• Title/Summary/Keyword: Dental implant prostheses

Search Result 215, Processing Time 0.024 seconds

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

Esthetic considerations for anterior implant-supported prostheses: focus on surgical and prosthetic treatment (전치부 임플란트의 연조직 심미성을 달성하기 위한 외과적, 보철적 고려사항)

  • Park, Yeon-Hee;Ahn, Seung-Geun;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.186-198
    • /
    • 2021
  • As the increased certainty of osseointegration, new parameters are now being used to assess implant success. Accordingly, patients' and clinicians' high demands and expectation for esthetics have expanded and implant-supported restorations show better esthetic outcomes. The pre-implant treatment planning process, the implant surgical steps and the post-surgery prosthetic process can affect all esthetic outcomes. Prevention of esthetic implant failures can be achieved by appropriate treatment at each stage, considering the 3 factors of alveolar bone, soft tissue, and implants. It is necessary to achieve the esthetic implant prostheses followings: minimal invasive surgery, bone augmentation, ideal 3-dimensional implant position, peri-implant soft tissue management, and provisional restorations to optimize peri-implant soft tissue architecture.

Angled implant brush for hygienic maintenance of full-arch fixed-implant rehabilitations: a pilot study

  • Setti, Paolo;Pesce, Paolo;Dellepiane, Elena;Bagnasco, Francesco;Zunino, Paola;Menini, Maria
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.5
    • /
    • pp.340-354
    • /
    • 2020
  • Purpose: This pilot study was conducted to evaluate the cleaning efficacy of an angled implant brush for home oral hygiene of full-arch fixed-implant prostheses. Methods: Forty-one patients treated with a full-arch implant rehabilitation in the maxilla or mandible (164 implants) for at least 4 months were enrolled. The screw-retained fixed prostheses were removed and baseline (T0) parameters were recorded, including plaque index (PI), probing depth (PD), and bleeding on probing (BOP). All patients completed a 5-item questionnaire on hygiene maintenance and received an implant brush for home hygiene. After 1 month (T1) PI, PD, and BOP were recorded again and patients completed a 7-item questionnaire to evaluate their satisfaction with the implant brush. One-way repeated-measures analysis of variance was conducted to evaluate the significance of changes in PI, PD, and BOP. A P value <0.05 was considered to indicate statistical significance. Results: A statistically significant reduction of BOP (0.62±0.6 at T0 vs. 0.5±0.5 at T1; P=0.032) was found, while no statistically significant changes in PD (1.74±0.5 mm at T0 vs. 1.77±0.5 mm at T1; P=0.050) or PI (1.9±0.7 at T0 vs. 1.7±0.7 at T1; P=0.280) occurred. According to the 7-item questionnaire, patients reported no difficulty in using the angled brush (63.4%) and deemed it highly (46.3%) or very highly (4.8%) effective in improving their home oral hygiene. Conclusions: Within the limits of the present pilot study, the patients experienced a reduction of BOP 1 month after being instructed to use the angled implant brush. The angled implant brush appeared to be a well-accepted device for home-care hygiene of full-arch fixed-implant rehabilitations.

The Application of CAD/CAM in Dentistry (임상가를 위한 특집 1 - CAD/CAM 치과적 응용)

  • Choi, Ho-Sik;Moon, Ji-Eun;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.110-117
    • /
    • 2012
  • Dental computer-aided design (CAD) and computer-aided manufacturing (CAM) technology have rapidly progressed over the past 30 years. The technology, which can be used in the dental laboratory, the dental office and the form of production centers, has become more common in recent years. This technology is now applied to inlays, onlays, crowns, fixed partial dentures, removable partial denture frameworks, complete dentures, templates for implant installation, implant abutments, and even maxillofacial prostheses. Dentists and dental technicians, who want to use these techniques, should have certain basic knowledge about that. This article gives an overview of CAD/CAM technologies, histories and how it applies in prosthetic dentistry.

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

CLINICAL STUDY OF MAXILLOFACIAL PROSTHESES;OSSEOINTEGRATED IMPLANTS FOR MAXILLOFACIAL PROSTHESES (악안면 보철의 임상적 고찰;골내 매식술을 통한 보철적 회복에 관하여)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.406-414
    • /
    • 2001
  • In recent decade, there has been a very rapid development in technical possibilities to provide patients with maxillofacial prostheses. Dr. Brenemark first introduced possibility of use of maxillofacial interosseous implant in patients with ablative tumor surgery in 1979. He did introduce the new type of maxillofacial implants system which widen the fixture flange on top of the bone. The advantages of fixed prostheses with implants were well known to various ways, easy to attach, keep clean prostheses, and not to disturb recipient bed. But there are some problems to install implants on maxillofacial regions, because mostly facial bone has very thin cortical bone and poor bone quality. It needs more retention between implant and bone which overcome that fault with fixture flange. To make maxillofacial prostheses, it should be understood general procedure of maxillofacial laboratory work. Ear and midface maxillofacial fabrication which include nose and eye defects will be described step by step.

  • PDF

Clinical considerations for appropriate occlusion of implant restorations (임플란트 보철 교합의 임상적 고려 사항)

  • Park, Young-Bum
    • The Journal of the Korean dental association
    • /
    • v.53 no.6
    • /
    • pp.418-426
    • /
    • 2015
  • The appropriate occlusion is one of the most important factors for the long-term success of implant and its restorations. The purpose of this review is to investigate and define occlusal considerations to reduce failure of implant prostheses. The physiological movement of implants is markedly lower than that of natural teeth and they also lack in occlusal sensitivity. Proper occlusal pattern may be assigned to compensate for the biological disadvantages and occlusal contacts must be formed where the cantilever effect is minimized. Moreover, the long-term success of implants after osseointegration can be assured by reducing early occlusal loading to avoid implant overloading and selecting appropriate occlusion material. Occlusal overload was brought by the number and location of occlusal contacts, which are under the clinician's control. The concept of implant occlusion is based on the concepts derived from traditional prosthetics. Moreover, there are few evidence on the concept or design of implant occlusion. Several occlusal design was recommended for implant prosthesis. Mutually protected occlusion, group function occlusion and bilateral balance occlusion was recommended for the specific types of implant restorations. This article reviews proper design of occlusion for implant restoration and offers occlusion strategy clinically.

Accuracy of several implant bite registration techniques: an in-vitro pilot study

  • Park, Do-Hyun;Park, Ji-Man;Choi, Jae-Won;Kang, Eun-Sook;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.341-349
    • /
    • 2017
  • PURPOSE. This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS. Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS. The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION. Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.

Implant-assisted removable partial denture using digital guide surgery in partially edentulous mandible: A case report (하악 부분 무치악 환자에서 디지털 가이드 수술을 이용한 임플란트 융합 가철성 국소의치 수복 증례)

  • Kim, Taehoon;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.88-96
    • /
    • 2021
  • Fixed implant prostheses or removable partial dentures are common treatment for partially dentulous patients. Recently, an implant-assisted removable partial denture (IARPD) has been introduced and is widely used. In the case of removable partial dentures using implant attachment and surveyed fixed prostheses, the consideration about parallelism of insertion path between implants and surveyed fixed prostheses is an important factor for success of IARPDs. In this case, she complained of discomfort while using the mandibular removable partial denture. Thus, an IARPD using implant surveyed fixed prostheses was fabricated. Thereafter, more implants were placed by a digital guide surgery to have the same insertion path as the existing surveyed fixed prostheses. Locator attachments were installed to the left and right premolar implants, and the left molar was able to obtain support of the removable partial denture with healing abutment. The clinical results were satisfactory on the aspect of aesthetic and masticatory function.