• 제목/요약/키워드: Dental digital impression

검색결과 100건 처리시간 0.029초

한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구 (THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS)

  • 김형섭;신상완
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.

알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석 (Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions)

  • 주용훈;이진한
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.316-328
    • /
    • 2015
  • 목적: 보관 조건과 석고 주입 시간에 따라 알지네이트 인상체로부터 제작된 모형의 정확성을 알아보고자 하였다. 연구 재료 및 방법: 채득된 알지네이트 인상체는 습도가 유지되는 항습조에 보관하는 것과 진료실 내의 공기 중에 노출되는 상태로 보관 조건을 달리하였다. 보관 조건에 따라 각각 즉시, 채득된 후 10분, 30분, 180분, 360분으로 나누어 보관한 후에 석고 모형을 제작하였다. 제작된 석고 모형을 3D 레이저 스캐너로 삼차원 디지털 모형을 구성하였고 구성된 디지털 모형의 참고점에서 거리를 측정하여 변형률을 비교하였다. 또한 각 실험군의 삼차원 디지털 평균 모형을 제작한 후 중첩을 시행함으로써 표면 변위가 발생한 부위와 크기를 확인하였다. 결과: 인상 채득 즉시 제작한 모형의 변형률이 가장 작게 나타났고, 공기 중에 보관한 인상체보다 항습조에 보관한 인상체의 변형률이 작게 나타났다. 석고 주입 시간이 증가함에 따라서 변형률도 증가하였으며, 석고 주입 시간이 180분을 지나면 보관 조건에 관계없이 대구치 부위에서 변형률과 표면 변위가 증가한다. 결론: 알지네이트 인상체로부터 제작된 모형의 정확성을 위해서는 인상 채득 후, 즉시 모형을 제작해야 한다. 보관이 필요한 경우에는 100% 상대습도가 유지되는 항습조를 이용하고, 보관 시간은 180분을 넘지 않도록 해야 정확한 모형을 얻을 수 있다.

치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구 (A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems)

  • 정창섭;박종경
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제46권3호
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례 (Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report)

  • 임현정;김명주;권호범;임영준
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.299-306
    • /
    • 2017
  • 본 증례는 완전한 디지털 workflow로 단일 치아 임플란트 지지형 보철물을 즉시 부하하여 수복한 증례이다. 하악 제1대 구치 상실로 내원한 환자로, 구강 스캐너로 구내 디지털 인상채득 후, CT데이터와 디지털 스캔 데이터를 통해 제작한 수술용 가이드를 이용하여 임플란트를 식립하였다. 술 후 1주일 후, 맞춤형 지대주와 임시치아를 체결하여 즉시부하 하였다. 술 후 8주 후 지대주 레벨에서 구강스캐너를 이용하여 디지털 인상채득 후, 술 후 3개월에 지르코니아 최종 보철물을 장착하였다. 본 증례는 환자의 만족도 및 정확성 면에서 만족할 만한 결과를 나타내었으며, 완전한 디지털 과정을 통한 수복 결과 정확성, 심미성, 기능성 면에서 만족할 만한 결과를 나타내었기에 보고하는 바이다.

디지털 아트를 위한 기다림 - 디지털 대 아날로그 (Waiting for Digital Art - digital vs analogue)

