• 제목/요약/키워드: Dental crowns

검색결과 343건 처리시간 0.031초

A morphometric study on stainless steel crowns of the primary first molar using a three dimensional scanner

  • Lee, Jihyun;Shin, Teo Jeon;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hyun, Hong-Keun
    • 대한치과의사협회지
    • /
    • 제54권6호
    • /
    • pp.414-428
    • /
    • 2016
  • Objectives: The aim of this study was to assess the morphologic characteristics of two types of stainless steel crowns (SSCs) for the first primary molar using a 3D scanner. Study design: Two types of SSCs, KIDS CROWN (KC) and 3M ESPE ND-96 (ND), for the first primary molars were scanned using a 3D scanner. The mesiodistal and buccolingual diameters at the height of the contour and the cervical margin, occlusocervical diameters on the mesial, distal, buccal, and lingual aspects were measured, and the crown shape ratio, the smooth surface crown height ratio, and the cervical convergence were calculated. Results: In the crown shape ratio of the mandibular SSC, KC was larger buccolingually compared with ND. In the smooth surface crown height ratio, ND was larger than KC in all of the maxilla and mesial, distal, and lingual aspects of the mandible. ND was more convergent to the cervical mesiodistally and buccolingually compared with KC. Conclusion: In the superimposed images of the maxillary SSC, the mesiolingual and distolingual line angles of KC were more prominent compared with ND. In the mandible, ND demonstrated higher cusps and more obvious buccal developmental lobes than KC. ND showed a larger cervical undercut than KC.

  • PDF

3차원 스캐너를 이용한 대구치용 기성금속관의 형태에 관한 계측학적 연구 (A Morphometric Study of the Stainless Steel Permanent Molar Crown with Three-Dimensional Scanner)

  • 신종현;이형직;정태성;김신;김지연
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.287-300
    • /
    • 2018
  • 본 연구의 목적은 3차원 스캐너를 이용하여 현재 시판중인 두 종류의 대구치용 기성금속관의 형태적 특성을 비교하는 것이며, 또한 crimping 후의 치경부측 형태 변화를 분석 후 비교하는 것이다. 3차원 스캐너를 이용하여 상, 하악 대구치용 기성금속관인 PO-96과 PERMACROWN의 크기, crown index, 치경부 수렴도를 계측하였다. 이후 기성금속관들은 crimping을 통하여 치경부 형태를 조정하였고 3차원 스캐너를 통해 다시 스캔을 시행한 후 형태적 변화를 분석하였다. 상악 기성금속관의 폭경은 PERMACROWN이 PO-96에 비해 협설로 더 컸고 근원심으로는 더 작았으며, 치경부의 근원심 형태는 더 볼록하였다. 하악에서는 PERMACROWN이 PO-96에 비해 폭경은 협설로 작고 근원심으로 컸으며, 치경부의 근원심, 협설측 모두 더 볼록한 형태를 보였다. 그리고 두 기성금속관 모두 crimping 이후 치경부 변연 둘레는 감소하였다. 두 기성금속관은 크기, 형태, 치경부 수렴도에서 형태학적 차이를 보였다. 두 대구치용 기성금속관 모두 치경부 형태가 부여되어있지만 더 나은 변연적합을 위해서는 추가적인 crimping이 필요하다.

Orthopantomography에 의한 영구치 치관 석회화에 관한 연구 (A Study on Calcification of Crown of Rermanent Tooth by Orthopantomography)

  • 조사현
    • 대한치과의사협회지
    • /
    • 제11권12호
    • /
    • pp.787-799
    • /
    • 1973
  • Surveying the calcification degree of permanent tooth crown in 719 Korean children (Male 387, female 332) from 2 to 10 years old by orthopantomograph, the author got the following results. 1. Female was earlier than male in calcification of permanent teeth. 2. The results of the complete calcification of the permanent tooth crown were as follows. 3. The completion of calcification in the mandibular crown was seen earlier than that of the maxilla. 4. The order of calcification in permanent tooth crowns was as follows : 1 st molar, central incisor, lateral incisor, canine, 1st premolar, 2nd premolar, and 2nd molar. 5. The completion of calcification of the permanent crowns in Korean children was slightly retarded comparing with the Japanese and the American children.

