• Title/Summary/Keyword: Dental laboratory technology

Search Result 686, Processing Time 0.029 seconds

Evaluation of Physical Properties of Resin Containing Zinc Nanoparticle. (아연나노입자함유 교정용 레진의 물리적 특성 평가)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.373-379
    • /
    • 2019
  • Polymethyl methacrylate (PMMA), a self-polymerizing resin for removable orthodontic devices, has been used as a dental orthodontic device for many years because of its advantages such as color stability, volume stability, and tissue compatibility. However, such a removable orthodontic device has a disadvantage that the longer the use in the oral cavity due to the low strength of the PMMA fracture of the orthodontic device resin in use. In this study, zinc nanoparticles (ZNP) were mixed with orthodontic PMMA to introduce strength effect. Rectangular samples ($1.4{\times}3.0{\times}19.0mm$) of orthodontic PMMA (0, 0.5, 1.0, 2.0 and 4.0%) containing ZNP were prepared. The finished specimen was tested for three-point bending strength at a speed of 1 mm / min, and the Vickers hardness was measured three times using a hardness tester. The surface roughness was measured with a surface roughness. As a result, the 3-point bending strength did not change significantly (p>0.05). Surface energy increased significantly. As a result, we successfully synthesized ZNP in this study and prepared the dispersed resin specimen for calibration. It will be possible to develop high-density dental orthodontic resins.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

The relationship between past smoking period and tooth loss in Korean elderly (한국 노년층의 과거흡연기간과 상실치아의 연관성)

  • Yu, Sang-Hui
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.9-14
    • /
    • 2018
  • The purpose of this study was to evaluate the relationship between past smoking period and tooth loss in Korean elderly based on the data the Sixth Korea National Health and Nutrition Examination Survey (2013-2015). The study subjects were 4,037 elderly people (1,737 men and 2,300 women) over 65 years old. The statistical analyses were conducted by applying complex sample analysis technique using SPSS/WIN 22.0(${\alpha}=0.05$). The average number of tooth loss in Korean elderly was 11.14. The analysis result of the relationship of the tooth loss according to the past smoking period, the risk of tooth loss was more than twice higher in over 30 years past smoking period group than in under 10 years past smoking period group. In conclusion, the long term past smoking were associated with tooth loss in Korean elderly. Therefore, it seems to need a continuous oral health care through non-smoking policy and education.

Using treatment denture and digital technology in patient with unstable mandibular movement: a case report (불안정한 하악위를 가진 무치악 환자에서 치료의치와 디지털 기술을 이용한 치료 증례)

  • Eunji Oh;Woohyung Jang;Chan Park;Kwidug Yun;Hyun-Pil Lim;Sangwon Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.168-175
    • /
    • 2023
  • Long-term use of inappropriate prosthesis often results in habitual closure or irregular mandibular movements. In that case, guide to the stable centric position is difficult. Therefore, by using a treatment denture, the muscles and TMJ should be stabilized and the jaw relation should be acquired with the treatment position. Compared to the conventional method, digital technology in fabrication complete denture has the advantage of reproducing a stable tooth arrangement in cases of difficult tooth alignment, minimizing laboratory errors and reducing denture fabrication time. Therefore, in this case, the final denture was fabricated by digitally reproducing the stable treatment position, vertical dimension, and lip support with a treatment denture, and satisfactory results were obtained.

Effect of coloring agent dryness on zirconia color (치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Hae-Jung;Moon, Yun Hee;Kim, Woong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.176-182
    • /
    • 2018
  • One of the most important factor of esthetic prosthesis is the color of the teeth. Zirconia is produced in the process of design, milling, coloring, drying, and sintering. The effect of the drying degree of zirconia colorant on the color tone is examined. For the experiment, a total of 45 zirconia specimens(15 for each) were fabricated by using cad/cam system. The zirconia specimens(L block(LAZOR), Z block(Zircos-E block posterior), A block(AlphaZ)) were then subjected to zirconia sintering in accordance with the manufacturer's instructions, using a chemical coloring agent to Non-drying(0sec), intermediate (10sec), and completely dried (10min) temperature holding times. The color tone was measured using a spectrophotometer. The results were analyzed with a One-way analysis of variance and the Tukey post-hoc test (${\alpha}=.05$) The $L^*$ values of L, A specimens, $a^*$ values of A specimens, and $b^*$ values of Z specimens were not statistically different according to the degree of drying (p>0.05), While the $L^*$ value of Z specimen, $a^*$ value of L, Z specimen, $b^*$ values of L, A specimens were statistically different according to the degree of drying(p <0.05). In conclusion, the drying of zirconia colourants improves zirconia brightness and increases the optical properties of the enamel.

