatment. 2. Polishing systems without porcelain polishing paste did not make better result than self-glazing treatment. 3. Polishing system with porcelain polishing paste made similar result to overglazing treatment. 4. Applying diamond-filled polishing paste after using polishing system which has no porcelain polishing paste produced surface as smooth as overglazing treatment does.

  • PDF

치아전위의 임상적 고찰 (A CLINICAL CONSIDERATION ON THE TEETH TRANSPOSITIONS)

  • 김승미;정태성;김신
    • 대한소아치과학회지
    • /
    • 제26권1호
    • /
    • pp.38-43
    • /
    • 1999
  • 치아전위는 비교적 드문 발육장애이다. 적절하게 차단치료된다면 예방이 가능할 뿐 아니라 이후의 교정과 수복과정이 보다 용이할 수 있다. 이를 위한 8-9세 경의 조기 임상검사가 이러한 발육장애의 인지를 위해 추천된다. 일단 전위가 일어난 경우에는, 부정교합을 교정하고 최상의 기능적, 심미적 결과를 얻기 위해 주의깊은 교정적 평가가 요구된다. 이상적인 결과를 얻기 위하여 두 치아를 원래의 위치로 환원시키는 치료가 요구되나, 완전전위되어 두 치아가 맹출되었다면 전위된 상태로 치아를 배열하여도 비교적 양호한 결과를 얻을 수 있었다.

  • PDF

수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구 (A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW)

  • 김진만;한중석;이선형;양재호;이재봉;김영수
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.

자가치아 뼈 이식재의 유용성에 관한 임상적 연구 (Clinical Study on the Efficacy of the Autogenous Tooth Bone Graft Material (AutoBT))

  • 한민우;이정근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권4호
    • /
    • pp.221-226
    • /
    • 2013
  • Purpose: This study is to evaluate the efficacy of the autogenous tooth bone graft material, clinically and radiologically, as related to implant installation. Methods: In oral and maxillofacial surgery department of Ajou University Hospital, guided bone regeneration (GBR), implant placement combined with GBR, sinus graft, implant placement combined with sinus graft, and defect filling were performed in 46 patients, using autogenous tooth bone. Among these, 66 implants were inserted with autogenous tooth bone. Implant stability quotient (ISQ) was measured by Osstell Mentor (Integration Diagnostics, Goteborg, Sweden) on 39 implants on the operation date and 4 months later, and on 21 implants 9months on the average at the final setting of restoration. Twenty-eight implants with GBR and sinus graft (GBR group: n=14, sinus graft group: n=14) were evaluated radiologically to measure the resorption of grafted autogenous tooth bone after loading. Results: The average initial stabilization of the installed implants was 67 ISQ, and the average secondary stabilization at 4 months later was 76. The average bone loss of GBR group as measured 8.0 months after application of prosthesis loading was 0.29 mm and the average bone loss of the sinus graft group as measured 7.6 months after application of prosthesis loading was 0.66 mm, respectively. In the histological assessment, formation of the new bone and continuous trabecular bone pattern was identified around autogenous tooth bone. Conclusion: Based on these results, we concluded that autogenous tooth bone is an excellent bone graft material that can substitute the autogenous bone.

비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향 (OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS)

  • 김성원;조인호;임주환;임헌송
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

심한 마모를 가진 환자에서 임플란트와 가철성 국소의치를 이용한 전악수복 증례 (Full mouth rehabilitation of severely worn dentition with implants and removable partial dentures)

  • 이신언;이원섭;이철원;이수영
    • 대한치과보철학회지
    • /
    • 제56권1호
    • /
    • pp.70-76
    • /
    • 2018
  • 과도한 치아 마모는 수직 고경 감소를 초래하고 구강 환경과 저작계의 병적 변화를 유발할 수 있다. 수직 고경과 교합을 회복시켜주기 위해서는 정확한 진단과 분석이 필수적이다. 본 증례에서는, 75세 여성환자로 구치부 지지 상실로 인한 치아 심한 마모가 관찰되었다. 따라서 수직 고경 거상을 동반한 전악 재건 수복을 계획하였다. 정확한 임상적 방사선학적 검사, 수직 고경 평가 후 진단 납형을 제작하였고 임시보철수복을 통해 환자의 적응여부를 평가하였다. 최종 수복은 환자의 경제적 상황을 고려하여 가철성 국소의치를 제작하였으며 하악 좌우측 구치부에 임플란트를 한 개씩 식립하여 국소의치의 지지와 유지를 보강하였다. 최종 수복물 장착 후 1년 간의 경과관찰 기간 동안 기능적, 심미적으로 만족할 만한 결과를 보였다.

