• Title/Summary/Keyword: Dental images

Search Result 816, Processing Time 0.033 seconds

Magnetic Resonance Imaging of the Temporomandibular Joint (측두하악관절의 핵자기공명영상 촬영에 관한 연구)

  • Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.407-410
    • /
    • 1999
  • Purpose; To find out the best imaging parameters for the diagnosis of disc in MRI imaging. Materials and methods; The diagnostic quality of the disc among the Tl, PD and T2 images of same patients02 joints, 223 images) was compared by visual(I-IV grades) and gray level measurement (pre- and infra-discal area) method. Results; PD images showed best results with 43.7% of the images belonging to grade III (good) and with statistically significant higher difference of the gray levels at pre- and infra-discal areas. But there were no grade N (excellent) images. Conclusions; PD images are best method among Tl. PD and T2 images in diagnosing the disc but since there were no excellent images further imaging parameters should be studied for better images.

  • PDF

Detectability of Ektaspeed Plus Film, Digitized and Digora Images for Artificial Periapical Bone Lesions (Ektaspeed Plus 방사선사진, 간접 디지털 영상 및 Digora 영상의 치근단 병소의 판독능 비교)

  • Cho Bong-Hae;Nah Kyung-Soo;Lee Hee-Joo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.461-470
    • /
    • 1998
  • The comparative detectability of the artificial periapical defects among Ektaspeed Plus film. digitized and digora images was evaluated. The artifical defects were made in the cancellous bone and cancellous-cortical junction with the size of 1.0×0.8mm², 1.4×1.1mm² and 2.8×2.2mm². The defects in cancellous-cortical junction extended into cortical bone with the depth of 0, 0.5 and 1.0 mm. The results were as follows : 1. In junctional defects Ektaspeed Plus film for 2.8×12.2mm² defect showed the highest detectability. But significant difference were only found between Ektaspeed Plus films and digitized images (p<0.05). 2. Almost all defects within cacellous bone were not detected except a few digitized and Digora images for the size of 2.8×2.2mm². Digora images for them showed significant differences with Ektaspeed Plus films and digitized images (p<0.05). 3. The sensitinity of all imaging modalities were 0.9 or 1.0 in junctional defects for the size of 1.4×2.2mm² and 2.8×2.2mm². For cancellous defects, Digora image showed the highest sensitivity of 0.6 for the size of 2.8×2.2mm². 4. Significant differences for change of exposure time were found in most group of Ektaspeed Plus films and digitized images (p<0.05) . But there was no significant differences in Digora images for cacellous defects.

  • PDF

An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

  • Kim, Hyun Jin;Kim, Hyun Nam;Raza, Hamid Saeed;Park, Han Beom;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.799-804
    • /
    • 2016
  • A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques (위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발)

  • Oh, Yun-Jung;Hwang, In-Nam;Park, Su-Jung;Im, Kwang-Hee;Cho, Hyun-Joon;Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error (중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

Intraosseous neurofibroma of the mandible involving masticator space (저작근 공간을 침범한 하악골내 신경섬유종)

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Kim, Hak-Sun
    • The Journal of the Korean dental association
    • /
    • v.58 no.9
    • /
    • pp.556-562
    • /
    • 2020
  • Neurofibroma is a benign, heterogenous peripheral nerve sheath tumor arising from the connective tissue of peripheral nerve sheaths, especially the endoneurium. Its intraoral occurrence is uncommon and its occurrence within mandible is extremely rare. A case of solitary intraosseous neurofibroma of the mandible involving masticator space in a 8-year-old male is reported. He was referred from a private local clinic with a chief complaint of limitation in opening of the mouth. Panoramic and cone-beam computed tomographic images showed unilocular radiolucent lesion with scalloped border at the right mandibular ramus, connected posteriorly to the enlarged mandibular foramen and anteriorly to the mandibular canal. T1-weighted magnetic resonance images showed soft tissue mass of isointensity compared with muscles. Contrast-enhanced T1-weighted images showed peripheral enhancement and T2-weighted images showed the heterogeneous hyperintense mass with extension between lateral and medial pterygoid muscles. The tumor was surgically removed under general anesthesia and diagnosed to be neurofibroma at the biopsy.

