• Title/Summary/Keyword: Dental error

Search Result 191, Processing Time 0.024 seconds

A Study on the Accuracy of Dental Abutments Manufactured by the Dental CAD/CAM Round Bar Milling Method and CNC Milling Machine (치과용 CAD/CAM 환봉밀링 방식과 CNC 밀링기를 통해 제작된 치과용 어버트먼트의 적합 정밀도 분석)

  • JUNG SOOK KIM
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.67-71
    • /
    • 2023
  • Recently, the method of making a dental prothesis is changed in the ICT based digital way. In particular, with the emergence of the CAD/CAM or 3D printing for dental purpose, a computer based digital type is selected gradually more than an analog type. To make an implant abutment, it is possible to apply the conventional technique of making round bars, or the technique using a CNC milling machine. This study tested these two types of the techniques to find which one had more precision and a smaller error when the margin and occlusal surface was made. According to the test, the technique using a CNC milling machine to make an implant abutment had a small error and supported precise processing in terms of the margin fit and the occlusal surface. Therefore, it was found to be useful in making a custom-made prothesis.

Strategies for dental aspiration and ingestion accidents that can lead to serious complications: a report of three cases and a review of articles

  • Shin, Youngjin;Hong, Sung ok;Kim, Rayeon;Jee, Yu-jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.5
    • /
    • pp.318-325
    • /
    • 2022
  • Population aging and the usage of small devices in implant prosthetic procedures have led to many incidents of dental aspiration and ingestion. Various preventive measures have been introduced to prevent these accidents. However, accidents can occur at any time. Dental aspiration and ingestion lead to fatal consequences if the issue is not promptly and appropriately dealt with. Preparing a collaborative system for dealing with accidents before they occur can prevent further sequelae. This study involves ingestion and aspiration accidents that occurred during dental treatment: two ingestion cases and one aspiration case. All dental foreign bodies were removed according to the guidelines presented in our review. With the cooperation of other medical departments, the issues were quickly resolved. Simple and accurate protocols should be provided to all dentists and dental staff to respond to such dental emergencies. In addition, collaboration among other medical departments should be established before any accidental ingestion and aspiration events occur.

The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices

  • Mahshid, Minoo;Saboury, Aboulfazl;Sadr, Seyed Jalil;Fayyaz, Ali;Kadkhodazadeh, Mahdi
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.5
    • /
    • pp.221-226
    • /
    • 2013
  • Purpose: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (${\pm}10%$ of the target torque) of spring-style mechanical torque devices (S-S MTDs). Methods: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). Results: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. Conclusion: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs.

Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner

  • Jeon, Jin-Hun;Kim, Dong-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.214-218
    • /
    • 2016
  • PURPOSE. We assessed the repeatability and reproducibility of abutment teeth dental impressions, digitized with a blue light scanner, by comparing the discrepancies in repeatability and reproducibility values for different types of abutment teeth. MATERIALS AND METHODS. To evaluate repeatability, impressions of the canine, first premolar, and first molar, prepared for ceramic crowns, were repeatedly scanned to acquire 5 sets of 3-dimensional data via stereolithography (STL) files. Point clouds were compared and the error sizes were measured (n=10, per type). To evaluate reproducibility, the impressions were rotated by $10-20^{\circ}$ on the table and scanned. These data were compared to the first STL data and the error sizes were measured (n=5, per type). One-way analysis of variance was used to assess the repeatability and reproducibility of the 3 types of teeth, and Tukey honest significant differences (HSD) multiple comparison test was used for post hoc comparisons (${\alpha}=.05$). RESULTS. The differences with regard to repeatability were 4.5, 2.7, and $3.1{\mu}m$ for the canine, premolar, and molar, indicating the poorest repeatability for the canine (P<.001). For reproducibility, the differences were 6.6, 5.8, and $11.0{\mu}m$ indicating the poorest reproducibility for the molar (P=.007). CONCLUSION. Our results indicated that impressions of individual abutment teeth, digitized with a blue light scanner, had good repeatability and reproducibility.

Safety of chloral hydrate sedation in dental practice for children: an overview

  • Song, Sol;Han, Miran;Kim, Jongbin
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.3
    • /
    • pp.107-118
    • /
    • 2020
  • Chloral hydrate is the oldest and most common sedative drug used in moderate sedation for pediatric dental patients. Hence, the purpose of this article is to review the safety and possible adverse events of this drug when used for pediatric dental treatment. A bibliographic search in PubMed, MEDLINE, Cochrane Library and KMbase, KISS, DBpia, KoreaMed, and RISS databases was performed. Using the keywords "dental sedation," "chloral hydrate," and "children or adolescent," 512 scientific articles were found. Subsequently, 183 studies were individually assessed for their suitability for inclusion in this literature review. Altogether, 24 studies were selected. They included 12 cases of death before, during, or after chloral hydrate sedation for dental treatment, majorly due to dosing error and use of multiple sedatives. Additionally, intraoperative adverse events were mostly respiratory problems such as hypoxia and apnea, but most events were temporary. After treatment, prolonged sedation, including excessive sleep and less activity were the most common postoperative adverse events, and even death cases were reported. Despite the wide acceptance of chloral hydrate as a sedative-hypnotic agent, the risk of adverse events and adequate dose should be of great concern when using it for pediatric dental sedation.