소아에서 다수치아 상실 시 탄성의치 사용의 치험례 (REMOVABLE FLEXIBLE DENTURE FOR CHILD WITH LOSS OF MULTIPLE TEETH : A CASE REPORT)

  • 정양석;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제34권3호
    • /
    • pp.513-518
    • /
    • 2007
  • 소아에서 외상, 다발성 치아 우식증, 전신 질환 등에 의한 다수 치아 상실시 저작력 저하, 영양의 불균형, 부정교합, 심미성의 저하등의 문제점이 발생할 수 있다. 이러한 경우 가철성 의치의 장착으로 저작력 회복, 치열 공간 유지, 심미성 증진 및 정확한 발음의 향상을 도모할 수 있다. 그러나 기존의 Wire와 아크릴릭 레진을 이용한 가철성 장치는 낮은 유지력으로 인해 저작력의 회복에 한계가 있고, wire의 노출로 인해 비심미적이다. 또한 구강내 많은 면적을 피개하는 아크릴릭 레진으로 인해 정확한 발음이 어렵고 저작력이 주로 지대치에만 가해지는 문제점이 있다. 그러나 소아에게 주조 금속 가철성 의치를 적용할 경우 유치에서 undercut을 얻기가 어렵고, 무게로 인해 적응하기가 어렵다. 또한 악골의 횡적인 성장에 방해가 될 수 있고 초기 영구치의 삭제가 필요한 경우도 있다. 이러한 단점을 보완할 수 있는 탄성 의치상재가 1950년도에 개발되었다. 의치상과 유지장치가 일체형으로 연조직의 undercut까지 이용 가능하고 재료 자체의 색조와 투명성으로 심미성이 향상되었다. 또한 얇게 제작 가능하기 때문에 발음의 불편함도 줄일 수 있고, 지대치 이외의 조직으로 저작력의 분산이 가능하여 잔존골의 흡수를 지연시키는데 도움을 준다. 본 증례에서는 여러 증례에서 기존의 가철성 의치의 단점을 보완할 수 있는 탄성 가철성 의치를 이용하여 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF

정중과잉치의 자가이식을 통한 상실된 상악 중절치의 수복 : 증례보고 (RESTORATION OF MISSED MAXILLARY CENTRAL INCISOR USING AUTOTRANSPLANTATION OF MESIODENS : A CASE REPORT)

  • 김혜경;박호원;이주현;서현우
    • 대한소아치과학회지
    • /
    • 제34권3호
    • /
    • pp.519-525
    • /
    • 2007
  • 과잉치는 정상 치판의 과도한 증식의 결과로 발생하고, 주로 상악 전방부에서 많이 발견되며 이것을 정중과잉치라 칭한다. 정중과잉치의 존재 시 영구 전치의 위치 이상, 정중이개, 낭종의 형성, 구강 및 비강 내로의 맹출 등과 같은 다양한 문제가 존재하게 되므로 발거하는 것이 일반적이다. 본 증례는 외상으로 인해 편측 상악 중절치를 조기에 상실하였고, 매복된 상악 정중과잉치를 가지고 있는 9세 8개월된 남아로, 정중과잉치를 상실된 상악 중절치 부위에 자가이식한 후 보철적으로 수복하여 치조골 흡수를 막고 심미적인 수복을 도모한 증례이다. 이 증례에서 과잉치는 총 길이 14mm로 지대치로 사용하기에는 크기가 작고 치관/치근 비율도 좋지 않아 예후가 불량할 것으로 예상하였으나, 시술 후 8개월의 관찰 기간 동안 양호한 결과를 나타내어 이에 보고하는 바이다.

  • PDF