• Title/Summary/Keyword: Dental prostheses

Search Result 370, Processing Time 0.032 seconds

Splinted and non-splinted implant-supported restorations : prosthetic considerations for restoring multiple adjacent teeth (Splinted or Non-splinted: 다수의 인접한 치아 결손부 수복을 위한 임플란트 보철)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2016
  • The purpose of this paper was to investigate the significance of splinted and non-splinted implant-supported restorations with an internal connection for multiple consecutively missing teeth. Upon examination of the effects of fixture-abutment connection, the distribution of occlusal load was favorable in splinted implant-prosthesis with an external connection, but effect of strain distribution was not significant in splinted implant-prosthesis with an internal connection. In splinted implant-prostheses for short implants, strain distribution was not affected by the method of retention. For cement-retained prostheses, the effect of strain distribution due to splinting was not significant. In clinical studies, non-splinted prostheses with an internal connection for multiple consecutively missing teeth showed high survival rate, mild marginal bone loss, and stable periodontal condition. However, failure to achieve optimal proximal contact between single-unit prostheses may lead to food impaction, and veneer fracture may be inevitable when the framework provides inadequate support in the proximal region. In conclusion, splinted implant-prosthesis is not an indication in all cases, and clinical consideration of its use should be based on the patient's oral condition, such as location and number of implants, formation of proximal contact, canine guidance, existence of parafunctional habit, and oral hygiene, when multiple consecutively missing teeth are replaced by internal connection type implant.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Effect of drill radius setting on prosthesis machining (드릴 반경 설정이 보철물 가공에 미치는 영향)

  • Kim, Chong-Myeong;Kim, So-Ri;Cho, Mi-hyang
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the trueness and fitness of machined prostheses according to drill radius setting in CAD software. Methods: For this study, standard abutment were replicated in Type IV stone. The stone abutment were scanned using a dental scanner. The CAD design software was designed using scanned abutment data. When designing, the drill radius was set to 0.3 mm and 0 mm, respectively, and saved. The saved design data was milled using a milling machine (n=13). The inner surface of the milled crown was scanned. The trueness and fitness were measured using the inner scan data of prostheses. Independent t-tests were performed to identify significant differences in each data. Results: Trueness values of the data saved with 0.3 mm and 0 mm drill radius were $18.9{\pm}2.3{\mu}m$ and $19.1{\pm}0.9{\mu}m$, respectively. There was no statistically significant difference between the groups. Fitness values of the data saved with 0.3 mm and 0 mm drill radius were $65.5{\pm}0.8{\mu}m$ and $33.8{\pm}1.0{\mu}m$, respectively. There was a statistically significant difference between the groups (p<.05). Conclusion : Setting the drill radius is important to produce clinically good fit prostheses.

A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning (하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구)

  • Kim, Woo-Sung;An, Kyung-Mi;Sohn, Dong-Seok;Jung, Heui-Seung;Shin, Im-Hee
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

An Investigation of a Motive for Dental Implant Treatment in Clinical Cases (임플란트 선택동기 및 인지도 조사연구 -울산지역 성인 남, 여를 대상으로-)

  • Lee, Gar-Yeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.237-253
    • /
    • 2004
  • This study was to find a patient's motive for receiving implant treatment by age and gender using a self-reporting questionnaire survey with adults(men & women) in Woolsan. The result was as follows: 1. As a result of questionnaire survey with 155 patients in total(86 men, 69 women), 24 of 86 men(27.9%) valued the natural mastication feature of dental implant most, that is as similar as natural teeth, while 18 of 69 women(26.1%) had the most priority over the longer life of implant than common dental prostheses. By age, those in their 20s and 30s had a preference to implant treatment because it does not need to pulling out teeth for prostheses, while those in their 40s and over had a priority to the natural mastication feature of implant that is similar as much as natural teeth. By dental treatment, all of respondents said that the natural mastication feature is the most important in getting dental implant. It was founded that whether one can taste food as it is or not is less important, regardless of age or gender. 2. The greatest obstacle to implant surgery was expensive medical fees, 88 of 155 respondents(56.8%), with a fear of surgery itself being the least obstacle. 3. 90.2% of the total respondents said that they will want to receive dental implant treatment if their economy allow.