Perception of infection control activities and patient safety culture among dental hygienists (치과위생사의 감염관리활동과 환자안전문화에 대한 인식)

  • Choi, Eun-Mi;Noh, Hie-Jin;Chung, Won-Gyun;Mun, So-Jung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.5
    • /
    • pp.769-777
    • /
    • 2017
  • Objectives: The study was to promote patient safety by analyzing the effect of dental hygienist's perception of patient safety culture on infection control activities. Methods: The study is based on a survey of 377 dental hygienists in total working in dental settings. The questionnaire consisted of 119 questions, including 34 questions on perception of patient safety culture, and 85 questions on infection control activities. Hierarchical regression analysis was used to examine the relationship between the perception of patient safety culture and infection control activities. The data was analyzed using the SPSS version 20.0, and p<0.05 was adopted to decide on significance. Results: The longer dental hygienists have worked n the dental settings, the more active they become in infection control activities. Among the different types of dental care settings, general (university) hospitals had the largest number of infection control activities, followed by dental clinics, and network dental clinics, in descending order. The dental settings possessing a higher number of dental hygienists were found to conduct more infection control activities than other dental settings. In addition, it was found that when a dental setting adopts a patient safety policy across all the units in the hospital, more systems and procedures for patient safety tend to be established, and that stricter management response to error leads to improvement of infection control activities. Conclusions:In order to enhance infection control activities, infection control activity programs should develop and implement periodic reinforcement of infection control education. regular monitoring of infection control activities.

An Optimization of Restoration Method at Class V Lesion of a Finite Element Tooth Model (5급 병소가 있는 치아 유한요소 모델의 수복방법 최적화)

  • Kim, Kwang-Hoon;Woo, Sung-Gwan;Son, Kwon;Park, Jeong-Kil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.678-684
    • /
    • 2008
  • A general treatment is to restore abfraction lesions with dental filler materials to reduce stress concentration. A material should be selected from various dental products based on long term experiences of dentist or personal preference concerning filler methods. A quantitative criterion is necessary to make an evaluation of the results as dentists decide treatment methods and dental materials relying on their clinical experiences. The purpose of this study is to find an optimal restoration method and material for noncarious cervical lesions using the finite element method. An objective function was defined to minimize the sum of tension or compression stress. Trial-and-error and approximation were used to find an optimal restoration method. An optimal solution was to fill TetricFlow inside the lesion and Z100 in the remaining region. The most desirable thickness ratio of the two filler materials was 0.125 with trial-and-error and it was similar to the results of approximation, 0.121 and 0.132.

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

  • Jeon, Jin-Hun;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.468-473
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by $10^{\circ}-20^{\circ}$ and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (${\alpha}=.05$). RESULTS. Precision discrepancies for the canine, premolar, and molar were $3.7{\mu}m$, $3.2{\mu}m$, and $7.3{\mu}m$, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were $6.2{\mu}m$, $11.2{\mu}m$, and $21.8{\mu}m$, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

Dental age estimation using the pulp-to-tooth ratio in canines by neural networks

  • Farhadian, Maryam;Salemi, Fatemeh;Saati, Samira;Nafisi, Nika
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.19-26
    • /
    • 2019
  • Purpose: It has been proposed that using new prediction methods, such as neural networks based on dental data, could improve age estimation. This study aimed to assess the possibility of exploiting neural networks for estimating age by means of the pulp-to-tooth ratio in canines as a non-destructive, non-expensive, and accurate method. In addition, the predictive performance of neural networks was compared with that of a linear regression model. Materials and Methods: Three hundred subjects whose age ranged from 14 to 60 years and were well distributed among various age groups were included in the study. Two statistical software programs, SPSS 21 (IBM Corp., Armonk, NY, USA) and R, were used for statistical analyses. Results: The results indicated that the neural network model generally performed better than the regression model for estimation of age with pulp-to-tooth ratio data. The prediction errors of the developed neural network model were acceptable, with a root mean square error (RMSE) of 4.40 years and a mean absolute error (MAE) of 4.12 years for the unseen dataset. The prediction errors of the regression model were higher than those of the neural network, with an RMSE of 10.26 years and a MAE of 8.17 years for the test dataset. Conclusion: The neural network method showed relatively acceptable performance, with an MAE of 4.12 years. The application of neural networks creates new opportunities to obtain more accurate estimations of age in forensic research.