• Title/Summary/Keyword: Dental effects

Search Result 2,460, Processing Time 0.032 seconds

Cerebral Activity by Motor Task in Welders Exposed to Manganese through fMRI (fMRI를 이용한 망간 노출 용접공의 운동수행에 따른 뇌 활성도 평가)

  • Choi, Jae-Ho;Jang, Bong-Ki;Lee, Jong-Wha;Hong, Eun-Ju;Lee, Myeong-Ju;Ji, Dong-Ha
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.102-112
    • /
    • 2011
  • Objectives: The purpose of this study is to analyze the effects of chronic exposure by welders to manganese (Mn) through an analysis of the degree of brain activity in different activities such as cognition and motor activities using the neuroimaging technique of functional magnetic resonance imaging (fMRI). The neurotoxic effect that Mn has on the brain was examined as well as changes in the neuro-network in motor areas, and the usefulness of fMRI was evaluated as a tool to determine changes in brain function from occupational exposure to Mn. Methods: A survey was carried out from July 2010 to October 2010 targeting by means of a questionnaire 160 workers from the shipbuilding and other manufacturing industries. Among them, 14 welders with more than ten years of job-related exposure to Mn were recruited on a voluntary basis as an exposure group, and 13 workers from other manufacturing industries with corresponding gender and age were recruited as a control group. A questionnaire survey, a blood test, and an fMRI test were carried out with the study group as target. Results: Of 27 fMRI targets, blood Mn concentration of the exposure group was significantly higher than that of the control group (p<0.001), and Pallidal Index (PI) of the welder group was also significantly higher than that of the control group (p<0.001). As a result of the survey, the score of the exposure group in self-awareness of abnormal nerve symptoms and abnormal musculoskeletal symptoms was higher than those of the control group, and there was a significant difference between the two groups (p<0.05, respectively). In the correlation between PI and the results of blood tests, the correlation coefficient with blood Mn concentration was 0.893, revealing a significant amount of correlation (p<0.001). As for brain activity area within the control group, the right and the left areas of the superior frontal cortex showed significant activity, and the right area of superior parietal cortex, the left area of occipital cortex and cerebellum showed significant activity. Unlike the control group, the exposure group showed significant activity selectively on the right area of premotor cortex, at the center of supplementary motor area, and on the left side of superior temporal cortex. In the comparison of brain activity areas between the two groups, the exposure group showed a significantly higher activation state than did the control group in such areas as the right and the left superior parietal cortex, superior temporal cortex, and cerebellum including superior frontal cortex and the right area of premotor cortex. However, in nowhere did the control group show a more activated area than did the exposure group. Conclusions: Chronic exposure to Mn increased brain activity during implementation of hand motor tasks. In an identical task, activation increased in the premotor cortex, superior temporal cortex, and supplementary motor area. It was also discovered that brain activity increase in the frontal area and occipital area was more pronounced in the exposure group than in the control group. This result suggests that chronic exposure to Mn in the work environment affects brain activation neuro-networks.

In Vitro Evaluation of Shear Bond Strengths of Zirconia Cerami with Various Types of Cement after Thermocycling on Bovine Dentin Surface (지르코니아 표면 처리와 시멘트 종류에 따른 치면과의 전단 결합 강도 비교 연구)

