• Title/Summary/Keyword: Dental impression

Search Result 348, Processing Time 0.024 seconds

A COMPARISON OF THE FORM OF THE FACE, THE DENTAL ARCH AND THE MAXILLARY CENTRAL INCISOR (안모, 치열궁 및 상악 중절치의 형태에 관한 상호 비교 연구)

  • Lee Bong-Ho;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.273-285
    • /
    • 1992
  • The purpose of this study was to evaluate facial form, arch form and tooth form in young adults to determine if a correlation exists. 115 subjects who had healthy natural maxillary incisors and good occlusion consisted of 71 males and 44 females ranging from 20-30 years of age. Facial photographs and, intraoral photographs of upper anterior teeth and dental casts of upper jaws were taken to demonstrate facial form, dental arch form and tooth form. Form analysis is determined by comparing the ratio of the widths of the faces, dental archs and the teeth. The Chi-square test of independence between facial form, arch form and tooth form, was executed and the significance level determined. The results were as follows : 1. The distribution of facial forms was 66.1% square-tapering, 27.0% square, 5.2% ovoid, 2% tapering-square. 2. The distribution of tooth forms was 65.2% ovoid, 20.0% square-tapering, 11.3 % tapering-square, 3.5 % square. 3. The distribution of arch forms was 50.4 % square-tapering, 48.7 % tapering, 0.9 % reverse tapering-square. 4. There was no large differences in the distribution of facial forms, dental arch forms and tooth-forms between male and female. 5. No relationship existed between the tooth form and the facial form. 6. No relationship existed between the facial form and the dental arch form. 7. No relationship existed between the tooth form and the dental arch form. 8. This gave the impression that dental arch form and facial form could not be used as a true index in tooth selection.

  • PDF

Accuracy Verification of 3D printing model by Using Domestic Oral Scanner(eZIS) (국내산 구강스캐너(eZIS)를 사용한 3D프린트 모형의 정확도 검증 실험)

  • Byun, Tae-hee;Nam, Min-kyung;Kim, Jung-ho;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.40 no.3
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The purpose of this study was establishing process of manufacturing dental prosthesis by using eZIS system(DDS Inc.,Korea). Methods: To evaluate accuracy verification, the test was practiced two ways. First, Comparison of 3D printing models and stone models was practiced by using 3D superimposing software. #36 prepared master model was scanned by eZIS system and three 'Veltz3D' 3D printing models and three 'Bio3D' 3D printing models were manufactured. three stone models were manufactured by conventional impression technique. Second, Fitness test was practiced. the 3D printing models and the stone models was compared by manufacturing same resin crown. #36 prepared master model was scanned 9 times and manufactured (milled) 9 resin crowns by eZIS system. These crowns were cemented three 'Veltz3D' 3D printing models, three 'Bio3D' 3D printing models and three stone models. These crowns were sliced mesiodistal axis and gaps were measured by digital microscope. Results: The average accuracy of Bio3D models were 65.75%. Veltz3D(Hebsiba) models were 60.11% Stone models were 41.00%. Conclusion : This study results showed 3D printing model is similar with stone model. So it was under clinical allow, didn't affect final dental prothesis. There were no significant differences in the appearance of the three types of milling crowns.

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

A Study on The Dental field of Present Health Insurance for custom-made Prosthetic implant by Dental technicians (건강보험 급여화 관련 치과임플란트보철물 제작실태 연구)

  • Lee, Heekyung;Cho, Mihyang
    • Journal of Technologic Dentistry
    • /
    • v.38 no.1
    • /
    • pp.9-22
    • /
    • 2016
  • Purpose: The Purpose of this study are to describe the Dental field of present health insurance for custom-made prosthetic implant by dental technicians' work. Results: A total of 300 dental technicians working at dental laboratories in Korea were randomly selected and surveyed, 206(68.7%) of them were used for the statistical analysis. Conclusion: Average daily working time was 10 hours 66%. The average cumulative credit of the clinic for dental prosthesis fabrication rates was Less than 10 million won(21.8%), 10~80 million won(11.7%), more than one hundred million won(1.5%). Remake dental prosthesis was one more than the monthly average of 98.5%. Causes of remake dental prosthesis was dentist impression 83% but did not pay 62.5%. Dental technicians Implant production period was 7 days(48.5%), 10 days(35%) was commissioned by dentists production time is 5 days(46.1%), 7 days(36.5%). President of dental laboratories 3.86 points and dental technicians 3.06 points knew differently about starting of implant health insurance coverage(p<.001). They alike were in favor of insurance coverage for the implant. Dental technicians were lower by 2.36 points for work do you know whether your health insurance application of dental prostheses. Dental technicians are 2.16 points on whether confidence in the pores payment of insurance coverage dental prosthesis, dental laboratory president was lower by 1.85 points. They are very low with 1.97 points on whether confidence in the rate payment of health insurance coverage dental prosthesis(p<.01). The implant prosthesis abutment selected, the abutments designed, design of the implant upper prosthetic, the upper prosthetic fitting dental technicians participate of dental laboratory president showed higher score (p <.05). Conclusion: Hours of dental technicians were making this short period of remake dental prosthesis-related dental prosthesis. Dental clinic and a detailed representation of the dental prosthodontic fabrication request is required for communication between the laboratory in order to reduce the remake of a dental prosthesis, dental insurance coverage written dental prosthodontic fabrication request should be legislated. Implant classification standard medical practice 1-3 Step conduct a thorough costing a total of no. 73 of the correct classification standard medical practice in addition to eight times defined by the act of dental technicians should be defined.

