• Title/Summary/Keyword: Dental instruments

Search Result 208, Processing Time 0.026 seconds

A Study on the Consciousness of Dental Technicians about the Courses of Dental Technology Dept., Junior College, Korea (한국(韓國) 치과기공사(齒科技工士)들의 전문대학(專門大學) 치기공과(齒技工科) 교육(敎育)에 대한 의식구조(意識構造) 조사(調査) 연구(硏究))

  • Choi, Un-Jea
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.63-89
    • /
    • 1997
  • This survey aimed at the analysis of the consciousness of the dental technicians on the college education ; 205 dental technicians who graduated the relavant school answered. Following is the result of the analysis with its ststistcal number. 1. About the time when they chose their major, 84 people(41.1%) answered the prepartion period for the college. And, 74(36.1%) said that they applied on their own thought to their major. The reason why they chose it was first the prosperity expected in the near future, 93(45.4%) replied. 2. 161(78.5%) were satisfied with their college days. On the other hand, the most regretful one those days, 69(33.7%) answered, was the scarcity of the study seminar. 3. About the exercise courses, 120(58.6%) showed dissatisfaction, and 66(32.3%) people of the dissatisfied pointed out the lack of the instruments. 4. The suitable number in a class, 124(60.5%) supported, is 20 heads. The appropriate period of education was said three years by 71(34.6%), four years 53(25.9%) and the extension to the graduate school by 41(20.0%) 5. About the tips for the professors, 147(71.7%) proposed they would research and lecture further more. To the college administration, 116(56.5%) suggested it should accomo-data enough instruments for practicing.

  • PDF

Qualitative evaluation of dental hygiene students following the application of the Capstone Design in dental hygiene theory and practice (일부 치위생학과 캡스톤 디자인 기반의 임상치위생학 수업 경험에 관한 질적 연구: 성찰일지 분석을 중심으로)

  • Choi, Yong-Keum;Jeon, Hyun-Sun;Park, Hyang-Ah
    • Journal of Korean Dental Hygiene Science
    • /
    • v.4 no.2
    • /
    • pp.77-88
    • /
    • 2021
  • Background: In this study, the Capstone Design was applied to the clinical dental hygiene course of the Department of Dental Hygiene, and its effect was confirmed by qualitatively evaluating the students' reflection on the capstone design class experience. Methods: This study was conducted for the "Clinical Dental Hygiene and Practice III" course, in which third year students develop the ability to judge and plan dental hygiene based on problem-solving ability and critical thinking. By applying the Capstone Design within the core curriculum of the class, the students analyzed problems based on their major knowledge of dental hygiene in order to improve their ability to manipulate periodontal instruments, and focusedon the process of developing the contents of periodontal instruments by using them. Results: The application of Capstone Design on clinical dental hygiene and practice III classes increased students' active class participation, and through the problem-solving process, students' learning and confidence improved. Conclusion: The Capstone Design can be viewed as a teaching method that promotes the participation of students in the dental hygiene department and can effectively help their learning and confidence through a problem-solving process.

A Study on the Change of Clinical Self-Confidence according to the Number of Clinical Dental Hygiene Practices of Students in the Department of Dental Hygiene - Focusing on scaling practices -

  • Choi, Yong-Keum;Kim, Mi-Sun;Jeong, Su-Ra;Kim, Eun-Jeong
    • Journal of Korean Dental Hygiene Science
    • /
    • v.3 no.2
    • /
    • pp.39-49
    • /
    • 2020
  • The purpose of this study was to provide the basic data needed to plan the effective teaching design of scaling education and to measure the changes in students' confidence in performing scaling according to the number of scaling practices. Scaling education is presented as a core basic hygiene competency of dental hygienists and evaluated as the practical competency of dental hygienists. This study selected 48 third-year students from the department of dental hygiene at S University in Asan, and analyzed data from completed participant surveys. The degree of "confidence in facing the subject in clinical practice," "confidence in applying hand instrument to the subject," and "confidence in applying ultrasonic instruments to the subject" was assessed on a five-point Likert scale. The difference in confidence was analyzed during five practice sessions. Each response was compared using frequency analysis, chi-square test, and repeated measurement ANOVA. Students who complained of a lack of confidence in the 14.6%, 25.0%, and 12.5%, respectively, in face-to-face practice, hand instruments, and ultrasonic instrument application responses. The more the practice was repeated, the more confident students were in all three categories, and the more statistically significant (p<0.001). As the number of scaling practice sessions increased, students' confidence in performing scaling also improved. In particular, the level of self-confidence was higher after the third practice session when compared to the first session. Therefore, it is necessary to design effective courses for teaching scaling practices so that at least three repetitive practice periods can be provided in clinical dental hygiene practices.