  • Cho, Soo-Hyun;Cho, In-Ho;Lee, Jong-Hyuk;Nam, Ki-Young;Kim, Jong-Bae;Hwang, Sang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.249-257
    • /
    • 2007
  • State of problem : The use of zirconium oxide all-ceramic material provides several advantages, including a high flexural strength(>1000MPa) and desirable optical properties, such as shading adaptation to the basic shades and a reduction in the layer thickness. Along with the strength of the materials, the cementation technique is also important to the clinical success of a restoration. Nevertheless, little information is available on the effect of different surface treatments on the bonding of zirconium high-crystalline ceramics and resin luting agents. Purpose : The aim of this study was to test the effects of surface treatments of zirconium on shear bond strengths between bovine teeth and a zirconia ceramic and evaluate differences among cements Material and methods : 54 sound bovine teeth extracted within a 1 months, were used. They were frozen in distilled water. These were rinsed by tap water to confirm that no granulation tissues have left. These were kept refrigerated at $4^{\circ}C$ until tested. Each tooth was placed horizontally at a plastic cylinder (diameter 20mm), and embedded in epoxy resin. Teeth were sectioned with diamond burs to expose dentin and grinded with #600 silicon carbide paper. To make sure there was no enamel left, each was observed under an optical microscope. 54 prefabricated zirconium oxide ceramic copings(Lava, 3M ESPE, USA) were assigned into 3 groups ; control, airborne-abraded with $110{\mu}m$ $Al_2O_3$ and scratched with diamond burs at 4 directions. They were cemented with a seating force of 10 ㎏ per tooth, using resin luting cement(Panavia $F^{(R)}$), resin cement(Superbond $C&B^{(R)}$), and resin modified GI cement(Rely X $Luting^{(R)}$). Those were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 5000 cycles with a 30 second dwell time, and then shear bond strength was determined in a universal test machine(Model 4200, Instron Co., Canton, USA). The crosshead speed was 1 mm/min. The result was analyzed with one-way analysis of variance(ANOVA) and the Tukey test at a significance level of P<0.05. Results : Superbond $C&B^{(R)}$ at scratching with diamond burs showed the highest shear bond strength than others (p<.05). For Panavia $F^{(R)}$, groups of scratching and sandblasting showed significantly higher shear bond strength than control group(p<.05). For Rely X $Luting^{(R)}$, only between scratching & control group, significantly different shear bond strength was observed(p<.05). Conclusion : Within the limitation of this study, Superbond $C&B^{(R)}$ showed clinically acceptable shear bond between bovine teeth & zirconia ceramics regardless of surface treatments. For the surface treatment, scratching increased shear bond strength. Increase of shear bond strength by sandblasting with $110{\mu}m$ $Al_2O_3$ was not statistically different.

A STUDY ON PROFILE CHANGE OF SKELETAL CLASS III MALOCCLUSION PATIENTS AFTER WEARING PROTRACTION HEAD GEAR (골격성 제III급 부정교합 환자에서 상악골 전방견인장치 사용후 측모 변화에 대한 연구)

  • Lim, Joong-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.375-401
    • /
    • 1995
  • Cause of skeletal Class III malocclusion in growing patients can be classified into maxillary deficiency, mandibular overgrowth, and combination of the two. Use of Protraction Head Gear(P.H.G.) has been recommended for treatment of growing Class III malocclusion patients, for it results in forward & downward movement of maxilla and backward & downward rotation of mandible. Numerous animal experiments were performed and clinical study data have been reported ; nevertheless, studies on soft tissue profile change and comparison of treatment effects among the patients who had undergone treatment are considered to be somewhat insufficient. The author selected 93 patients, who had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with P.H.G. ; the sample group was divided according to sex, treatment beginning age, palatal suture opening(intraoral appliance), and facial growth pattern. For each group, changing patterns of hard and soft tissue profile observed, and comparision with 20 normal group(Angle's Class I) patients of statistical significance in amount of growth and treatment of hard and soft tissue was done. The following results were obtained. 1. Skeletal, dental, and soft tissue measurements indicated that more growth changes was induced in the sample group that used P.H.G. compared to the growth amount of normal group. 2. No statistical significance was observed in the amounts of maxillary forward movement and mandibular backward & downward rotation depending on treatment beginning age in both sex group. 3. R.P.E. showed more significant maxillary forward movement and less protrusion of upper incisor than La-Li. 4. There was no statistical significance in the amount of maxillary forward movement depending on facial growth pattern. On the other hand, measurements indicating mandibular downward & backward rotation indicated greater change in counterclockwise growth pattern group than the clockwise. 5. Changes in upper and lower lip thicknesses showed a close relationship with positional changes in underlying bone tissue and upper and lower teeth, and upper lip height and nasolabial angle increased and mentolabial angle decreased.

