• 제목/요약/키워드: Dental images

검색결과 807건 처리시간 0.032초

Radiopacity of contemporary luting cements using conventional and digital radiography

  • An, Seo-Young;An, Chang-Hyeon;Choi, Karp-Sik;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.97-101
    • /
    • 2018
  • Purpose: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. Materials and Methods: Disc specimens (N=24, n=6 per group, ø$7mm{\times}1mm$) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Multilink (3.44-4.33) showed the highest radiopacity, followed by U-cem (1.81-2.88), Panavia F 2.0 (1.51-2.69), and Duolink (1.48-2.59). The $R^2$ values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. Conclusion: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.

안면비대칭 진단을 위한 하악골 3차원영상 계측기준치에 관한 연구 (A study on the 3-D standard value of mandible for the diagnosis of facial asymmetry)

  • 안정순;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제35권2호
    • /
    • pp.91-105
    • /
    • 2005
  • 기존의 2차원적 진단자료는 상의 확대 및 왜곡으로 인해 형태나 크기의 정량적 평가시 부적절한 결과를 야기할 수 있어 안면비대칭의 정확한 진단과 치료계획 수립을 위해서는 3차원영상 진단의 도입이 필요하다. 본 연구는 안면비대칭 진단시 3차원적 분석에 도움이 되는 기준자료를 얻고자 정상교합자를 대상으로 하악골 3차원 영상 계측항목의 평균값과 좌우차이의 정상범주를 알아보기 위하여 시행되었다 뚜렷한 안면비대칭을 보이지 않는 성인 정상교합자 남녀 30명씩 총 80명을 대상으로 두경부 전산화단층사진을 촬영한 후 컴퓨터프로그램을 이용한 각각의 단면 촬영영상 정보를 이용하여 3차원 입체영상을 재구성한 다음, 하악골 비대칭시 좌우차이를 보일 수 있는 계측항목으로 ramus length를 나타내는 5개 condylar neck length를 나타내는 1개, mandibular body length를 나타내는 8개 등 15개의 거리 계측항목과, gonial angle을 나타내는 4개. frontal ramal inclination을 나타내는 2개. lateral ramal inclination을 나타내는 2개 등 8개의 각도계측항목, 총 23개의 계측항목을 설정한 후, 좌측과 우측을 구분하여 컴퓨터 상에서 3차원계측치를 구하고 좌우차이값을 산출하였다. 본 연구결과 얻어진 정상교합자의 하악골 3차원영상 계측항목의 좌우차이값은 안면비대칭 환자의 진단 기준치로 유용하게 사용될 수 있을 것이다.

하악전돌자에서 3차원영상을 이용한 하악지시상분할골절단술과 관련된 하악골의 해부학적 연구 (MORPHOLOGIC STUDY FOR SAGITTAL SPLIT RAMUS OSTEOTOMY USING 3-D IMAGE IN MANDIBULAR PROGNATHISM)

