• 제목/요약/키워드: Dental implants

검색결과 1,465건 처리시간 0.03초

Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials

  • Mortazavi, Hamed;Khodadoustan, Amin;Kheiri, Aida;Kheiri, Lida
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.153-174
    • /
    • 2021
  • Dental implants are popular for dental rehabilitation after tooth loss. The goal of this systematic review was to assess bone changes around bone-level and tissue-level implants and the possible causes. Electronic searches of PubMed, Google Scholar, Scopus, and Web of Science, and a hand search limited to English language clinical trials were performed according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines up to September 2020. Studies that stated the type of implants used, and that reported bone-level changes after insertion met the inclusion criteria. The risk of bias was also evaluated. A total of 38 studies were included. Eighteen studies only used bone-level implants, 10 utilized tissue-level designs and 10 observed bone-level changes in both types of implants. Based on bias assessments, evaluating the risk of bias was not applicable in most studies. There are vast differences in methodologies, follow-ups, and multifactorial characteristics of bone loss around implants, which makes direct comparison impossible. Therefore, further well-structured studies are needed.

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.

의료기기에 대한 임상모니터링 기반의 지속적 품질개선: 치과용 임플란트의 사례 (Continuous Quality Improvement of Medical Equipments Based on Clinical Monitoring: A Case Study of Dental Implants)

  • 김명덕;엄태관;김영진
    • 품질경영학회지
    • /
    • 제36권2호
    • /
    • pp.59-66
    • /
    • 2008
  • Dental implant has recently become one of the most viable treatment options for regaining the oral function and dental aesthetics compared with conventional fixed or removable dentures. Dental implants vary in material, dimensions, geometries, surface properties, and interface geometries. It has been reported that there has been a proliferation of manufacturers who produce implants using various materials and surface treatments, and the dentist needs to select from over 2,000 different dental implants and abutments in a specific treatment situation. Unfortunately, however, no metrics have been specifically identified for the purpose of quality assessment and selection of an appropriate dental implant. This study aims to provide practical guidelines for quality assessment of dental implant based on clinical data. Like other medical devices and materials, the superiority related to specific characteristics of the dental implant needs to be verified through extensive clinical studies. The procedures of clinical monitoring for dental implants have been proposed along with a case study to exemplify the usefulness of clinical monitoring for the purpose of continuous quality improvement in medical industry.

Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results

  • Park, Han;Moon, Ik-Sang;Chung, Chooryung;Shin, Su-Jung;Huh, Jong-Ki;Yun, Jeong-Ho;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제51권6호
    • /
    • pp.422-432
    • /
    • 2021
  • Purpose: The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading. Methods: Twelve patients were recruited. Two types of implants were placed adjacent to each other: 1 straight implant and 1 tapered implant. Marginal bone loss, mPI, and mBI were measured every year for 5 years after loading. Results: The straight implants showed 0.2±0.4 mm of marginal bone loss at 5 years after loading, while the tapered implants showed 0.2±0.3 mm of marginal bone loss; this difference was not statistically significant (P=0.833). Our analysis also showed no statistically significant differences in mPI (straight implants: 0.3±0.3 vs. tapered implants: 0.2±0.3; P=0.414) or in mBI (straight implants: 0.3±0.4 vs. tapered implants: 0.2±0.3; P=0.317) at 5 years after prosthesis delivery. Conclusions: Straight and tapered implants showed no significant differences with respect to marginal bone loss, mPI, and mBI for 5 years after loading.

임상가를 위한 특집 2 - 임플란트시술을 위한 CBCT의 활용 (CBCT Imaging for Dental Implants)

  • 안서영
    • 대한치과의사협회지
    • /
    • 제50권4호
    • /
    • pp.189-195
    • /
    • 2012
  • Various imaging modalities have been used for dental implant assessment in the different stages of implant treatment. Basic imaging, such as panoramic and periapical radiographs, are generally useful and cost-effective but do not provide the cross-sectional visualization or interactive image analysis that can be obtained with more sophisticated imaging techniques, such as Cone-Beam Computed Tomography(CBCT) imaging. This article includes the applications of CBCT imaging and their diagnostic contribution to presurgical evaluation, treatment planning, and postoperative assessment of dental implants.

악안면 외상 후 식립된 임플란트의 예후에 관한 연구 (THE STUDY ON THE PROGNOSIS OF DENTAL IMPLANTS WHICH HAS BEEN INSTALLED AFTER MAXILLOFACIAL TRAUMA)

  • 전하룡;김종원;홍종락;김창수
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권4호
    • /
    • pp.348-351
    • /
    • 2006
  • Purpose The purpose of this study was to evaluate the success rate of dental implant on post-traumatic region to rehabilitate missing teeth. Patients and Methods 5 patients who had been treated due to maxillofacial trauma during 2000 to 2004 at samsung medical center were selected for this study. 22 dental implants were installed to them for restoring missing teeth. The success rate of these dental implants was evaluated with criteria by T. Albrektsson. We divided installed 22 implants into 2 categories. One category consisted rough surface implants group and smooth surface implants group. And the other category consisted more healing group and less healing group. The healing time was calculated from point of trauma. Results The success rate of dental implants is 68.2% that is lower than other studies because of poor vascularity of bone bed and mechanical stress according to trauma. Rough surface implants group and More healing group showed superior success rate to others. (P < 0.05). Conclusion We found that to increase success rate, it may need rough surface implants and longer healing period.

Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading

  • Alan, Raif;Marakoglu, Ismail;Haliloglu, Seyfullah
    • Journal of Periodontal and Implant Science
    • /
    • 제45권5호
    • /
    • pp.169-177
    • /
    • 2015
  • Purpose: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin-K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. Methods: A total of 78 non-submerged implants (Euroteknika, $Aesthetica^{+2}$, Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. Results: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG:sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. Conclusions: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.

Association Between Dental Implants and Cognitive Function in Community-dwelling Older Adults in Korea

  • Ki, Seungkook;Yun, Jihye;Kim, Jinhee;Lee, Yunhwan
    • Journal of Preventive Medicine and Public Health
    • /
    • 제52권5호
    • /
    • pp.333-343
    • /
    • 2019
  • Objectives: This study aimed to evaluate the association between dental implants and cognitive function in community-dwelling older adults. Methods: Data were collected from the baseline survey (2016-2017) of the Korean Frailty and Aging Cohort Study. The study sample comprised 1115 community-dwelling people aged 70 years to 84 years who had 0-19 natural teeth. Dental implants and natural teeth were identified by panoramic radiography, while the cognitive function was assessed by the Korean version of the Mini-Mental State Examination (MMSE-KC). The association between dental implants and cognitive function was analyzed by multiple linear regression. Sensitivity analysis was performed to test for potential bias. Results: The mean number of natural teeth in the study population was 9.50 (standard deviation [SD], 6.42), and the mean MMSE-KC score was 24.93 (SD, 3.55). In the simple univariate analysis, tooth replacement, age, sex, smoking status, alcohol consumption, body mass index, osteoporosis, number of natural teeth, periodontitis, chewing discomfort, tooth-brushing frequency, education level, monthly household income, participation in economic activity, living alone, and marital status had a significant impact on the association. After adjusting for confounders, the association between dental implants and cognitive function remained significant (B, 0.85; standard error, 0.40; p<0.05). Age, body mass index, periodontitis, tooth-brushing frequency, and education level were also significantly associated with cognitive function. The results of the sensitivity analyses were consistent with those of the primary analysis. Conclusions: Dental implants were associated with cognitive function in older adults living in the community. Dental implants as tooth replacements may play a role in preserving cognitive function.

Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits

  • Park, Eun Young;Sohn, Hae Ok;Kim, Eun-Kyong
    • Journal of Yeungnam Medical Science
    • /
    • 제36권1호
    • /
    • pp.43-49
    • /
    • 2019
  • Background: In the osseointegration of dental implants, the implant surface properties have been reported to be some of the most important critical factors. The effect of implant's surfaces created by resorbable blast media (RBM) followed by laser ablation on bone tissue reactions was examined using the removal torque test and histomorphometric analysis. Methods: Two types of dental implants, RBM-laser implants (experimental group) and RBM implants (control group) (CSM implant system, Daegu, Korea; L=6 mm, diameter=3.75 mm) were placed into the right and left distal femoral metaphysis of 17 adult rabbits. Six weeks after placement, removal torque was measured and histomorphometric analysis was performed. Results: The mean removal torque was $24.0{\pm}10.2Ncm$ and $46.6{\pm}16.4Ncm$ for the control and test specimens, respectively. The experimental RBM-laser implants had significantly higher removal torque values than the control RBM implants (p=0.013). The mean values of total and cortical bone to implant contact (BIC) were respectively $46.3{\pm}10.8%$ and $65.3{\pm}12.5%$ for the experimental group, and $41.9{\pm}18.5%$ and $57.6{\pm}10.6%$ for the control group. The experimental RBM-laser implants showed a higher degree of total and cortical BIC compared with RBM implants, but there was no statistical significance (p=0.482, 0.225). Conclusion: The removal torque and BIC of the test group were higher than those of the control group. In this study, the surface treatment created by RBM treatment followed by laser ablation appears to have a potential in improving bone tissue reactions of dental implants.

Photobiomodulation and implants: implications for dentistry

  • Tang, Elieza;Arany, Praveen
    • Journal of Periodontal and Implant Science
    • /
    • 제43권6호
    • /
    • pp.262-268
    • /
    • 2013
  • The use of dental implants has become a mainstay of rehabilitative and restorative dentistry. With an impressive clinical success rate, there remain a few minor clinical issues with the use of implants such as peri-implant mucositis and peri-implantitis. The use of laser technology with implants has a fascinating breadth of applications, beginning from their precision manufacturing to clinical uses for surgical site preparation, reducing pain and inflammation, and promoting osseointegration and tissue regeneration. This latter aspect is the focus of this review, which outlines various studies of implants and laser therapy in animal models. The use of low level light therapy or photobiomodulation has demonstrated its efficacy in these studies. Besides more research studies to understand its molecular mechanisms, significant efforts are needed to standardize the clinical dosing and delivery protocols for laser therapy to ensure the maximal efficacy and safety of this potent clinical tool for photobiomodulation.