Objectives: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. Materials and Methods: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. Results: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. Conclusions: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.
잔존 자연치의 발치가 필요한 환자에서 즉시의치의 제작을 고려해 볼 수 있다. 즉시의치를 장착함으로써 환자가 무치악으로 지내는 기간 없이 심미 및 기능을 회복해줄 수 있는 장점이 있지만 인상 채득이 어렵다는 점, 장착 후의 결과를 예측하기 어렵다는 단점이 있다. 본 증례에서는 잔존 자연치를 모두 발치해야 하는 49세 남환에서 캠퍼그나 트레이를 이용하여 최종 인상을 채득하고 수술용 형판을 이용하여 발치 및 치조골 성형술을 시행한 후, 즉시의치를 제작 및 장착하여 심미적, 기능적으로 만족할 만한 치료 결과를 보였기에 이를 보고하고자 한다.
Porcelain is considered to be one of the materials of choice for restoration where esthetics is of concern. But porcelain surface without final glazing treatment may induce undesirable results such as inflammatory response on adjacent soft tissues due to plaque accumulation and increased wear of opposing teeth. Therefore, rough porcelain surface must be smoothened by final glazing treatment or chairside polishing procedure. The purpose of this study was to compare the surface roughness among self-glazed, overglazed and polished porcelain with various polishing kit, and to detect which phase of polishing is optimal in clinic. Specimens were fabricated with Vita VMK porcelain. The surface treatment of each group was performed as follows. Group 1 : overglazing treatment Group 2 : self-glazing treatment Group 3 : polishing with the Truluster Polishing System for Porcelain(Brasseler, U.S.A.) Group 4 : polishing with the Exa Cerapol Adjustment kit (Edenta dental products, Switzerland) followed by finishing with diamond-filled polishing paste Group 5 : polishing with the Shofu Porcelain Adjustment kit (Shofu inc., Japan) followed by finishing with diamond-filled polishing paste. At each polishing steps, the measurement of Ra and Rq values were performed, and the surface was examined by scanning electron microscope. The results were as follows : 1. Overglazing treatment brought smoother surface than self-glazing treatment. 2. Polishing systems without porcelain polishing paste did not make better result than self-glazing treatment. 3. Polishing system with porcelain polishing paste made similar result to overglazing treatment. 4. Applying diamond-filled polishing paste after using polishing system which has no porcelain polishing paste produced surface as smooth as overglazing treatment does.
치아전위는 비교적 드문 발육장애이다. 적절하게 차단치료된다면 예방이 가능할 뿐 아니라 이후의 교정과 수복과정이 보다 용이할 수 있다. 이를 위한 8-9세 경의 조기 임상검사가 이러한 발육장애의 인지를 위해 추천된다. 일단 전위가 일어난 경우에는, 부정교합을 교정하고 최상의 기능적, 심미적 결과를 얻기 위해 주의깊은 교정적 평가가 요구된다. 이상적인 결과를 얻기 위하여 두 치아를 원래의 위치로 환원시키는 치료가 요구되나, 완전전위되어 두 치아가 맹출되었다면 전위된 상태로 치아를 배열하여도 비교적 양호한 결과를 얻을 수 있었다.
Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.
Purpose: This study is to evaluate the efficacy of the autogenous tooth bone graft material, clinically and radiologically, as related to implant installation. Methods: In oral and maxillofacial surgery department of Ajou University Hospital, guided bone regeneration (GBR), implant placement combined with GBR, sinus graft, implant placement combined with sinus graft, and defect filling were performed in 46 patients, using autogenous tooth bone. Among these, 66 implants were inserted with autogenous tooth bone. Implant stability quotient (ISQ) was measured by Osstell Mentor (Integration Diagnostics, Goteborg, Sweden) on 39 implants on the operation date and 4 months later, and on 21 implants 9months on the average at the final setting of restoration. Twenty-eight implants with GBR and sinus graft (GBR group: n=14, sinus graft group: n=14) were evaluated radiologically to measure the resorption of grafted autogenous tooth bone after loading. Results: The average initial stabilization of the installed implants was 67 ISQ, and the average secondary stabilization at 4 months later was 76. The average bone loss of GBR group as measured 8.0 months after application of prosthesis loading was 0.29 mm and the average bone loss of the sinus graft group as measured 7.6 months after application of prosthesis loading was 0.66 mm, respectively. In the histological assessment, formation of the new bone and continuous trabecular bone pattern was identified around autogenous tooth bone. Conclusion: Based on these results, we concluded that autogenous tooth bone is an excellent bone graft material that can substitute the autogenous bone.
Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.
과도한 치아 마모는 수직 고경 감소를 초래하고 구강 환경과 저작계의 병적 변화를 유발할 수 있다. 수직 고경과 교합을 회복시켜주기 위해서는 정확한 진단과 분석이 필수적이다. 본 증례에서는, 75세 여성환자로 구치부 지지 상실로 인한 치아 심한 마모가 관찰되었다. 따라서 수직 고경 거상을 동반한 전악 재건 수복을 계획하였다. 정확한 임상적 방사선학적 검사, 수직 고경 평가 후 진단 납형을 제작하였고 임시보철수복을 통해 환자의 적응여부를 평가하였다. 최종 수복은 환자의 경제적 상황을 고려하여 가철성 국소의치를 제작하였으며 하악 좌우측 구치부에 임플란트를 한 개씩 식립하여 국소의치의 지지와 유지를 보강하였다. 최종 수복물 장착 후 1년 간의 경과관찰 기간 동안 기능적, 심미적으로 만족할 만한 결과를 보였다.
소아에서 외상, 다발성 치아 우식증, 전신 질환 등에 의한 다수 치아 상실시 저작력 저하, 영양의 불균형, 부정교합, 심미성의 저하등의 문제점이 발생할 수 있다. 이러한 경우 가철성 의치의 장착으로 저작력 회복, 치열 공간 유지, 심미성 증진 및 정확한 발음의 향상을 도모할 수 있다. 그러나 기존의 Wire와 아크릴릭 레진을 이용한 가철성 장치는 낮은 유지력으로 인해 저작력의 회복에 한계가 있고, wire의 노출로 인해 비심미적이다. 또한 구강내 많은 면적을 피개하는 아크릴릭 레진으로 인해 정확한 발음이 어렵고 저작력이 주로 지대치에만 가해지는 문제점이 있다. 그러나 소아에게 주조 금속 가철성 의치를 적용할 경우 유치에서 undercut을 얻기가 어렵고, 무게로 인해 적응하기가 어렵다. 또한 악골의 횡적인 성장에 방해가 될 수 있고 초기 영구치의 삭제가 필요한 경우도 있다. 이러한 단점을 보완할 수 있는 탄성 의치상재가 1950년도에 개발되었다. 의치상과 유지장치가 일체형으로 연조직의 undercut까지 이용 가능하고 재료 자체의 색조와 투명성으로 심미성이 향상되었다. 또한 얇게 제작 가능하기 때문에 발음의 불편함도 줄일 수 있고, 지대치 이외의 조직으로 저작력의 분산이 가능하여 잔존골의 흡수를 지연시키는데 도움을 준다. 본 증례에서는 여러 증례에서 기존의 가철성 의치의 단점을 보완할 수 있는 탄성 가철성 의치를 이용하여 양호한 결과를 얻었기에 보고하는 바이다.
과잉치는 정상 치판의 과도한 증식의 결과로 발생하고, 주로 상악 전방부에서 많이 발견되며 이것을 정중과잉치라 칭한다. 정중과잉치의 존재 시 영구 전치의 위치 이상, 정중이개, 낭종의 형성, 구강 및 비강 내로의 맹출 등과 같은 다양한 문제가 존재하게 되므로 발거하는 것이 일반적이다. 본 증례는 외상으로 인해 편측 상악 중절치를 조기에 상실하였고, 매복된 상악 정중과잉치를 가지고 있는 9세 8개월된 남아로, 정중과잉치를 상실된 상악 중절치 부위에 자가이식한 후 보철적으로 수복하여 치조골 흡수를 막고 심미적인 수복을 도모한 증례이다. 이 증례에서 과잉치는 총 길이 14mm로 지대치로 사용하기에는 크기가 작고 치관/치근 비율도 좋지 않아 예후가 불량할 것으로 예상하였으나, 시술 후 8개월의 관찰 기간 동안 양호한 결과를 나타내어 이에 보고하는 바이다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.