  • 박충열;국민석;박홍주;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권4호
    • /
    • pp.350-359
    • /
    • 2005
  • Sagittal split ramus osteotomy(SSRO) has been commonly performed in the mandibular prognathism. The previous studies of the mandibular anatomy for SSRO have mostly been used in dry skull without consideration of age, sex or jaw relationship of patients. This study was performed to evaluate the location of mandibular canal and the anatomy of ramus, such as the location of mandibular lingula and the ramal bone marrow, which were associated with SSRO procedures, in the patients with mandibular prognathism and normal young adults by using computerized tomographs(CT) and 3D images. The young adults at their twenties, who were considered to complete their skeletal growth, and seen in the Department of Orthodontics and Oral and Maxillofacial Surgery in Chonnam National University Hospital between March 2000 and May 2003, were selected. This study was performed in 30 patients (15men, 15women) who were diagnosed as skeletal class I normal relationship, and another 30 patients (15men, 15women) who were diagnosed as skeletal class III relationship upon clinical examination and lateral cephalometric radiographs. The patients were divided into 2 groups : Class I group, the patients who had skeletal class Ⅰ normal relationship(n=30, 15men, 15women), and Class III group, the patients who had skeletal class III relationship(n=30, 15men, 15women). Facial CT was taken in all patients, and pure 3D mandibular model was constructed by V-works version 4.0. The occlusal plane was designed by three points, such as the mesiobuccal cusp of both mandibular 1st molar and the incisal edge of the right mandibular central incisor, and used as a reference plane. Distances between the tip of mandibular lingula and the occlusal plane, the sigmoid notch, the anterior and the posterior borders of ramus were measured. The height of ramal bone marrow from the occlusal plane and the distance between mid-point of mandibular canal and the buccal or lingual cortex of the mandible in the 1st and 2nd molars were measured by V-works version 4.0. Distance(Li-OP) between the occlusal plane and the tip of mandibular lingula of Class III Group was longer than that of Class I Group in men(p<0.01), but there was no significant difference in women between both groups. Distance(Li-SN) between the sigmoid notch and the tip of mandibular ligula of Class III group was longer than that of Class I Group in men(p<0.05), but there was no significant difference in women between both groups. Distance(Li-RA) between the anterior border of ramus and the tip of mandibular lingula of Class III Group was shorter than that of Class I Group in men and women(p<0.01). Distance(Li-RP) between the posterior border of ramus and the tip of mandibular lingula of Class III Group was slightly shorter than that of Class I Group in men(p<0.05), but there was no significant difference in women between both groups. Distance(RA-RP) between the anterior and the posterior borders of ramus of Class III Group was shorter than that of Class I Group in men and women(p<0.01). Longer the distance(SN-AN) between the sigmoid notch and the antegonial notch was, longer the vertical ramal length above occlusal plane, higher the location of mandibular lingula, and shorter the antero-posterior ramal length were observed(p<0.01). Height of ramal bone marrow of Class III Group was higher than that of Class I Group in men and women(p<0.01). Distance between mandibular canal and buccal cortex of Class III Group in 1st and 2nd lower molars was shorter than that of Class I Group in men and women (p<0.05 in 1st lower molar in men, p<0.01 in others). These results indicate that there are some anatomical differences between the normal occlusal patients and the mandibular prognathic patients, such as the anterior-posterior length of ramus, the height of ramal bone marrow, and the location of mandibular canal.

하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향 (The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible)

  • 진민주
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.379-388
    • /
    • 2002
  • 임플랜트의 성공을 위해서 정확한 방사선학적 검사는 가용골의 높이와 하악관의 위치를 평가하고 중요구조물의 손상을 방지하는데 있어 필수적이다. CT촬영법 중 영상재구성법을 이용한 방법(CT/MPR)은 하악관의 위치를 잘 보여준다. 치아에 평행한 협설 단면 (cross-sectional plane)을 얻기 위해서는 횡단면(axial plane)이 교합면과 평행하도록 해야 한다. 횡단면(axial plane)이 교합면과 평행하지 않으면 재구성된 협설 단면(cross-sectional plane)은 계획된 fixture의 방향과 각을 이루게 되어 그 fixture의 실제 dimension을 보여주지 못하게 된다. 협설단면(cross-sectional view)에서 측정한 가용골 높이가 실제 가용골 높이보다 너무 큰 경우, 수술시 하악관을 침범할 가능성이 있게 된다. 이 연구의 목적은 하악 임플랜트 CT 촬영시 횡단면이 임플란트를 위한 가용골 높이의 측정에 미치는 영향을 알아보는 것이다. 하악 대구치 부위의 임플랜트를 계획하고 radiographic stent를 만든 후 치과 방사사선과에서 하악 임플랜트 CT를 촬영한 40명의 환자, 45개 부위를 선택하였다. 임플랜트 CT의 central panoramic view에서 치조정과 하악관, stent를 tracing한 후, 치조정과 하악관간의 거리(available bone height, ABH)를 재구성된 협설단면상에서 측정하였다(uncorrected ABH). 다음으로, .stent 방향으로 그은 직선상에서 측정하였다(corrected ABH). 두 거리사이의 각을 측정하였다. 두 거리로부터 각각 fixture의 길이를 결정하였다. 연구 결과, 두 가용골의 높이간에는 제 1 대구치와 제 2 대구치에서 모두 유의성있는 차이를 보였다 (p<0.001). 차이가 1 mm 이상인 경우는 제 1 대구치에서 8.7%, 제 2 대구치에서 15.5% 였다. 차이가 2 mm 이상인 경우는 제 1 대구치에서 2.0%, 제 2 대구치에서 6.6%였다. 최대값은 제 1 대구치에서 2.5 mm, 제 2 대구치에서 2.2 mm 였다. 두 가용골의 높이차와 각과의 상관 관계는 제 1 대구치와 제 2 대구치에서 모두 양의 상관관계를 보였다. 상관 계수는 제 1 대구치에서 0.534, 제 2 대구치에서 0.728 였다. 제 2 대구치가 더 강한 양의 상관관계를 보였다. 두 가용골의 높이로부터 결정한 fixture의 길이가 일치하지 않는 경우는 제 1 대구치에서는 24.4%, 제 2 대구치에서는 28.9%였다.