  • PDF

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

Effects of SLA surface treated with NaOH on surface characteristics and response of osteoblast-like cell (염기처리한 SLA 표면이 표면 특성 및 골모유사세포의 반응에 미치는 영향)

  • Park, Jin-Chul;Kim, Joo-Hyeun;Kang, Eun-Sook;Ryu, Jae-Jun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.211-221
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate the surface characteristics and response of osteoblast-like cell at SLA surface treated with NaOH. Materials and methods: Three kinds of specimens were fabricated for the experiment groups. Control group was a machined surface, SLA group was a conventionally SLA treated surface, and SLA/NaOH gorup was SLA surface treated with NaOH. To evaluate the surface characteristics, the surface elemental composition (XPS), surface roughness and surface contact angle were evaluated in each group. And the cytotoxicity, cell adhesion, cell proliferation and ATP activity of osteoblast-like cells (MG-63 cells) were compared in each group for evaluatation of the cell responses. Statistical comparisons between groups were carried out via one-way ANOVA using the SPSS software (SPSS Inc., Chicago, USA), and then performed multiple comparisons. The differences were considered statistically significant at P<.05. Results: SLA surface treated with NaOH (SLA / NaOH group) was changed to hydrophilic surface. All groups did not show the cytotoxicity to the MG-63. In cell adhesion studies, SLA / NaOH group showed the higher degree of adhesion than anothers (P<.05), Up to 7 days of incubation, the proliferation was showed the increasing tendency in all groups but SLA / NaOH group showed the highest cell proliferation between the three groups (P<.05). At 7 days of incubation, there was no difference in ALP activities between the three groups, but at 14 days, SLA / NaOH group showed significant increase in ALP activities (P<.05). Conclusion: In this study, SLA surface treated with NaOH promoted cell adhesion, proliferation and differentiation. It means that SLA/NaOH group is possible to promote osseointegration of implants.

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.

THE EFFECT OF DISTAL MOVEMENT OF UPPER MOLAR USING THE PENDULUM APPLIANCE (Pendulum 장치의 상악대구치의 원심이동에 대한 효과)

  • Lee, Chang-Seop;Kim, Jae-Gwang;Kang, Dug-Il;Song, Kwang-Chul;Jung, Hyun-Ku;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.488-495
    • /
    • 2001
  • Treatment of class II malocclusions require distalization of maxillary molars into class I relationship. Intraarch distal molar movement techniques have recently assumed an important role in young patients. In this study, the dental and skeletal effects of the pendulum appliance were evaluated by means of cephalometric radiographs. The samples were consisted of 19 patients: 11 females and 8 males, mean age $11.68{\pm}1.52$ years. Measurements were obtained from cephalometric prior to and the day of removal of the pendulum appliance. Treatment changes were analyzed. The following results were obtain. 1. The pendulum appliance produced $2.94{\pm}1.54mm$ distal molar movement with a mean intrusion of $1.17{\pm}0.97mm$, mean period $18.13{\pm}7.95$ weeks. 2. The anchor tooth was $1.34{\pm}1.40mm$ forward movement and $0.48{\pm}0.99mm$ extrusion, and labial tilting of incisors. 3. The angle between palatal plane and mandibular plane increased significantly. 4. There was no significant difference in according to 2nd molar position. 5. Total movement was consisted of 74% distal movement of 1st molar and 26% forward movement of the anchor tooth.

  • PDF

A HISTOPATHOLOGIC STUDY ON THE PULPAL RESPONSE TO DEMINERALIZED FREEZE-DRIED BONE IN DOGS (탈회냉동건조골에 대한 성견의 치수조직반응에 관한 연구)

  • Jung, Moon-Yong;Lee, Chang-Seop;Park, Joo-Chul;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.318-332
    • /
    • 2000
  • The purpose of this study was to investigate the effects of demineralized freeze-dried bone (DFDB) on mechanically exposed pulp of dog by evaluating the pulpal inflammation and healing process, formation of dental hard tissue, and structural changes of fibroblasts of the remaining pulp tissue. Teeth of 4 dogs, weighing 10kg, were used in this study. Class V cavities were prepared followed by exposed the pulp tissue mechanically by sterilized round bur. In control group, exposed pulps were capped with calcium hydroxide paste followed by sealed with IRM. In experimental groups, the exposed pulps of one group were capped with the collagen and those of the other group were capped with DFDB. All cavities were sealed with same manor as control group. The animals were sacrificed at the intervals of 3, 7, 14, and 28 days for histopathlogic evaluation. The specimens were observed by the light microscope and trans-electron microscope. The results were as follows: 1. Pulp necrosis was not observed in all groups. Inflammatory response was disappeared from 1 week in control group and group 2. But it was not disappeared until 2 weeks and also irregular arrangement of odontoblasts was showed at the lateral walls of root canal just beneath the amputated site of the pulp in group 1. 2. Dentinal bridge was formed incompletely at 2 weeks but it was formed completely at 4 weeks in control group. Odontoid tissue was also found in control group at 4 weeks from treatment. Amputated site of pulp was encapsulated with fibrous tissue and odontoblast and dentinal bridge was not found in group 1. Preodontoid tissue and reparative dentin which were formed by odontoblast differentiated around DFDB were found, but dentinal bridge was not found in group 2. 3. Cell with large basophillic-stained nuclei infiltrated to amputated site and DFDB at 1 week from treatment in control group and group 2. They were found more in group 2 than in control group. Odontoblasts arranged more regularly and reparative dentin was found more as time elapsed. 4. Dentin-formative odontoblasts which showed ultramicrostructure of cytoplasm with polarized nucleus, rEM, Golgi complex, secretory granules, secretion of organic matrix in control of group and group 2. In regards to above results, the demineralized freeze-dried bone(DFDB) induce odontoblastic differentiation and further come up to the dentin formation in amputated pulp.