  • 신준혁
    • 대한심미치과학회지
    • /
    • 제22권1호
    • /
    • pp.22-29
    • /
    • 2013
  • 일반적으로 심미 보철을 진행하기 위해서는 초진 시부터 카메라를 사용해서 최종 보철물을 고려하며 여러 가지 분석을 한다. 이 부분에서 많은 치의들이 디지털카메라를 사용하고 있는 현실을 볼 때, 우리는 이미 digital impression을 시작하고 있는 것이 아닐까 생각한다. 최근 세계적인 photographer들도 필름카메라에서 디지털카메라로 넘어오는 추세가 많아지고 있는 것처럼 심미 치과학에서도 CAD/CAM은 향후 우리가 추구하고자 하는 심미 영역에서의 또 한가지 방향성을 제시해 줄 수 있지 않을까 하는 생각이 든다. 흔히 디지털이라고 하면 편의성, 경제성 등을 먼저 떠올리는 경향이 있다. 그러나 치과 임상적 관점에서 기존의 analog방식을 존중하며 CAD/CAM system이 가지는 그 특수성과 우수성을 고민하고 이를 개선, 발전시키는 것 또한 중요하다고 생각된다. 다만 아쉬운 것은 CAD/CAM 장치와 소재가 급격히 발전하는 이유로 인하여 reference, follow-up이 어려운 경우가 많다. 이에 digital은 변화하는 속도가 굉장히 빠르기 때문에, 여러 가지 소재와 장치들을 접해보고 경험해보면서 그에 맞게끔 발맞춰 적용해 볼 수밖에는 없지만 임상에 적용하여 보다 좋은 결과 얻기 위해서는 전통적인 방식이 기본바탕이 된 상태에서 이루어져야 한다는 점을 강조하고 싶다. 본 연구에서는 심미적 관점에서 전통적인 방식과 CAD/CAM과의 조화 통해서 어떤 접근을 할 수 있는지에 대해서 살펴보고자 한다. 그리고 CAD/CAM 보철이 'Digital art' 영역에 한 축의 역할을 할 수 있기를 기다리고 열망한다.

구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례 (Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique)

  • 홍용신;박은진;김선종;김명래;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.67-73
    • /
    • 2012
  • 최근 디지털 인상채득 시스템이 개발되면서 이를 기존의 CAD/CAM 시스템과 접목한 인레이, 온레이, 크라운이나 간단한 계속가공의치 등의 고정성 보철물의 제작이 활발히 소개되고 있다. 그러나 임플란트 보철에서는 주로 기존의 아날로그식 인상채득 후 이를 스캔하여 제작하는 방법이 사용되어 왔으나, 구강 내 디지털 스캔한 데이터를 이용하여 나사형 보철물을 제작하는 술식은 아직 활발히 이루어지지 않았다. 이에 본 증례보고에서는 6명의 환자를 대상으로 구강 내 스캐너인 iTero를 사용하여 디지털 스캔을시행한후그중다섯명은맞춤형지대주와 시멘트 합착 후 나사형 임플란트 보철물(screw-retained implant prosthesis after cementation, or SCRP)을 제작하였고, 임상적으로 기능과 심미적인 측면으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

디지털 역량이 구강스캐너의 스캔 시간 및 스캔 오차에 미치는 영향 (Effect of digital competence on scan time and scan error in intraoral scanning)

  • Yun-Woo Kim;Do-Seon Lim;Hee-Jung Lim;Im-Hee Jung
    • 한국치위생학회지
    • /
    • 제24권4호
    • /
    • pp.271-280
    • /
    • 2024
  • 연구목적: 본 연구는 치과위생사 및 치위생(학)과 학생의 디지털 역량이 구강스캔 시간과 오차에 영향을 미칠 수 있는지를 확인하고자 시행되었다. 연구방법: 구강스캐너 사용 경험이 없는 치과위생사 및 치위생(학)과 학생을 대상으로 디지털 역량에 대한 설문 조사를 시행하였다. 동일한 대상자들에게 구강스캐너 사용법을 교육한 후, 구강 스캔을 3회 시행시켰고 이때 각 회차별 스캔 시간을 측정하였다. 이후, 3D 분석 프로그램을 이용, 모델스캐너로 채득한 기준데이터와 구강스캐너로 앞서 채득한 개별데이터를 중첩 분석하여 스캔오차를 확인하였다. 연구결과: 연령이 낮을수록 디지털 역량이 높고 스캔 시간이 적게 소요되었고, 디지털 역량 수준이 높은 그룹에서 스캔 시간이 짧았으며, 통계적으로 유의하였다. 세부 역량 중에서는 디지털 기술과 디지털 지식 역량 점수가 1점 증가 시, 스캔 시간이 각각 3.73분, 3.98분 감소하였다(p<0.05). 반면, 스캔 오차는 디지털 역량의 영향을 받지 않았다. 결론: 구강스캐너 연구 및 교육 시행 시, 연령과 디지털 역량을 고려해야 할 것이며, 추후 연구에서 치과 영역 맞춤형 디지털 역량 평가 도구 개발을 제안한다.