기능적 부하 후 "Short Implant" 주변의 골 흡수에 대한 방사선학적 연구 (Study on the radiographic evaluation of marginal bone loss around short-length implant after functional loading)

  • 박영주;남정훈;노경록;연병무;유우근;이정원;안장훈;강태인;박미희
    • 대한치과의사협회지
    • /
    • 제48권8호
    • /
    • pp.615-620
    • /
    • 2010
  • Purpose: The short dental implant is considered as possible solution in the alveolar bone height deficient cases. The aim of this study was to evaluate clinical availability of short implants by measuring the marginal bone loss of short length implants and comparing with that of conventional length implants. Materials and Methods: The groups were composed of patients who had received at least one implant. The samples of this study were selected from patients who with functional loading after prosthetic treatment for 1 year follow up period. The implants with a length of 5.7 mm and 6mm were considered short. (Bicon Dental implants, USA). The experiment group was composed of $4.5{\times}6mm$, $5{\times}6mm$, $6{\times}5.7mm$ implants (total 18 implants were placed in 14 patients, 8 on maxilla, 10 on mandible). The control group was composed of $4.5{\times}8mm$, $5{\times}8mm$, $4.5{\times}11mm$, $5{\times}11mm$. All implants were selected only by implants placed on molar area. We evaluated marginal bone loss in radiographic images at baseline (implant loading) and 3, 6, 12 months after loading. Additionally, crown-to-implant ratio was evaluated, and marginal bone loss according to crown-to-implant ratio after functional loading was analyzed. Results: The short implant group had a mean marginal bone level of $-0.52{\pm}0.69mm$; the 8mm group, $-0.22{\pm}0.82mm$; and the II mm group, $-0.10{\pm}1.09mm$ after I year of functional loading. But significant differences were not detected between three groups at every follow-up period. Crown-to-implant ratio in short implant group was $1.55{\pm}0.23$; 8mm group was $1.15{\pm}0.18$; and 11mm group was $0.92{\pm}0.15$. Additionally, significant differences between three groups were founded. (P<.0001) The greatest marginal bone loss after 1 year follow-up was founded at crown-to-implant ratio 1~1.49 range in short implant. Conclusion: The marginal bone loss of short implants was comparable to that of long implants. So, the short implants can be a clinically acceptable option.