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

The relationship of maxillary canines to the facial anatomical landmarks in a group of Thai people

  • Sinavarat, Potchaman;Anunmana, Chuchai;Hossain, Sharafat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.369-373
    • /
    • 2013
  • PURPOSE. The objective was to evaluate canine positions, intercanine tip width (ICTW) and width of distal surface of canine (WDC), related to facial landmarks including interalar width (IAW), intercommissural width (ICoW), and distance between left and right projection lines drawn from inner canthus of eyes to alae of the nose (DPICa) in a group of Thai. MATERIALS AND METHODS. One hundred Thai subjects aged 18-35 years were selected. IAW and ICoW were measured on subject's face using digital vernier caliper. Irreversible hydrocolloid impression of the upper arch was taken, and a cast was poured with dental stone. Silicone impression material was used to take imprint of the incisal edge of upper six anterior teeth. DPICa was obtained from the subject's face using custom-made measuring equipment and marked on the silicone incisal imprint. The marks were then transferred from the imprint to the stone cast and measured with digital caliper. The ICTW and WDC were also measured on the stone cast. Pearson's correlation was used to determine the correlation. RESULTS. The results revealed that the correlation between ICTW-ICoW was 0.429 and ICTW-DPICa was 0.573. The correlation between WDC-ICoW was 0.426 and WDC-DPICa was 0.547. However, IAW did not show any correlation with ICTW or WDC (P>.05). CONCLUSION. The correlation between canine position and facial landmarks was found. ICTW and WDC had relationship with ICoW and DPICa. DPICa showed stronger correlation with the position of maxillary canine than that of ICoW.

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption using mandibular suction denture with closed mouth technique: a clinical report (치조골 흡수가 심한 완전 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Ko, Chang Woo;Min, Byungkwee;Yang, Hong-so;Lim, Hyun-Pil;Yun, Kwidug;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • When it comes to treat patient with loss of vestibule, conventional denture impression have limitation which can cause problems of excessive border extension. Suction denture with closed mouth technique which was introduced to solve this problem, forms negative pressure being sealed denture flanges by mobile mucosa when the patient swallows and chews. Also, it can decrease patient's visiting time by taking impression and gothic arch tracing at once. In this case, considering patient's chief complain which is a loose fit of present lower denture, suction dentures with closed mouth technique was planned.

Fabrication of immediate complete denture using Campagna tray technique (전악 발치 환자에서 캠퍼그나 트레이를 적용한 즉시의치 수복 증례)

  • Kim, Nam-Hoon;Kim, Jong-Eun;Oh, Kyung Chul;Chung, Moon-Kyu;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.331-335
    • /
    • 2017
  • An immediate complete denture is considered as restoration for lost natural teeth, which is fabricated following the extraction of the remaining teeth. Current esthetics and function can be retained by using immediate denture without edentulous period. However, the major disadvantages of immediate denture relate to the difficulties associated with taking accurate definitive impression and predicting the results of immediate denture. In this case report, the Campagna tray technique was used to take the final impression in a 49-year-old male patient presented with all remaining teeth diagnosed as hopeless teeth. Surgical templates were used for alveoloplasty after extraction. The immediate complete dentures were then delivered. The clinical assessments of immediate dentures showed good esthetic and functional outcomes. The patient showed high level of satisfaction.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE-ARCH IMPRESSIONS (전악인상채득시 인상용 트레이가 경석고 모형의 정확도에 미치는 영향)

  • Ryu Su-In;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of reproduction of stone casts made from complete-arch impressions using different trays. The trays used were : 1) nonperforated custom tray, 2) perforated custom tray, 3) nonperforated Rim-Lock tray, 4) perforated stock tray. Impressions were made from an dentulous acrylic resin model with metal inserts in first premolars and second molars. Transverse distance, sagittal distance and diagonal distance were measured using 4 landmarks. Measurements were made by using 3 dimensional measuring machine. The impression material used was an addition silicone. Impressions were poured at once with a Type IV dental stone. Data were analyzed using ANOVA and student t-test with a sample size of five. The results were as follows : 1. There were statistical differences in amount of dimensional change in according to the tray types. In amount of mean dimensional change, perforated custom tray was the first smallest, nonperforated custom tray was the second, nonperforated Rim-Lock tray and perforated stock tray were the largest. 2. There were statistical differences in amount of dimensional change between nonperforated custom tray and nonperforated Rim-Lock tray, and between perforated custom tray perforated stock tray. 3. There were satistical differences in amount of dimensional change between nonperforated custom tray and perforated custom tray, but there was not a statistical difference between nonperforated Rim-Lock tray and perforated stock tray. 4. There was not a statistical difference in amount of dimensional change between upper and lower arch in all tray types.

  • PDF