  • PDF

Interproximal contact loss between implant-supported prostheses: a clinical report (임플란트 고정성 보철물 사이에서의 인접면 접촉상실: 증례보고)

  • Yeon-Hee Park;Kyoung-A Kim;Jung-Jin Lee;Jae-Min Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.47-53
    • /
    • 2024
  • Interproximal contact loss (ICL) is the most frequent complication in partially edentulous patients treated with implant-supported prostheses. However, in most cases, ICL occurs between the implant prosthesis and the natural tooth due to the movement of the natural tooth. There are several causes of ICL that occur between an implant prosthesis and a natural tooth. There are only a few reported cases of ICL occurring between implant prostheses, and explaining the causes of ICL between implant prostheses and natural teeth is challenging. This clinical report describes cases of ICL between implant prostheses and discusses its causes and countermeasures.

RADIOGRAGHIC STUDY OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANTS AFTER FUNCTIONAL LOADING (보철물 장착후 골 유착성 임플란트 변연골 소실에 관한 방사선학적 연구)

  • Park, Ki-Hyun;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.806-815
    • /
    • 1998
  • Regular radiographic examination has been considered as an essential diagnostic method for the osseointegrated dental implantation. This study investigated the marginal bone loss through the measurement on the periapical radiograph around 46 endosseous dental implants. Marginal bone loss have been observed for 5 years after delivery of prostheses. The results were as follows : 1. According to the experimental periods, average marginal bone loss in total implant was 1.821mm in the first year, 1.833mm in the second, 1.892mm at third, 1.910mm at forth and 1.957mm at fifth after delivery of prostheses(P<0.05). 2. The average bone loss was 1.832mm in the maxillae and 1.819mm in the mandible in three years but there was no significant difference between the upper and lower jaw(P>0.05). 3. The average bone loss was 1.824mm in males and 1.818mm in females in five years but there was no significant difference according to the sex(P>0.05). These results indicate that the most of the alveolar bone loss occur within the first year after delivery of dental prostheses resulting in the exposure of polished neck positions, and the bone level stabilizes at first thread portion of the implant fixtures.

  • PDF

Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • PURPOSE. The objective of this literature review was to analyze the cumulative survival rates (CSRs) of rigid and non-rigid double-crown-retained removable dental prostheses. MATERIALS AND METHODS. Screening of the literature published from January 1995 to December 2019 was performed by using electronic data base (Pubmed) and manual search. The CSRs of rigid and non-rigid double crown removable dental prostheses were investigated. RESULTS. A total of 403 articles were reviewed and 56 relevant articles of them were selected. Subsequently, 25 articles were included for data extraction. These articles were classified according to rigid and non-rigid type double crowns and further subdivided into teeth, implants, and teeth-implant combination types. The CSRs of rigid type double crown ranged from 68.9% to 95.1% of 5 to 10 years in tooth abutments, 94.02% to 100% over a 3-year mean observation periods in implant abutments, and 81.8% to 97.6% in tooth-implant combination. Non-rigid type double crowns had various CSR ranges from 34% to 94% maximum during 10 years observation in teeth abutment. The CSRs of non-rigid type had over 98% in implant abutments, and ranged from 85% to 100% in tooth-implant combination. CONCLUSION. The CSRs of double crowns varies according to types. With accurate evaluation of the remaining teeth and plan of the strategic implant placement, it could be successful treatment alternatives for partially or completely edentulous patients.

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.

The effects of dental prostheses to the quality of life among the elderly (일부 노인의 치과보철물 상태가 구강건강관련 삶의 질에 미치는 영향)

  • Hur, Ik-Gang;Lee, Tae-Yong;Dong, Jin-Keun;Hong, Song-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.101-110
    • /
    • 2010
  • Purpose: This study has been conducted in order to examine the oral health status and dental prostheses status, and the effects of dental prostheses to the oral health related quality of life among the elderly using social welfare centers. Material and methods: For this purpose, the researcher conducted a questionnaire survey and oral examination of 275 samples of old persons using 7 social welfare centers located in Daejeon metropolitan city. The oral health related quality of life was measured by GOHAI (Geriatric Oral Health Assessment Index). Results: 1. The less age and the more education and the more subjective economic status and living with spouse of family status, the higher GOHAI showed. 2. Mean age of first using of removable denture is 62.11 years old and average life cycle of removable denture is 10.76years. 57.5% of study subjects use removable denture and complete denture user of study subjects are 13.8%. 3. In the case that they use fixed prostheses rather than removable ones and in the complete denture they use both sides (upper and lower) rather than single side, showed higher GOHAI. 4. In the case that they showed higher degrees of satisfaction with dental prostheses and can use them always and showed no necessity for new dental prostheses and denture adaptation is good, GOHAI showed higher. Conclusion: In order to improve oral health related quality of life among the elderly who have many missing teeth, it is required to restore their masticatory ability to the normal level by restoring the missing teeth which has lost its function through providing proper dental prostheses.