Stainless steel hand file과 Ni-Ti rotary file을 이용한 근관 형성시 근단부 근관 형태의 순차적 변화에 대한 평가 (Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography)

  • 이우진;이정호;전경아;서민석;유연지;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.231-237
    • /
    • 2011
  • 연구목적: 본 연구에서는 micro CT를 사용하여 SS K-file, Profile, LightSpeed로 #25부터 #40 크기까지 근관을 형성할 때 근단부 근관 형태의 연속되는 변화를 평가하였다. 연구 재료 및 방법: 30개 하악 대구치의 근심 근관을 ProFile, LightSpeed와 SS K-file로 #25번에서 #40번까지 순차적으로 근관 형성하였고, 매 단계 확대 후 micro CT를 시행하였다. 치근단 1, 2, 3, 5 mm 에서 근관 중심 변위와 삭제되지 않은 단면의 비율을 측정하여 'repeated nested design' 분석방법과 Mann-Whitney test로 유의 수준 p = 0.05에서 검정하였다. 결과: SS K-file군에서 #30 이상 근관 형성 후 유의할 만한 근관 중심 변위가 증가하였고, 근관 형성 과정 어느 단계에서도 삭제되지 않은 면적의 비율이 유의성 있게 감소되지 않았다. ProFile군에서는 치근단 1, 2 mm에서 #40 file로 근관 형성 후 근관 중심 변위가 크게 증가하였고, 치근단 1 mm에서 #35 크기로 근관 형성한 후에 삭제되지 않은 면적의 비율이 유의성 있게 감소하였다. LightSpeed군에서는 급격한 근관 중심 변위를 관찰할 수 없었고, 근관 중심 변위가 ProFile군보다 적게 관찰되었다. 결론: SS K-file, Profile, LightSpeed에서 형성되는 근관의 변이 정도는 근단부 근관 형성 크기에 따라 다르게 나타났다.

임플란트 식립 환자의 $PostPlant^{TM}$ Calcium 투여 효과에 대한 임상연구 (The efficacy evaluation of $PostPlant^{TM}$ Calcium in dental implant placement)

  • 최유성;김은경;김세원;조인호
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.128-134
    • /
    • 2010
  • 연구목적: 본 연구에서는 건강기능식품인 $PostPlant^{TM}$ Calcium을 임플란트 식립 환자에게 투여하고, 투여하지 않은 군과 비교하여 그 유효성과 안정성을 평가하여 투여 후 골밀도의 변화 및 골유착 기간의 단축 여부를 평가하고자 하였다. 연구 재료 및 방법 임플란트 식립 후에Post$PostPlant^{TM}$ Calcium을 투여한 실험군은 18명의 환자를 대상으로 25개의 임플란트를 식립하였고, 투여하지 않은 대조군에서는 7명의 환자에게 9개의 임플란트를 식립하여 관찰하였다. 일차수술 후, 이차수술 후, 6개월 후에 $Osstell^{TM}$ Mentor, $Periotest^{(R)}$를 이용하여 임플란트 안정성을 비교 분석하였고, 일차수술후, 1, 3, 6개월 후에 방사선 사진 촬영을 시행하여 임플란트 주위 골밀도를 측정하여 비교 분석하였다. 결과:1. $Osstell^{TM}$ Mentor의해 측정된 ISQ 값은 측정 결과 시간이 경과함에 따라 실험군, 대조군 모두 수치가 높아지는 경향을 보였다. 실험군의 측정값이 대조군에 비해 더 높은 수치를 보였으며, 식립 6개월 후에 실험군과 대조군 간에 통계적으로 유의한 차이가 관찰되었다 (P< .05); 2. $Periotest^{(R)}$ 측정 결과 시간이 경과함에 따라 실험군, 대조군 모두 수치가 낮아지는 경향을 보였으며, 실험군이 대조군에 비해 더 낮은 수치를 나타내었으나 각 군간에 통계적인 유의성은 없었다. 3. 골밀도 측정 결과 시간이 경과함에 따라 실험군, 대조군 모두 골밀도 수치가 증가하는 경향을 보였으며, 실험군이 대조군에 비해 더 높은 수치를 나타내었으나 각 군간에 통계적인 유의성은 없었다. 결론:임상적으로 임플란트 식립 후 환자가 $PostPlant^{TM}$ Calcium을 장기간 복용하는 것이 임플란트 안정성을 높이고, 골유착을 성공적으로 이루는데 도움을 줄 수 있다고 사료된다.

