• Title/Summary/Keyword: Dental implants

Search Result 1,452, Processing Time 0.028 seconds

Short dental implants in the posterior maxilla: a review of the literature

  • Esfahrood, Zeinab Rezaei;Ahmadi, Loghman;Karami, Elahe;Asghari, Shima
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.70-76
    • /
    • 2017
  • The purpose of this study was to perform a literature review of short implants in the posterior maxilla and to assess the influence of different factors on implant success rate. A comprehensive search was conducted to retrieve articles published from 2004 to 2015 using short dental implants with lengths less than 10 mm in the posterior maxilla with at least one year of follow-up. Twenty-four of 253 papers were selected, reviewed, and produced the following results. (1) The initial survival rate of short implants in the posterior maxilla was not related to implant width, surface, or design; however, the cumulative success rate of rough-surface short implants was higher than that of machined-surface implants especially in performance of edentulous dental implants of length <7 mm. (2) While bone augmentation can be used for rehabilitation of the atrophic posterior maxilla, short dental implants may be an alternative approach with fewer biological complications. (3) The increased crown-to-implant (C/I) ratio and occlusal table (OT) values in short dental implants with favorable occlusal loading do not seem to cause peri-implant bone loss. Higher C/I ratio does not produce any negative influence on implant success. (4) Some approaches that decrease the stress in posterior short implants use an implant designed to increase bone-implant contact surface area, providing the patient with a mutually protected or canine guidance occlusion and splinting implants together with no cantilever load. The survival rate of short implants in the posterior edentulous maxilla is high, and applying short implants under strict clinical protocols seems to be a safe and predictable technique.

Patients' knowledge and awareness of dental implants in a Turkish subpopulation

  • Tomruk, Ceyda Ozcakir;Ozkurt-Kayahan, Zeynep;Sencift, Kemal
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.133-137
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate the patients' knowledge on dental implants in a Turkish subpopulation. MATERIALS AND METHODS. Five hundred twenty seven Turkish adults referred to Yeditepe University Faculty of Dentistry, Istanbul, Turkey, were presented with a questionnaire including 20 questions regarding the level of information and awareness about the dental implants. The data were collected and statistical analyses were performed with Chi square test to compare the descriptive data. RESULTS. Among 527 subjects, 54% were female and 46% were male with a mean age of 42.2 years. The rate of patients' implant awareness was 27.7%. When the patients were questioned about the treatment options for rehabilitation of tooth missing, 60.9% of patients were informed about fixed partial denture, followed by conventional complete denture (32.5%) and removable partial denture (24.9%). Six percent reported that they were very well informed about the dental implants whereas 48.2% were poorly informed. The information sources of the implants were from the dentist (44.5%), printed media (31.6%) and friends and acquaintances (17.3%), respectively. Sixteen percent of the population believed that their implants would last forever. CONCLUSION. The dentists should give more detailed information to the patients about dental implants and tooth-supported fixed partial dentures in the future.

Comparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants

  • Choi, Hae Won;Park, Young Seok;Chung, Shin Hye;Jung, Min Ho;Moon, Won;Rhee, Sang Hoon
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.229-237
    • /
    • 2017
  • Objective: The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. Methods: Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8.0 mm) were inserted perpendicularly in solid polyurethane foam with varying densities of 20 pounds per cubic foot (pcf), 30 pcf, and 40 pcf. Primary stability was measured as maximum insertion torque (MIT) and maximum removal torque (MRT). To investigate clinical applicability, compressive and tensile forces were recorded at 0.01, 0.02, and 0.03 mm displacement of the implants at angles of $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$, and $40^{\circ}$. The biocompatibility of zirconia micro-implants was assessed via an experimental animal study. Results: There were no statistically significant differences between zirconia micro-implants and titanium alloy implants with regard to MIT, MRT, or the amount of movement in the angulated lateral displacement test. As angulation increased, the mean compressive and tensile forces required to displace both types of micro-implants increased substantially at all distances. The average bone-to-implant contact ratio of prototype zirconia micro-implants was $56.88{\pm}6.72%$. Conclusions: Zirconia micro-implants showed initial stability and clinical applicability for diverse orthodontic treatments comparable to that of titanium micro-implants under compressive and tensile forces.