A Study on the Relationships of Oral Status and Self-perceived Oral Health Status in Elderly (일부 노인의 구강내 상태와 자가인지 구강건강상태와의 관련성)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.145-155
    • /
    • 2013
  • Purpose: The recent proliferation of the aging population, oral health care is closely related to the mental health of the elderly is very important being recognized. Provide basic data for improving the quality of life for the elderly, to determine whether the oral health of the elderly whether oral self-perception of health and any related wish. Methods: Surveys to May 20 from April 15, 2011, subjects were elderly and living in Daejeon and Chungnam 277 people were examined. All the statistics using SPSS 18.0 for the determination of statistical significance, and the significance level was 0.05. Results: 1. Recognized, the most common oral health, self-aware bad the state (46.2%) there was no significant difference in the general characteristics according to self-Oral health status, remaining natural dimensions or the intra-oral prosthetic, there was no significant difference. More teeth, residual phase, in accordance with intra-oral prosthetic mandibular Not all dentures, partial dentures, full dentures net self-perception of oral health status better recognized. 2. According to the type of partial dentures, oral health status self-phase, mixed mandibular removable, fixed, fixed, removable partial dentures in order to recognize that good oral health, self-aware state, showed between them, there was no significant difference. 3. Of variable dimension that has nothing to do with the remaining natural maxillary and mandibular prosthetic maxillary prosthetic mandibular partial dentures, age income, a positive correlation was negatively correlated. The case of the mandible, the mandibular prosthetic mandibular partial denture, maxillary prosthetic, the amount of income were correlated. 4. Intra-oral Prosthetics correlation variables in the maxillary, mandibular prosthesis, the positive correlation between income, age was negatively correlated, if the income of the mandible. Maxillary partial denture has nothing to do with the variable portion of the mandibular denture, age was a negative correlation was found. Conclusion: Satisfaction and how now it is important simply to live as long, but you need to pay attention to the quality of life, sometimes with an aging population and the increase of soybean To buy the loss of teeth causes the typical health problems of the elderly. Elderly people of any relevant oral health and the oral cavity by the state to determine whether to provide the basic data for oral health education was more residual value, intra-oral prosthetics there is no more self-aware, the oral health status is good to recognize that appeared. Strengthen the oral health education to improve the quality of life of the elderly, and is thought to be necessary to increase the number of residual.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Influential factors for the oral health awareness of college students (일부지역 대학생들의 구강보건인식에 영향을 미치는 요인)

  • Noh, Hyeong-Rok;Oh, Han-Na
    • Journal of Digital Convergence
    • /
    • v.12 no.8
    • /
    • pp.431-438
    • /
    • 2014
  • The purpose of this study was to examine the relationship between the self-esteem and oral health awareness of college students and influential factors for their oral health awareness in an effort to plan an oral health program tailored to college students. The subjects in this study were 394 students who were in G college and J university in the city of Gwangju, on whom a self-administered survey was conducted. After a survey was conducted, the collected data were analyzed. The findings of the study were as follows: Regarding oral health awareness by general characteristics, the students who had experience of receiving oral health education were better in that regard(p<0.05). As to awareness of oral health education, the health-related majors took the best view of it (p<0.05). Concerning the links between self-esteem and oral health awareness, there was a significant positive correlation between the two. As a result of analyzing what factors affected oral health awareness, oral health awareness was under the significant influence of self-esteem, self-rated oral health status and oral health education(p<0.05). Given the findings of the study, oral health education programs geared toward college students should be developed in consideration of the various influential factors for oral health awareness to offer better education.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

Development of Organic Paste Porcelain for Fixed Prostheses (유기조성물을 이용한 페이스트형 일반도재 시스템)

  • Han, Jung-Suk;Lee, Myung-Hyun;Kim, Dae-Hyun;Chung, Hun-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.109-120
    • /
    • 2004
  • INTRODUCTION: The build-up method has been used for application of porcelain powder on the metal framework to make final tooth shape conventionally. This method takes time and need skill to mimic final shade and shape of porcelain fused to metal crown. The purpose of this study was to develop standard shape and shade laminating porcelain forms to reduce build-up time. METHODS: To make tooth form porcelain paste, several liquid organic compounds were added to conventional feldspathic porcelain. The amount of additives and rheologic property were tested to find out best composition. Comparison of mixing methods to reduced porosity, proper heating schedule, and measurement of shrinkage amount and residual organic materials were performed to set-up standard procedures. Finally, biaxial flexural strength and color of preformed laminated paste porcelain were compared with those of porcelain which fabricated by the conventional build-up method. RESULTS: There was no significant difference in physical properties and color stability between two fabrication methods after various testing methods. Conclusion: This new build-up method can be applied to fabricate the PFM crown and bridge without any loss of strength and optical properties.