미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구 (LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY)

  • 이혁상;김영재;김정욱;장기택
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.498-503
    • /
    • 2006
  • 글라스 아이오노머 시멘트는 초기 우식 치질의 재광화 효과가 있다고 알려져 있다. 본 연구에서는 세 가지 종류의 시판되고 있는 글라스 아이오노머 시멘트(Fuji IX GP, Vitremer, F2000)를 실험군으로, 컴퍼짓트 레진(Filtek Z250)을 대조군으로 사용하여 9개월간 인접면 우식증에 대한 재광화 효과를 시편의 파괴 없이 3개월 간격으로 미세전산화 단층촬영으로 시편의 상을 얻고, 이렇게 얻은 상을 3차원으로 재구성하고 우식 부위의 미세밀도의 변화를 측정하여 재광화 정도를 평가하였다. 인접면 수복물은 인공 우식 병소가 있는 치아 시편과 수복 재료(세가지 글라스 아이오노머 및 컴퍼짓트 레진)를 접촉시켜 재현하였고, 이것을 인공 타액에 완전히 잠기도록 하여 pH 7.0, $37^{\circ}C$를 유지하였다. 치아 시편들은 실험 시작 후 90, 180, 270일 뒤에 꺼내어 미세 전산화 단층 촬영을 시행하였다. 얻어진 영상을 $Vworks^{TM}$ 4.0(CyberMed, Korea)을 사용하여 각 시편의 미세 밀도 값을 얻어낸 후, 각 군에서 얻어진 값은 SPSS 11판을 사용하여, one-way ANOVA로 분석하고, post HOC Tukey multiple comparison test로 검증을 시행하였다. 그 결과 모든 군에서 병소의 밀도가 증가하였으며, 매 3개월마다 실험군의 평균 밀도 증가량은 대조군의 평균 밀도 증가량과 비교하여 유의하게 높았다(P<0.05)또한 실험군 간의 밀도 증가는 통계적인 유의 차가 없었다. 이번 실험의 의의는 기존의 연구 방법으로 알려져 있던 글라스 아이오노머의 초기 우식병소 재광화 효과를 보다 시각적이고 객관적인 방법으로 검증했다는 점과 우식 병소의 재광화 효과의 연구에 사용될 수 있는 새로운 연구 방법을 제시한 점에 있다.

  • PDF

과두간 폭경과 상악 제1대구치간 폭경 사이의 관계 (Relationship between inter-condylar width and inter-maxillary first molar width)

  • 오상천;공현준
    • 구강회복응용과학지
    • /
    • 제35권4호
    • /
    • pp.214-219
    • /
    • 2019
  • 목적: 본 연구의 목적은 상악과 하악의 완전 무치악 환자에서 보철물로 상실된 치열궁 폭경 재건을 위한 기준을 제시하기 위하여 과두간 폭경에 대한 상악 제1대구치간 폭경의 상관관계를 평가하기 위함이다. 연구 재료 및 방법: 콘빔형 전산화단층영상(Cone-beam CT)을 촬영한 환자 중, 본 연구의 기준에 부합하는 한국인 120명(남성 60명, 여성 60명)을 선택하였으며 Invivo 5.1을 이용해 Cone-beam CT scan을 분석하였다. 축의 방향설정 후, 상악 제1대구치의 근심 협측 교두정간 거리를 측정하였으며, 과두간 폭경은 각 과두의 중심점을 지정하여 측정하였다. 수집된 자료는 SPSS Version 20.0으로 분석하였고, Pearson의 상관분석을 이용하여 과두간 폭경과 상악 제1대구치간 폭경의 상관관계의 통계적 유의성을 검증하였다. 결과: 한국인의 평균 과두간 폭경은 105.9 mm였으며, 남성이 108.3 mm 여성이 103.4 mm였다. 평균 상악 제1대구치간 폭경은 57.1 mm였으며, 남성이 57.9 mm 여성이 56.2 mm였다. 과두간 폭경과 상악 제1대구치간 폭경에 대한 Pearson의 상관분석 결과, 0.614의 Pearson 상관계수로 통계적으로 유의한 양의 상관관계를 보였다. 결론: 과두간 폭경과 상악 제1대구치간 폭경은 양의 상관관계를 보였으며, 한국인의 과두간 폭경과 상악 제1대구치간폭경의 평균 비율은 1:0.54를 보였다. 본 제한된 연구의 결과를 근거로 상악과 하악의 완전 무치악 환자에서 과두간 폭경을 본래의 상악 치열궁 폭경 설정을 위한 가이드로서 사용이 가능할 것이다.