Prognosis after treatment with multiple dental implants under general anesthesia and sedation in a cerebral palsy patient with mental retardation: A case report

  • Hong, Young-Joon;Dan, Jung-Bae;Kim, Myung-Jin;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • Cerebral palsy is a non-progressive disorder resulting from central nervous system damage caused by multiple factors. Almost all cerebral palsy patients have a movement disorder that makes dental treatment difficult. Oral hygiene management is difficult and the risks for periodontitis, dental caries and loss of multiple teeth are high. Placement of dental implants for multiple missing teeth in cerebral palsy patients needs multiple rounds of general anesthesia, and the prognosis is poor despite the expense. Therefore, making the decision to perform multiple dental implant treatments on cerebral palsy patients is difficult. A 33-year-old female patient with cerebral palsy and mental retardation was scheduled for multiple implant treatments. She underwent computed tomography (CT) under sedation and the operation of nine dental implants under general anesthesia. Implant-supported fixed prosthesis treatment was completed. During follow-up, she had the anterior incisors extracted and underwent the surgery of 3 additional dental implants, completing the prosthetic treatment. Although oral parafunctions existed due to cerebral palsy, no implant failure was observed 9 years after the first implant surgery.

Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.351-360
    • /
    • 2020
  • PURPOSE. The aim of the present study was to compare the stress distributions on the dental implants, abutments, and bone caused by different overdenture attachment types under functional chewing forces. MATERIALS AND METHODS. The 3D finite element models of the mandible, dental implants, attachment types, and prostheses were prepared. In accordance with a conventional dental implant supported overdenture design, the dental implants were positioned at the bone level in the canine teeth region bilaterally. A total of eight models using eight different attachment systems were used in this study. All the models were loaded to simulate chewing forces generated during the centric relationship (450 N), lateral movement (400 N), protrusive movement (400 N), and also in the presence of a food mass unilaterally (200 N). Stress outputs were obtained as the maximum principal stress and the equivalent von-Mises stress. RESULTS. In all attachment types, higher stress values were observed in the abutments, dental implants, and bone in the magnet attachments in different loading conditions. The highest stress values were observed among the magnet systems in the components of the Titanmagnetics model in all loading conditions (stresses were 15.4, 17.7, and 33.1 MPa on abutment, dental implant, and bone, respectively). The lowest stress value was observed in the models of Zest and O-Ring attachments. CONCLUSION. The results of the present study implied that attachment types permitting rotation and tolerating various angles created lower stresses on the bone, dental implants, and abutments.

Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits

  • Koh, Jung-Woo;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2009
  • STATEMENT OF PROBLEM. Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant. PURPOSE. The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model. MATERIAL AND METHODS. Three test groups were prepared: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion. RESULTS. The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P <. 05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P >. 05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P >. 05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups. CONCLUSION. The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.

A retrospective study on related factors affecting the survival rate of dental implants

  • Jang, Hee-Won;Kang, Jeong-Kyung;Lee, Ki;Lee, Yong-Sang;Park, Pil-Kyoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.204-215
    • /
    • 2011
  • PURPOSE. The aim of this retrospective study is to analyze the relationship between local factors and survival rate of dental implant which had been installed and restored in Seoul Veterans Hospital dental center for past 10 years. And when the relationship is found out, it could be helpful to predict the prognosis of dental implants. MATERIALS AND METHODS. A retrospective study of patients receiving root-shaped screw-type dental implants placed from January 2000 to December 2009 was conducted. 6385 implants were placed in 3755 patients. The following data were collected from the dental records and radiographs: patient's age, gender, implant type and surface, length, diameter, location of implant placement, bone quality, prosthesis type. The correlations between these data and survival rate were analyzed. Statistical analysis was performed with the use of Kaplan-Meier analysis, Chi-square test and odds ratio. RESULTS. In all, 6385 implants were placed in 3755 patients (3120 male, 635 female; mean age $65{\pm}10.58$ years). 108 implants failed and the cumulative survival rate was 96.33%. There were significant differences in age, implant type and surface, length, location and prosthesis type (P<.05). No significant differences were found in relation to the following factors: gender, diameter and bone quality (P>.05). CONCLUSION. Related factors such as age, implant type, length, location and prosthesis type had a significant effect on the implant survival.