  • PDF

임상가를 위한 특집 3 - Endocrown을 이용한 근관치료 후 수복 (Restoration after endodontic treatment with Endocrown)

  • 박정길
    • 대한치과의사협회지
    • /
    • 제50권7호
    • /
    • pp.384-393
    • /
    • 2012
  • Successful treatment of a badly broken down tooth with pulpal disease depends not only on good endodontic therapy, but also on good prosthetic reconstruction of the tooth after endodontic therapy is completed. The ideal treatment of endodontically treated teeth has been widely and controversially discussed. Endocrown is a restorative option for endodontically treated teeth. Endocrown design incorporates the core and short post into the crown as a single restoration. The preparation of endocrown consists of a circular equigingival butt-joint margin and central retention cavity of the entire pulp chamber instead of employing intraradicular posts. This design significantly increases the surface area of the preparation available for cementation. It is particularly useful in young patient teeth for long-term provisional restoration and in teeth with short clinical crowns. This technique represents a promising and conservative method for the treatment of endodontically treated teeth that require long-term protection and stability. Endocrown can be considered as a feasible alternative to full crowns or composite overlays for the restoration of non vital teeth.

첨가법에 의해 제작된 단관의 내면 적합도 분석 (Analysis of internal fitness of single crown fabricated by additive method)

  • 김원수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Purpose: The purpose of this study was to analysis the internal fitness of single crown fabricated by additive method technique. Methods: Study models were fabricated. Ten crowns were manufactured by additive method technique (AM group) and another ten crowns using conventional method were manufactured (CM group). The internal fitness of specimens were measured using silicone replica technique. Silicone replicas were sectioned one times (direction: from mesial to distal). The internal fitness were evaluated using by digital microscope. Statistical analyses were performed with independent samples t-test. (${\alpha}=0.05$). Results: Mean(SD) of all internal fitness were $92.1(20.0){\mu}m$ for AM group and $69.7(12.3){\mu}m$ for CM group. Two groups were statistically significant differences (p<0.001). Conclusion: All internal gaps of AM group were ranged within the clinical recommendation ($120{\ss}{\neq}$).

Clinical management of amelogenesis imperfecta in primary dentition

  • 김가영
    • 대한심미치과학회지
    • /
    • 제12권2호
    • /
    • pp.31-38
    • /
    • 2003
  • Amelogenesis imperfecta patients suffered common clinical problems of poor esthetics, teeth sensitivity, and loss of occlusal vertical dimension. Amelogenesis imperfecta is a group of inherited disorders primarily affecting dental enamel. Variants of amelogenesis imperfecta generally classified hypoplastic, hypocalcified, or hypomaturation types based on the primary enamel defects. The mildest problems were found in the pitted hypoplastic type whereas the most severe problems were encountered in the hypocalcified type amelogenesis imperfecta. Management stragies include composite resin veneer and jacket crowns for anterior teeth as well as steel crowns for posterior teeth. Knowledge of the clinical features and dental complications of each variants if amelogenesis impecta helps in the diagnosis of the condition and allows institution of early preventive measures. The objective of this paper is to provide a review of the current concepts of the wide spectrum of etiological factors involved in the pathogenesis of this significance clinical entity in the primary dentition.

