• Title/Summary/Keyword: Dental crown

Search Result 874, Processing Time 0.029 seconds

The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. (ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구)

  • Kim, Seok-Min;Park, Dong-Sung
    • The Journal of the Korean dental association
    • /
    • v.45 no.6 s.457
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

A COMPARATIVE STUDY ON RELIABILITY OF THE ROOT PARALLELISM OF THE POSTERIOR TEETH PROJECTED ON THE ORTHOPANTOMOGRAM WITH THE $45^{\circ}$ OBLIQUE CEPHALOGRAM (Orthopantomogram과 $45^{\circ}$ 측모두부 방사선 사진과의 구치부 치근평행도의 신뢰도에 관한 비교연구)

  • Min, Young-Gyu;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.359-374
    • /
    • 1993
  • At present, many orthodontists regard the root parallelism of the posterior teeth important not only in diagnosis and treatment planning but also for predicting posttreatment stability. To evaluate it, they usually refer to the orthopantomogram. At this study, 97 samples were collected from students of Yonsei University, who have well-proportioned face, Angle's class I canine & molar relationships and no crown axis deviation of the posterior teeth including canines. Reliability of the root parallelism observed from orthopantomogram was evaluated by comparison with $45^{\circ}$ oblique cephalogram. The results were as follows : 1. In comparing the differences between anglular measurements in $45^{\circ}$ oblique cephalogram & orthopantomogram with $5^{\circ}$, those to mandibular plane were significantly less than to occlusal plane in number of items which showed less differences than $5^{\circ}$. 2. Compared the root parallelisms in the orthopantomogram with those in $45^{\circ}$ oblique cephalogram with $1\%$ significance level, parallelism between upper canine & 1st premolar, lower canine & 1st premolar, lower 1st premolar & 2nd premolar, and lower right 2nd molar & 3rd molar showed statistically significant differences. 3. When the significance between the differences of the root parallelism between above two kinds of film and $5^{\circ}$ was verified by two sided paired t-test, more or less large difference was shown between lower right 2nd molar & 3rd molar, a little larger than $5^{\circ}$ between lower canine & 1st premolar, smaller at the rest of them. 4. In $45^{\circ}$ oblique cephalogram, lower canine & 1st premolar showed convergent root arrangements each other, while in orthopantomogram they were divergent each other. All the others except them showed convergency on the upper, divergency on the lower in both films.

  • PDF

Conservative Treatment Using Marsupialization for Cysts Occurring in the Jaw of Adolescents: A Case Report

  • Yun, Sun-Ung;Jung, Hai-Won;Cho, Byung-Yong;Choi, Byung-Joon;Lee, Baek-Soo;Kwon, Yong-Dae;Ohe, Joo-Young;Lee, Jung-Woo
    • Journal of Korean Dental Science
    • /
    • v.7 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Dentigerous cyst (DC) is an odontogenic cyst associated with the crown of an impacted, embedded, unerupted, or developing tooth. It is the second most common type of odontogenic cysts, accounting for 14% to 24% of all jaw cysts. Although these cysts occur more frequently during the second and third decades of life, they can also be found in children and adolescents in the mixed dentition stage. Treatment of the odontogenic cyst involves enucleation or marsupialization/decompression methods. The latter approach is preferred for larger cysts, and it is especially helpful in adolescent patients in conserving the unerupted permanent successors. The aim of treatment for DC is the complete elimination of pathology and maintenance of dentition with minimal surgical intervention. Recently defined criteria for the selection of treatment modality include the cyst size and location of the cyst, patient age, dentition involved, stage of root development, position of the tooth involved in the jaw, and relationship with the surrounding vital structure. Marsupialization or decompression technique has been advocated by several authors for treating DCs among young patients. In this conservative technique, the creation of an accessory cavity helps relieve intra-cystic pressure and accelerate the healing of cystic lesion. This technique has been successfully performed and is indicated for growing children and adolescents. Here, we report a large cyst lesion in the mandible treated by marsupialization for conservative management. In conclusion, successful reduction in size was achieved, and intraoperative complication could be prevented.

Clinical study of maxillofacial trauma of children (소아 구강악안면 영역의 외상에 관한 임상적 연구)

  • Kim, Hak-Ryeol;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.1
    • /
    • pp.43-52
    • /
    • 2010
  • Purpose: To research about maxillofacial traumatic injuries of children in aspects of gender difference, various incidence rates between age, trauma type, cause, monthly and daily incidence rate, type of tooth damage, gingival damage, soft tissue damage, and type of facial bone fracture. Materials and methods: Study group consisted of children under 15 years of age who visited Dental Hospital, School of Dentistry, Kyung Hee University from 2004/7/1 to 2007/6/30 with chief complaint of oral and maxillofacial traumatic injuries. 1,559 cases of traumatic injuries were studied from 1,556 (1,004 male, 552 female) children. Conclusion: 1. There were slightly more boys than girls, giving a male-to-female ratio of 1.82:1.0. The 1-3 year old boys and girls had the highest number of traumatic injuries. 2. Of the 1,556 patients, 68.63% had soft tissue injuries, 50.22% had periodontal injuries, 29.89% had teeth injuries, and 3.85% had maxillofacial bone fractures. 3. Falling down was the most common cause of injury in both sexes. 4. The months with the highest incidence rates were in order May (12.12%), June (11.74%), and October (11.13%). Most of the injuries occurred on weekends. 5. The most common tooth injury was uncomplicated crown fracture, and the most common periodontal injury was subluxation. The majority of traumatizes teeth were the upper central incisors. 6. The most common soft tissue injury was intraoral lacerations. 7. Mandibular fractures were most frequent in facial bone fractures; symphysis, condylar head, and angle fractures were most frequent in mandibular fractures; maxillary and nasal bone fractures were most frequent in midfacial bone fractures.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

Maxillary sinus augmentation with biphasic calcium phosphate(Osteon$^{(R)}$); A clinical and radiographic study (Original Article 1 - 합성골 이식재인 Osteon$^{(R)}$을 이용한 상악동 거상술-임상적, 방사선 계측학적 연구)

  • Cha, Jae-Kook;Jung, Ui-Won;Kim, Min-Soo;Um, Yoo-Jung;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chung, Sung-Min
    • The Journal of the Korean dental association
    • /
    • v.48 no.1
    • /
    • pp.45-55
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate 1 year cumulative survival rate of implants placed on augmented sinus using Osteon$^{(R)}$, bone graft material and to assess height of the grafted material radiographically. Material and Methods: 10 maxillary sinuses were augmented in 10 patients and 25 implant fixtures were installed simultaneously or after 6 months healing period. The height of the sinus graft material was measured using panoramic images immediately after augmentation and up to 19 months subsequently. Changes in the height of the sinus graft material were calculated with respect to implant length and original sinus wall height. Results: The cumulative survival rate was 100% in all 25 implants. Additionally, normal healing process without any complication was observed in all patients. The mean crown/Implant ratio was 1.25. The mean marginal bone loss was 0.95mm and the mean resorption rate of Osteon$^{(R)}$ was 0.05mm/month. The fastest resorption site of Osteon$^{(R)}$ is the first molar area. The grafted material was well maintained in sinus and decreased slightly over 1 year. Conclusion: In conclusion, It can be suggested that Osteon$^{(R)}$ may have predictable result when it was used as a grafting material for sinus floor augmentation.

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.