• Title/Summary/Keyword: Dental images

Search Result 809, Processing Time 0.028 seconds

Assessment of apical root resorption using digital subtraction radiography (디지털공제방사선촬영술을 이용한 치근단 흡수의 평가)

  • Heo Min-Suk;Lee Sam-Sun;Lee Kyung-Hee;Choi Hang-Moon;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.51-55
    • /
    • 2001
  • Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.

  • PDF

A Study on Automatic Tooth Root Segmentation For Dental CT Images (자동 치아뿌리 영역 검출 알고리즘에 관한 연구)

  • Shin, Seunghwan;Kim, Yoonho
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.4
    • /
    • pp.45-60
    • /
    • 2014
  • Dentist can obtain 3D anatomical information without distortion and information loss by using dental Computed Tomography scan images on line, and also can make the preoperative plan of implant placement or orthodontics. It is essential to segment individual tooth for making an accurate diagnosis. However, it is very difficult to distinguish the difference in the brightness between the dental and adjacent area. Especially, the root of a tooth is very elusive to automatically identify in dental CT images because jawbone normally adjoins the tooth. In the paper, we propose a method of automatically tooth region segmentation, which can identify the root of a tooth clearly. This algorithm separate the tooth from dental CT scan images by using Seeded Region Growing method on dental crown and by using Level-set method on dental root respectively. By using the proposed method, the results can be acquired average 19.2% better accuracy, compared to the result of the previous methods.

Comparison of different radiographic methods for the detection of the mandibular canal

  • Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.33 no.4
    • /
    • pp.199-205
    • /
    • 2003
  • Purpose: To compare the visibility of the mandibular canal at the different radiographic methods such as conventional panoramic radiographs, Vimplant multi planar reformatting (MPR)-CT panoramic images, Vimplant MPR-CT paraxial images and film-based DentaScan MPR-CT images. Materials and Methods: Data of 11 mandibular dental implant patients, who had been planned treatment utilizing both panoramic and MPR-CT examination with DentaScan software (GE Medical systems, Milwaukee, USA), were used in this study. The archived axial CT data stored on CD-R discs were transferred to a personal computer with 17' LCD monitor. Paraxial and panoramic images were reconstructed using Vimplant software (CyberMed Inc., Seoul, Korea). Conventional panoramic radiographs, monitor-based Vimplant MPR-CT panoramic images, monitor-based Vimplant MPR-CT paraxial images, and film-based DentaScan MPR-CT images were evaluated for visibility of the mandibular canal at the mental foramen, 1 cm, 2 cm, and 3 cm posterior to mental foramen using the 4-point grading score. Results: Vimplant MPR-CT panoramic, paraxial, and DentaScan MPR-CT images revealed significantly clearer images than conventional panoramic radiographs. Particularly at the region 1 em posterior to mental foramen, conventional panoramic radiographs showed a markedly lower percentage of 'excellent' mandibular canal images than images produced by other modalites. Vimplant MPR-CT and DentaScan MPR-CT images did not show significant difference in visibility of the mandibular canal. Conclusion: The study results show that Vimplant and DentaScan MPR-CT imaging systems offer significantly better images of the mandibular canal than conventional panoramic radiograph.

  • PDF

Teleradiology in Oral and Maxillofacial Radiology (영상치의학 분야에서의 원격판독)

  • Kim, Jo-Eun
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.729-733
    • /
    • 2016
  • Teleradiology is the electronic transmission of radiologic images from one location to another for the purpose of interpretation and/or consultation. Today, images can be easily transmitted to another location using the high-speed internet. In medical area, teleradiology has developed rapidly in recent 10 years due to the imbalance between the demand and availability of diagnostic services. However, teleradiology in dentistry is still inactive. I would like to overview the current teleradiology system, and discuss the necessity and the potentiality.

