• Title/Summary/Keyword: Dental images

Search Result 816, Processing Time 0.021 seconds

Inter-observer reliability in cone-beam computed tomography assessment of the retromolar canal: A practical plan to improve diagnostic imaging

  • Igarashi, Chinami;Theramballi, Yeshoda Ganesh;Kobayashi, Kaoru
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Purpose: This study aimed to investigate inter-observer reliability among observers with different levels of proficiency and the diagnostic imaging reliability of cone-beam computed tomography (CBCT) images of the retromolar canal. Materials and Methods: CBCT images of 307 patients were assessed for the presence of retromolar canals(RMCs) by 3 observers independently. Diagnoses were made twice by each observer at intervals of more than 3 weeks. Interobserver reliability was assessed using the kappa coefficient. One observer had no experience in diagnosis using CBCT images. Therefore, a specialist in diagnostic imaging explained the CBCT images for interpretation and practiced diagnostic imaging together with this observer, while the other observer interpreted the images independently. Thereafter, the observers re-evaluated the images. Results: The interobserver kappa coefficients (including bilateral RMCs) calculated at the first reading were low, ranging from 0.21 to 0.61. Their values ranged from 0.95 (right side) to 1.00 (left side) after one-on-one practice with a diagnostic imaging specialist, while the values ranged from 0.65 (right side) to 0.66 (left side) without one-on-one practice. Conclusion: Diagnostic accuracy was improved through diagnostic imaging practice. To improve the anatomical interpretation of images, it is important to practice diagnostic imaging with a specialist in diagnostic imaging. One-on-one instruction about diagnostic imaging was an effective method of training.

Risk factors for external root resorption of maxillary second molars associated with third molars

  • Choi, Jinwoo
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • Purpose: This study aimed to evaluate the diagnostic performance of panoramic images compared to cone-beam computed tomography (CBCT) imaging for maxillary third molar (M3)-associated external root resorption (ERR), and to identify the risk factors of ERR on panoramic images. Materials and Methods: The study population was composed of all patients who underwent panoramic imaging at Dankook University Dental Hospital from May to October 2019. In total, 397 cases of maxillary M3s in 247 patients(147 men and 100 women) were included. The diagnostic accuracy of ERR in panoramic images compared to CBCT images was evaluated using the chi-square test. To identify risk factors for ERR, dental records and panoramic findings were evaluated by logistic regression analysis. Results: The diagnostic accuracy of ERR on panoramic images was 0.79 compared to CBCT images (P<0.05). Superimposition of M3s onto second molars (M2) was associated with an approximately 33 times higher risk of ERR than separated M3s(P<0.05). Impacted M3s showed a 5 times higher risk of ERR than erupted M3s(P<0.05). Conclusion: ERR related to M3s is a common clinical condition, and superimposition of M3 onto M2 on panoramic images was the most important risk factor for ERR. It seemed that CBCT examinations for maxillary M3s might be indicated for ERR diagnosis especially if panoramic radiographs show superimposition of M3 onto M2. Impaction itself was also a risk factor, and it should be carefully examined.

Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

  • Choi, Da-Hye;Choi, Bo-Ram;Choi, Jin-Woo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.43 no.1
    • /
    • pp.7-15
    • /
    • 2013
  • Purpose: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. Materials and Methods: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. Result: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Conclusion: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.

Investigation of the Super-resolution Algorithm for the Prediction of Periodontal Disease in Dental X-ray Radiography (치주질환 예측을 위한 치과 X-선 영상에서의 초해상화 알고리즘 적용 가능성 연구)

  • Kim, Han-Na
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 2021
  • X-ray image analysis is a very important field to improve the early diagnosis rate and prediction accuracy of periodontal disease. Research on the development and application of artificial intelligence-based algorithms to improve the quality of such dental X-ray images is being widely conducted worldwide. Thus, the aim of this study was to design a super-resolution algorithm for predicting periodontal disease and to evaluate its applicability in dental X-ray images. The super-resolution algorithm was constructed based on the convolution layer and ReLU, and an image obtained by up-sampling a low-resolution image by 2 times was used as an input data. Also, 1,500 dental X-ray data used for deep learning training were used. Quantitative evaluation of images used root mean square error and structural similarity, which are factors that can measure similarity through comparison of two images. In addition, the recently developed no-reference based natural image quality evaluator and blind/referenceless image spatial quality evaluator were additionally analyzed. According to the results, we confirmed that the average similarity and no-reference-based evaluation values were improved by 1.86 and 2.14 times, respectively, compared to the existing bicubic-based upsampling method when the proposed method was used. In conclusion, the super-resolution algorithm for predicting periodontal disease proved useful in dental X-ray images, and it is expected to be highly applicable in various fields in the future.

3차원 두부방사선 규격사진 구현시 컴퓨터를 이용한 두부위치의 보정방법에 관한 연구

  • Choy, Kwang-Chul;Kim, Kyung-Ho;Kim, In-Dal
    • The Journal of the Korean dental association
    • /
    • v.36 no.2 s.345
    • /
    • pp.135-143
    • /
    • 1998
  • Cephalogram is one of the most important tool in researching growth and development of craniofacial area, orthodontic diagnosis and treatment planning. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. three dimensional high quality images can be obtained using computerized tomogram and have reported in literatures. Considering its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. construction of three dimensional image using principle of orientator can be obtained by biplanar stereoradiography. Theoretically two images, lateral and P-A can be used to construct three dimensional image provided that those are taken at same time by two different focal spots. As two images(lateral and P-A) obtained by conventional cephalogram have different head posture, those need compensation to construct three dimensional images. This study introduced principle of computerized head posture compensation and showed that conventional cephalogram could be used to construct three dimensional image and could be applied to routine orthodontic practice.

  • PDF

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

Analysis of YouTube Content on Oral Disease Information about the Elderly

  • Kim, Ji-Won;Gu, Hanna;Kwon, Hye-Jin;Lim, Jeong-Hyun;Lim, Hee-Jung
    • Journal of dental hygiene science
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Background: The elderly have, a higher disease morbidity than other age groups due to a decrease in resistance to the disease and have complex diseases, so care should be taken. Accordingly, it is considered important to provide information for improving the health of the elderly. Health information plays an important role in individual health promotion and education, so the degree of exposure to information about oral health of the elderly is expected to have a significant impact on understanding and acquiring information on oral content videos on the importance, prevention, and management of oral health of the elderly in the future. Methods: This study analyzed video content related to oral diseases of the elderly in a total of 150 videos uploaded on YouTube from January 1, 2012 to May 13, 2021, using a total of three books of dental hygiene for the elderly. Results: Forty-nine broadcasters accounted for the most of this information. Among the information providers, there were two dental hygienists. They accounted for 1.3% of all the information providers. The highest number of dental hygienists who broadcasted information was 42 in 2019. The average number of views was 37,303 periodontal diseases, the highest. Among the videos, dry mouth was the most common with 34 oral diseases. Conclusion: The number of images for each disease varies, so it seems that information should be provided in various ways. Dental hygienists should widely improve oral health knowledge by providing various dental hygiene management images for each oral disease to improve the oral health of the general public. In addition, based on the information of the Health Insurance Review and Assessment Service, the development and provision of content should be actively carried out so that people can obtain the information they desire.