Study on the Infection Control and Dental waste Disposal in Dental Clinic Located in Seoul City (서울시 치과의원의 진료실 감염관리 및 폐기물 처리 실태 조사연구)

  • Kang, Jae-Kyoung;Kim, Eun-Sook;Kim, Kyung-Mi
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.105-113
    • /
    • 2002
  • This study was aimed to investigate the practice on the infection control and dental waste disposal in dental clinic. The data used in this study had been collected in 100 dental clinics located in Seoul city from August to October, 2001. It was shown that examination instruments, oral surgery instruments, and periodontal instruments were almost sterilization in dental clinic. It was high in the recognition of individual protection but it was low in the degree of practice. Therefore, the practice in infection control is very important to dental team for safety of patients and operators.

  • PDF

The survey on the infection control of noncritical instruments used in dental treatment (치과 치료에 사용되는 비위험 기구의 감염 관리 실태 조사)

  • Kim, Jae Hyun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.27-36
    • /
    • 2019
  • Purpose: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. Materials and Methods: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. Results: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. Conclusion: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.

Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

  • Kwak, Sang-Won;Ha, Jung-Hong;Lee, WooCheol;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.270-275
    • /
    • 2014
  • Objectives: This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. Materials and Methods: The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3 mm from the tip and then bent $45^{\circ}$ with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3 mm, and clockwise rotations (2 rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. Results: The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). Conclusions: The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

The effects of physical decontamination methods on zirconia implant surfaces: a systematic review

  • Tan, Nathan Chiang Ping;Khan, Ahsen;Antunes, Elsa;Miller, Catherine M;Sharma, Dileep
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.5
    • /
    • pp.298-315
    • /
    • 2021
  • Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implantgrade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research-specifically, randomised controlled trials-would further confirm the effects of physical decontamination methods in a clinical setting.

Characteristics of the molar surface after removal of cervical enamel projections: comparison of three different rotating instruments

  • Ko, Min-Jeong;Cho, Chan-Myung;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate and compare tooth surface characteristics in extracted human molars after cervical enamel projections (CEPs) were removed with the use of three rotating instruments. Methods: We classified 60 extracted molars due to periodontal lesion with CEPs into grade I, II, or III, according to the Masters and Hoskins' criteria. Each group contained 20 specimens. Three rotating instruments were used to remove the CEPs: a piezoelectric ultrasonic scaler, a periodontal bur, and a diamond bur. Tooth surface characteristics before and after removal of the projections were then evaluated with scanning electron microscopy (SEM). We analyzed the characteristics of the tooth surfaces with respect to roughness and whether the enamel projections had been completely removed. Results: In SEM images, surfaces treated with the diamond bur were smoothest, but this instrument caused considerable harm to tooth structures near the CEPs. The piezoelectric ultrasonic scaler group produced the roughest surface but caused less harm to the tooth structure near the furcation. In general, the surfaces treated with the periodontal bur were smoother than those treated with the ultrasonic scaler, and the periodontal bur did not invade adjacent tooth structures. Conclusions: For removal of grade II CEPs, the most effective instrument was the diamond bur. However, in removing grade III projections, the diamond bur can destroy both adjacent tooth structures and the periodontal apparatus. In such cases, careful use of the periodontal bur may be an appropriate substitute.

Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study (Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구)

  • Kim, Hyeon-Cheol;Kwak, Sang Won;Ha, Jung-Hong
    • The Journal of the Korean dental association
    • /
    • v.55 no.10
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

The effects of depression and anxiety on pain in ultrasonic scaling treatment (초음파스케일링 시 환자의 우울, 불안이 통증에 미치는 영향)

  • Hwang, Mi;Kim, Sook-Hyang;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.3
    • /
    • pp.439-446
    • /
    • 2014
  • Objectives : The purpose of the study is to investigate the correlation between the pain, depression, dental anxiety in the patients visiting to dental clinic for the ultrasonic scaling treatment. Methods : The study is a cross-sectional correlation study. A self-reported questionnaire was filled out by 254 patients having no history of mental illness in Seoul and Gyeonggido from December 12 to 20, 2013. The study instruments included modified Beck's Depression Inventory (BDI), STAI items by Spilberger, Humphis' Modified Dental Anxiety Survey(MDAS), and Visual Analogue Scale. Results : There existed correlation between the ultrasonic scaling pain, depression, dental anxiety, trait anxiety, and state anxiety. Dental anxiety was the most influencing factors on the pain. Conclusions : It is very important to reduce the anxiety in the patients more actively.