The feasibility of immediately loading dental implants in edentulous jaws

  • Henningsen, Anders;Smeets, Ralf;Wahidi, Aria;Kluwe, Lan;Kornmann, Frank;Heiland, Max;Gerlach, Till
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.234-243
    • /
    • 2016
  • Purpose: Immediate loading of dental implants has been proved to be feasible in partially edentulous jaws. The purpose of this retrospective investigation was to assess the feasibility of immediately loading dental implants in fully edentulous jaws. Methods: A total of 24 patients aged between 53 and 89 years received a total of 154 implants in their edentulous maxillae or mandibles. Among the implants, 45 were set in fresh extracted sockets and 109 in consolidated alveolar bones. The implants were provisionally managed with chair-side made provisional resin bridges and exposed to immediate loading. Implants were followed up for 1-8 years, including radiographic imaging. Marginal bone levels were evaluated based on radiographic imaging. Results: A total of 148 out of the 154 implants survived over the follow-up period of 1 to 8 years, giving a survival rate of 96%. The time or region of the implantation, the pre-implant augmentation, and the length and diameter of the implants had no statistically significant influence on the survival or the success rate. The marginal bone level remained stable with only minimal loss of 0.3 mm after 60 months of loading. Conclusions: Within the limitations of this study, immediate loading is feasible for dental implants in edentulous jaws.

Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up

  • Francetti, Luca;Rodolfi, Andrea;Barbaro, Bruno;Taschieri, Silvio;Cavalli, Nicolo;Corbella, Stefano
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.210-215
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the cumulative success rate, the implant survival rate, and the occurrence of biological complications in implants supporting full-arch immediately loaded rehabilitations supported by upright and tilted implants. Methods: The clinical records and periapical radiographs of patients who attended follow-up visits were collected, and information was recorded regarding marginal bone loss resorption, the occurrence of peri-implant infectious diseases, and the implant survival rate. Implants were classified as successful or not successful according to two distinct classifications for implant success. Results: A total of 53 maxillary and mandibular restorations including 212 implants were analysed, of which 56 implants were studied over the full five-year follow-up period. After five years, the cumulative success rate was 76.04% according to the Misch classification and 56.34% according to the Albrektsson classification. The cumulative implant survival rate was 100%, although one implant was found to be affected by peri-implantitis at the second follow-up visit. Conclusions: The cumulative success rate of the implants dropped over time, corresponding to the progression of marginal bone resorption. The prevalence of peri-implantitis was very low, and the implant survival rate was not found to be related to the cumulative success rate.

7-mm-long dental implants: retrospective clinical outcomes in medically compromised patients

  • Nguyen, Truc Thi Hoang;Eo, Mi Young;Cho, Yun Ju;Myoung, Hoon;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.260-266
    • /
    • 2019
  • Objectives: Dental implants shorter than 8 mm, called short dental implants (SDIs), have been considered to have a lower success rate than standard length implants. But recent studies have shown that SDIs have a comparable success rate, and implant diameter was more important for implant survival than implant length. Also, SDIs have many advantages, such as no need for sinus lifting or vertical bone grafting, which may limit use in medically compromised patients. Materials and Methods: In this study, 33 patients with 47 implants 7-mm long were examined over the last four years. All patients had special medical history and were categorized into 3 groups: systemic disorders, such as diabetes mellitus (controlled or uncontrolled), mental disability, and uncontrolled hypertension; oral cancer ablation with reconstruction, with or without radiotherapy; diverse osteomyelitis, such as osteoradionecrosis and bisphosphonate-related osteonecrosis of the jaw. Most of these patients have insufficient residual bone quality due to mandible atrophy or sinus pneumatization. Results: The implant diameters were 4.0 (n=38), 4.5 (n=8), and 5.0 mm (n=1). Among the 47 implants placed, 2 implants failed before the last followup. The survival rate of 7-mm SDIs was 95.74% from stage I surgery to the last follow-up. Survival rates did not differ according to implant diameter. The mean marginal bone loss (MBL) at 3 months, 1 and 2 years was significantly higher than at implant installation, and the MBL at 1 year was also significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly. Conclusion: Within the limitations of the present study, the results indicate that SDIs provide a reliable treatment, especially for medically compromised patients, to avoid sinus lifting or vertical bone grafting. Further, long-term follow-up is needed.