  • PDF

A Study on the Image of Dental Hygienists in Dental Patients and Caregivers (치과환자 및 보호자가 인지한 치과위생사 이미지)

  • Kang, Boo-Wol
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.197-211
    • /
    • 2007
  • The purpose of this study was to examine the image of dental hygienists. The subjects in the study were 396 patients and their caregivers who visited 14 dental hospitals and dentists' offices in and around Seoul. After a survey was conducted, the following findings were given: 1. The people investigated gave a mean of 4.0 to the image of dental hygienists. Dental hygienists rated highest in terms of looking neat and tidy(4.33), and were given the lowest marks in arbitrary job performance(3.46). 2. There appeared four different types of dental hygienist images, which made a 59.824 prediction of the image of dental hygienists in general. A typical image(4.11) was most dominant, followed by professional one(4.07), personal one(4.01) and social one(3.73). 3. The relations between the general characteristics of the respondents and their image of dental hygienists could be described as below: 1) By age, those who were in their 60s(4.12) had the best image of dental hygienists, and the teenagers(3.90) had the worst image of them. 2) By gender, the men(4.05) looked at dental hygienists more positively than the women(3.96). They had a significantly different opinion on the social image of dental hygienists according to gender(pE0.05). 3) By marital status, the married people(4.00) had a better image of dental hygienists than the unmarried ones(3.95). 4) As for the influence of the type of dental institutions, they had a more favorable image of dental hygienists in dentists' offices(4.13) than in dental hospitals(3.88). There was a broad significant difference in the way they looked at the professional and personal images of dental hygienists according to the type of dental institutions(pE0.001). 5) As to the impact of educational level, those who received community-college or higher education(4.01) had the best image of dental hygienists, and those who received middle-school or lower education(3.91) had the worst image of them. 6) By occupation, the government workers and students(4.07) had the best image of dental hygienists, and the company employees(3.90) had the worst image of them. They took a significantly different view of the social image of dental hygienists according to occupation(pE0.05). 7) Concerning the impact of the frequency of receiving dental treatment, the respondents who had received it seven times or more(4.16) had the best image of dental hygienists, and those who hadn't(3.79) the worst image of them. There was a wide significant gap according to that frequency. The way they looked at the typical, social and professional images of dental hygienists was quite different significantly according to that frequency as well(pE0.001). 8) As for the influence of whether they were accompanied by caregivers or not, the people who weren't accompanied by caregivers(3.99) had a better image of dental hygienists than those who were(3.97).

  • PDF

Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Lopes, Sergio Lucio Pereira de Castro;Haiter-Neto, Francisco;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.339-346
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

A clinical pilot study of jawbone mineral density measured by the newly developed dual-energy cone-beam computed tomography method compared to calibrated multislice computed tomography

  • Kim, Hyun Jeong;Kim, Ji Eun;Choo, Jiyeon;Min, Jeonghee;Chang, Sungho;Lee, Sang Chul;Pyun, Woong Beom;Seo, Kwang-Suk;Karm, Myong-Hwan;Koo, Ki-Tae;Rhyu, In-Chul;Myoung, Hoon;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.295-299
    • /
    • 2019
  • Purpose: This clinical pilot study was performed to determine the effectiveness of dual-energy cone-beam computed tomography (DE-CBCT) in measuring bone mineral density (BMD). Materials and Methods: The BMD values obtained using DE-CBCT were compared to those obtained using calibrated multislice computed tomography (MSCT). After BMD calibration with specially designed phantoms, both DE-CBCT and MSCT scanning were performed in 15 adult dental patients. Three-dimensional (3D) Digital Imaging and Communications in Medicine data were imported into a dental software program, and the defined regions of interest (ROIs) on the 3-dimensional surface-rendered images were identified. The automatically-measured BMD values of the ROIs (g/㎤), the differences in the measured BMD values of the matched ROIs obtained by DE-CBCT and MSCT 3D images, and the correlation between the BMD values obtained by the 2 devices were statistically analyzed. Results: The mean BMD values of the ROIs for the 15 patients as assessed using DE-CBCT and MSCT were 1.09±0.07 g/㎤ and 1.13±0.08 g/㎤, respectively. The mean of the differences between the BMD values of the matched ROIs as assessed using DE-CBCT and calibrated MSCT images was 0.04±0.02 g/㎤. The Pearson correlation coefficient between the BMD values of DE-CBCT and MSCT images was 0.982 (r=0.982, P<0.001). Conclusion: The newly developed DE-CBCT technique could be used to measure jaw BMD in dentistry and may soon replace MSCT, which is expensive and requires special facilities.