  • PDF

EFFECTS OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACES ON BOND STRENGTH (산 표면처리후 상아질과 법랑질 표면의 습윤이 결합강도에 미치는 영향)

  • Lee, Kwang-Won;Park, Soo-Joung;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.328-341
    • /
    • 1995
  • I. Shear Bond Strength to Air-dried and Remoistened Dentin.. The effect of air-drying and remoistening of acid-conditioned dentin before priming with the primer of All-Bond 2(BISCO. INC., U. S. A.) on shear bond strength(SBS) was investigated. Ninty freshly extracted sound human molars were divided at random into 9 groups of 10 teeth each. SBSs were meaured for acid-conditioned and non-conditioned dentin to which the primer and bonding agent of All-Bond 2 and composite resin(Z-100, 3M Dental Products, U. S. A.) were applied. The following values(Mean${\pm}$ SD, MPa) were obtained for the groups conditioned with 10% phosphoric acid for 15 seconds: Group l(blot dried) $6.7{\pm}4.1$ ; Group 2(10 seconds dried) $16.1{\pm}5.3$ ; Group 3(20 seconds dried) $15.4{\pm}4.8$ ; Group 4(30 seconds dried) $15.2{\pm}6.3$ ; Group 5(10 seconds dried/remoistened) $26.4{\pm}2.6$ ; Group 6(20 seconds dired/remositened) $22.2{\pm}2.7$ ; Group 7(30 seconds dried/remoistened) $21.5{\pm}4.1$. For the non-conditioned groups the values were: Group 8 (blot dried) $13.3{\pm}2.6$ ; Group 9(10 seconds dried) $12.9{\pm}3.5$. The data were analyzed using ANOVA. In the acid-conditioned groups, mean values of SBS for the air-dried specimens(Grps. 2, 3 and 4) and the 20 and 30 seconds dried/remoistened specimens (Grps. 6 and 7) were significantly lower than that of blot dried specimens.(p<0.05) The value for 10 seconds dried/remoistened specimens (Grp. 5), however, was not statistically different compared to that of blot dried specimens.(p>0.05) In the non-conditined groups, there was no statistical difference between blot dried and 10 seconds dried specimens.(p>0.05) The results suggest that the acid-conditioned dentin surface is more vulnerable to dentin bonding when it is air-dried or even remoistened after long period of drying. II. Shear bond stengh to the moistened and primed enamel. The effect of moistening and priming of enamel compared to the air-drying of enamel on the shear bond strength of enamel bonding agent was investigated. The experiment was divided into 4 groups each containing 10 caries-free maxillary incisor teeth. Shear bond strength values were measured for the primed and non-primed enamel to which All-Bond 2 and Z-100 were applied. The following values(MPa) were obtained for the primed groups pretreated with 32 % phosphoric acid for 15 seconds. : Group 1 (10 seconds dried) $29.8{\pm}2.2$ ; Group 2(moistened) $26.8{\pm}5.4$. For the non-primed groups the values were: Group 3(10 seconds dried/primed) $27.6{\pm}5.0$ ; Group 4(mostened/primed) $28.2{\pm}3.5$. The data were subjected to statistical analysis using ANOVA. The results showed that mean shear bond strengths among the experimental groups were not statistically different. (p>0.05) Conclusively, It is suggested that the bonding ability to enamel is not decreased by the moistening and priming of the enamel.

  • PDF

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.