  • PDF

The comparison of the accuracy of temporary crowns fabricated with several 3D printers and a milling machine

  • Junsik Lee;Sungwon Ju;Jihyung Kim;Sion Hwang;Jinsoo Ahn
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권2호
    • /
    • pp.72-79
    • /
    • 2023
  • PURPOSE. The purpose of this in vitro study was to compare the accuracy of various 3D printers and a milling machine. MATERIALS AND METHODS. The die model was designed using CAD (Autodesk Inventor 2018 sp3). The 30 ㎛ cement space was given to the die and the ideal crown of the mandibular left first molar was designed using CAD (ExoCAD). The crowns were produced using the milling machine (Imes-icore 250i) and the 3D printers (Zenith U, Zenith D, W11) and they were divided into four groups. In all groups, the interior of each crown was scanned (Identica blue) and superimposed (Geomagic Control X) with the previously designed die. The difference between the die and the actual crown was measured at specific points. The Kruskal-Wallis test, the Mann-Whitney test, and Bonferroni's method were performed with a statistical analysis software (P < .008 in inter-group comparison P < .001 in intra-group comparison). RESULTS. In all groups, the center of the occlusal area and the anti-rotational dimple area showed significantly greater difference and the marginal area showed the smallest difference comparatively. The mean value of the difference in each area and the sum of the differences were higher in order of W11, Imes-icore 250i, Zenith D, and Zenith U. CONCLUSION. The digital light processing (DLP) method shows higher accuracy compared to the sereolithography (SLA) method using the same resin material.

IPS Empress 도재관의 파절강도 : 상악 중절치에서 절단연 삭제량과 축면 경사도에 따른 영향 (Fracture strength of the IPS Empress crown :The effect of incisal reduction and axial inclination on upper central incisor)

  • 송병권;이해형;동진근
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.237-245
    • /
    • 2000
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal depth(2.0mm, 2.5mm, 3.0mm) and axial inclination($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper central incisor. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results were : 1. The fracture strength of the ceramic crown with 2.5mm depth and $8^{\circ}$ inclination was the highest(965N). Crowns of 2.0mm depth and $4^{\circ}$ inclination had the lowest strength(713N). There were no significant differences of the fracture strength by axial inclination in same incisal depth group. 2. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal depth. There had correlation between fracture strength and fractured surface area.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

Topical anesthesia for stainless steel crown tooth preparation in primary molars: a pilot study

  • Padminee, Krishnan;Hemalatha, R;Shankar, P;Senthil, D;Trophimus, Gnanabagyan J
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권4호
    • /
    • pp.241-250
    • /
    • 2020
  • Background: Placement of full-coverage restorations such as stainless steel crowns (SSCs) for pulpectomy treated primary molars is essential for successful outcomes. The tooth preparation process for SSCs can cause discomfort to gingival tissues since the crown should be seated 1 mm subgingivally. The purpose of this prospective trial was to compare the effectiveness of subgingival and transmucosal application of topical anesthetics on dental pain during SSC tooth preparation among 6- to 8-year-old children. Methods: A consecutive sample of 27 children, aged 6-8 years, who required an SSC after pulp therapy in primary molars were randomly divided into three groups. Group A received infiltration anesthesia before tooth preparation for SSC placement, whereas in Group B and C, only topical anesthesia was applied subgingivally and transmucosally. Wong-Bakers Faces pain rating scale (WBFPS) scores were recorded after tooth preparation. Faces, Legs, Activity, Cry and Consolability (FLACC) scores were evaluated by two blinded and calibrated investigators through video recordings of the patient during tooth preparation. Data were tabulated, and inter-group comparisons were performed using the Kruskal-Wallis and analysis of variance tests. Results: Out of the 27 participants, 48% were boys and 52% were girls, with an overall mean age of 6.83 years. Group A showed the least pain scores according to both the scales, followed by Group B and Group C. The pain intensity was statistically significant on both the pain scales with P = 0.003 for FLACC and P < 0.001 for WBFPS. Conclusion: Subgingival application of topical anesthesia reduced pain to a certain extent but not as effectively as infiltration anesthesia during SSC tooth preparation in primary molars. Transmucosal application of topical anesthesia did not reduce discomfort when compared to the other two interventions.