제1대구치 위치에 식립된 단일 임플란트의 지대주 연결 유형에 따른 임플란트 주위골 흡수 (Marginal bone loss between internal- and external- abutment connection type implants placed in the first molar area)

  • 이석현;이은우;정하나;김옥수
    • 구강회복응용과학지
    • /
    • 제39권1호
    • /
    • pp.32-44
    • /
    • 2023
  • 목적: 이번 연구는 상·하악 제1대구치 부위에 식립 된 단일 임플란트를 통해 임플란트-지대주 연결 유형이 임플란트의 변연골 소실 (MBL)에 영향을 주는지, 그리고 MBL에 영향을 끼치는 요인들을 알아보기 위해 분석하였다. 연구 재료 및 방법: 5년 이상의 추적 기간 동안, 상·하악 제1대구치 부위에 단일 임플란트를 식립하여 수복한 68명의 환자(남: 38명, 여: 30명)의 87 임플란트(external connection type (EC) 임플란트: 57개, internal connection type (IC) 임플란트: 30개)를 대상으로 추적 조사하였다. 최대 5년 후의 구내 방사선 영상에서 MBL과 보철물의 출현 각도(EA)를 측정하였다. 60 - 79세에 해당하는 환자의 비율이 52.9%로 가장 높았고 상악 구치부에 임플란트가 가장 많이 식립되었다. 결과: GBR을 하지 않은 경우 EC (-0.065 ± 0.859 mm)와 IC (-0.627 ± 0.639 mm)에서 유의한 차이가 있었고, 또한 당뇨병이 없는 환자들 사이에서 EC (-0.131 ± 1.002 mm)와 IC (-0.792 ± 0.762 mm)에서 유의한 차이가 존재하였다. 임플란트 매식체의 직경, 길이, 보철물 연결 방법, 임플란트 제조업체, 보철물의 emergence angle (EA)로 구분하였을 때 각군 간에 유의미한 차이가 없었다. 다중회귀분석을 이용하여 MBL에 영향을 주는 요인분석 결과 회귀계수의 유의성 검증에서 임플란트-지대주 체결 방식(β = -0.303), 당뇨병의 유무(β = -0.113), EA의 차이(β = -0.234), 나이(β = -0.776)에서 MBL에 통계학적으로 유의한 음의 상관관계를 보였다. 결론: IC가 EC보다 GBR을 하지 않은 경우와 당뇨병이 없는 환자들 사이에서 MBL이 작다는 것을 알 수 있었다. 또한 보철물의 EA가 30°보다 큰 보철물의 형태를 가진 임플란트가 30°보다 작은 보철물의 형태를 가진 임플란트 보다 MBL이 컸으며 나이가 많을수록 MBL이 크다는 것을 알 수 있었다. 임플란트의 MBL을 최소화하고 임플란트 안정성을 확보하기 위해서 임플란트 보철물의 EA와 임플란트-지대주 연결 유형을 세심하게 고려해야 할 것이다.