  • PDF

A COMPARATIVE STUDY OF ANATOMIC STRUCTURES ON THE PANORAMIC RADIOGRAPH AND SOME EXTRAORAL RADIOGRAPHS (파노라마방사선사진상과 구외방사선사진상에서의 해부학적 구조에 관한 비교연구)

  • Lee Dong Kyu;Kim Han Pyoung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.71-80
    • /
    • 1984
  • The author has studied each landmark for successful interpretation in the radiograph of the head that have the complex anatomic structures, using panoramic radiograph, postero-anterior cephalometric radiograph, lateral cephalometric radiograph, Waters' radiograph of the skull. The anatomic structures of the human dry skull attached by radiopaque materials were taken radiographs and analysed comparatively. The results were as follows: 1. The overall anatomic structures of the mandible showed sharp images in the panoramic radiograph than other radiographs with relatively less distortion, superimposition, blurring of the image. 2. The anatomic structures were situated on sagital plane of the skull showed blurred images in panoramic radiograph than other radiographs. 3. The anatomic structures which were situated on the basal portion of the skull showed blurred and secondary images in the panoramic radiograph than other radiographs. 4. In the panoramic radiograph, the lower 3rd portion of the orbit appeared to be superimposed with the superior portion of the maxillary sinus and the medial and lateral surface of the nasal cavity showed extensively superimposition of the orbit and the maxillary sinus, which images showed blurring. 5. The inferior surface and posterior surface of maxillary sinus showed to be good image in the panoramic radiograph than other radiographs. 6. In the panoramic radiograph, line of maxillary bone between lateral pterygoid plate, line of maxillary bone between zygomatic bone showed distinct image with another structures.

  • PDF

Clinical applications and performance of intelligent systems in dental and maxillofacial radiology: A review

  • Nagi, Ravleen;Aravinda, Konidena;Rakesh, N;Gupta, Rajesh;Pal, Ajay;Mann, Amrit Kaur
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.81-92
    • /
    • 2020
  • Intelligent systems(i.e., artificial intelligence), particularly deep learning, are machines able to mimic the cognitive functions of humans to perform tasks of problem-solving and learning. This field deals with computational models that can think and act intelligently, like the human brain, and construct algorithms that can learn from data to make predictions. Artificial intelligence is becoming important in radiology due to its ability to detect abnormalities in radiographic images that are unnoticed by the naked human eye. These systems have reduced radiologists' workload by rapidly recording and presenting data, and thereby monitoring the treatment response with a reduced risk of cognitive bias. Intelligent systems have an important role to play and could be used by dentists as an adjunct to other imaging modalities in making appropriate diagnoses and treatment plans. In the field of maxillofacial radiology, these systems have shown promise for the interpretation of complex images, accurate localization of landmarks, characterization of bone architecture, estimation of oral cancer risk, and the assessment of metastatic lymph nodes, periapical pathologies, and maxillary sinus pathologies. This review discusses the clinical applications and scope of intelligent systems such as machine learning, artificial intelligence, and deep learning programs in maxillofacial imaging.

Diagnostic Imaging of Pigmented Villonodular Synovitis of the Temporomandibular Joint. (측두하악관절에 발생한 색소성 융모결절성 활막염(Pigmented Villonodular Synovitis)의 영상진단)

  • Song Man-Yong;Lee Kyung-Hee;Lee Sang-Chul;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.505-519
    • /
    • 1998
  • The occurrence of PVNS in the TMJ is very rare. We report a case of PVNS which was misdiagnosed as a parotid tumor at first. CT and conventional radiograph revealed a well defined mass demonstrating higher attenuation than adjacent soft tissue. Erosion and expansion of the cortical plate of the mandibular condyle and sclerotic change beneath the margin of the lesion were also shown. MRI demonstrated well defined mass of very low signal intensity on both Tl and T2-weighted images due to ferromagnetic effect of the high concentrated hemosiderin and clearly delineated the extent of the lesion. Histopathologic findings and characteristic appearance of the various imaging methods were described and the usefulness of these images for diagnosis and pretreatment evaluation of PVNS were also discussed.

  • PDF

Trifid mandibular canal in Cone-Beam CT : A case report (CBCT에서 관찰되는 trifid mandibular canal)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.56 no.2
    • /
    • pp.113-119
    • /
    • 2018
  • Trifid mandibular canal (TMC) is one of the anatomical variation of mandibular canal with clinical importance. An extra mandibular canal may explain inadequate anesthesis and be damaged causing paresthesia or bleeding during mandibular surgery. CBCT with high-level spatial resolution is an useful tool for the detection of mandibular canal and its variation. The aim of this report is to present a case of trifid mandibular canal with CBCT images and to give information on this anatomical variation of mandibular canal.

  • PDF