CT evaluation of underlying bone sclerosis in patients with oral squamous cell carcinoma: A preliminary retrospective study

  • Jo, Gyu-Dong;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul;Huh, Kyung-Hoe
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.255-259
    • /
    • 2017
  • Purpose: Underlying bone sclerosis is frequently observed in clinical settings when oral squamous cell carcinoma (OSCC) invades the jaw bone. The aim of this study was to assess the prevalence and characteristics of underlying bone sclerosis in patients with OSCC. Materials and Methods: We retrospectively reviewed the computed tomographic (CT) images of 131 patients who underwent mandibulectomy between January 2012 and December 2015 to treat OSCC. The presence, degree, and extent of underlying bone sclerosis were assessed on CT images and correlated with the following imaging patterns of bone invasion: cortical invasion, medullary invasion with a smooth margin, and medullary invasion with an irregular margin. The chi-square test was used to determine the relationships between the variables. Results: The prevalence of underlying bone sclerosis on CT images was 70.1% (47 of 67). The prevalence was 85.7% (42 of 49) in patients with medullary invasion, but it was 27.8% (5 of 18) in patients with only cortical invasion, indicating a significant increase in the prevalence of underlying bone sclerosis in patients with medullary invasion (P<.05). Aggressive patterns of bone invasion were associated with increases in the degree and extent of the underlying bone sclerosis(P<.05). Conclusion: More than two-thirds of OSCC cases with bone invasion showed underlying bone sclerosis. On CT images, reactive sclerosis in the remaining margin of the alveolar bone should not be used as the primary means to differentiate periodontal inflammatory lesions from those resulting from OSCC.

Image characteristics of cone beam computed tomography using a CT performance phantom (CT performance phantom을 이용한 cone beam형 전산화단층영상의 특성)

  • Han, Choong-Wan;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.157-163
    • /
    • 2007
  • Purpose: To evaluate the characteristics of (widely used) cone beam computed tomography (CBCT) images. Materials and Methods: Images were obtained with CT performance phantoms (The American Association of Physicists in Medicine; AAPM). CT phantom as the destination by using PSR $9000N^{TM}$ dental CT system (Asahi Roentgen Ind. Co., Ltd., Japan) and i-CAT CBCT (Imaging Science International Inc., USA) that have different kinds of detectors and field of view, and compared these images with the CT number for linear attenuation, contrast resolution, and spatial resolution. Results: CT number of both PSR $9000N^{TM}$ dental CT system and i-CAT CBCT did not conform to the base value of CT performance phantom. The contrast of i-CAT CBCT is higher than that of PSR $9000N^{TM}$ dental CT system. Both contrasts were increased according to thickness of cross section. Spatial resolution and shapes of reappearance was possible up to 0.6 mm in PSR $9000N^{TM}$ dental CT system and up to 1.0 mm in i-CAT CBCT. Low contrast resolution in region of low contrast sensitivity revealed low level at PSR $9000N^{TM}$ dental CT system and i-CAT CBCT. Conclusion: CBCT images revealed higher spatial resolution, however, contrast resolution in region of low contrast sensitivity was the inferiority of image characteristics.

  • PDF

A study on the Image for Dental Hygienists and Influence Factor in Academic High School Students (일부지역 인문계 고등학생의 치과위생사 이미지 및 영향요인 분석)

  • Han, Ok-Sung;Chung, Kyung-Yi
    • Journal of Digital Convergence
    • /
    • v.15 no.2
    • /
    • pp.385-392
    • /
    • 2017
  • The aim of this study was to examine the image for dental hygienists and influence factor in academic high school students. A self-reported questionnaire was surveyed by 211 high school student in G area. the data were analyzed for frequency analysis, average, standard deviation, independent t-test, one-way ANOVA, pearson's correlation coefficient by using SPSS 21.0 program. In case of general high-school students, occupational and business images were higher significantly. The social images were higher significantly in case of having introduction or explanation for dental hygienists. In addition, the self-esteem showed significant differences depending on the oral condition. There were positive correlations among the occupational, business, personal, social images of dental hygienists and self-esteem. Multiple regression analysis showed that highest in occupational images.