• Title/Summary/Keyword: Dental core

Search Result 262, Processing Time 0.026 seconds

Analysis of Dental Hygienist Job Recognition Using Text Mining

  • Kim, Bo-Ra;Ahn, Eunsuk;Hwang, Soo-Jeong;Jeong, Soon-Jeong;Kim, Sun-Mi;Han, Ji-Hyoung
    • Journal of dental hygiene science
    • /
    • v.21 no.1
    • /
    • pp.70-78
    • /
    • 2021
  • Background: The aim of this study was to analyze the public demand for information about the job of dental hygienists by mining text data collected from the online Q & A section on an Internet portal site. Methods: Text data were collected from inquiries that were posted on the Naver Q & A section from January 2003 to July 2020 using "dental hygienist job recognition," "role recognition," "medical assistance," and "scaling" as search keywords. Text mining techniques were used to identify significant Korean words and their frequency of occurrence. In addition, the association between words was analyzed. Results: A total of 10,753 Korean words related to the job of dental hygienists were extracted from the text data. "Chi-lyo (treatment)," "chigwa (dental clinic)," "ske-illing (scaling)," "itmom (gum)," and "chia (tooth)" were the five most frequently used words. The words were classified into the following areas of job of the dental hygienist: periodontal disease treatment and prevention, medical assistance, patient care and consultation, and others. Among these areas, the number of words related to medical assistance was the largest, with sixty-six association rules found between the words, and "chi-lyo," "chigwa," and "ske-illing" as core words. Conclusion: The public demand for information about the job of dental hygienists was mainly related to "chi-lyo," "chigwa," and "ske-illing" as core words, demonstrating that scaling is recognized by the public as the job of a dental hygienist. However, the high demand for information related to treatment and medical assistance in the context of dental hygienists indicates that the job of dental hygienists is recognized by the public as being more focused on medical assistance than preventive dental care that are provided with job autonomy.

Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

  • Rosa, Guillermo M.;Elizondo, Maria L.
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • Purpose: The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods: A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results: For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion: The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

A comparative analysis of competencies in American Dental Education Association and American Dental Hygiene Schools (미국치의학교육협의회(ADEA) 치과위생사 표준역량과 미국 치위생(학)과의 역량 비교분석)

  • Choi, Da-Som;Kim, Sook-Hyang;Kim, Jin-Soo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.547-553
    • /
    • 2015
  • Objectives: In this comparative analytic study the standard competency of American Dental Hygienists proposed by the America Dental Education Association was examined and compared with the competency of American school of entry-level to identify the competence required by domestic dental hygienists. Methods: Based on the standard competency presented by the America Dental Education Association the 109 schools which provide respective dental hygiene competency among 336 universities and colleges belonging to the entry-level were compared with each other, and the collected data were processed by SPSS 21.0. Results: The descriptive statistics upon overall competence were prepared and the results of survey revealed the highest average score of 7.53 for the Core competency. It was identified that there were statistically significant difference between two groups of the above(the top 25%) and below the average level(the 25% from the bottom) in all the competency. The competency of participation in local community and patients' care were appeared as significant variables affecting the core competency of dental hygienists with the 76.4% of explanatory power, and the model reveals the statistically significant results(p<0.001). Conclusions: Based on these results it was identified that the ethical, communication skill, self-development efforts, and capability of critical thinking and judgment were necessary competency for the dental hygienists. Further efforts to integrate and standardize the competency of domestic dental hygienists are thus needed and based on these integrated and standardized competencies the integrated curricula to cultivate domestic dental hygienists should be developed.

A study on the visible wave of transmittance pressable ceramic core (열가압성형도재 코어의 가시광선 투과율에 관한 연구)

  • Jung, In-Ho;Lee, Sang-Deok;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

A study on the transmittance due to thickness of zirconium core (지르코니아 코어의 두께에 따른 분광광도계 투과율에 관한 연구)

  • Jung, In-Ho;Park, Myung-Ja;Kim, Joo-Won
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.129-136
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the transmittance differences of zirconium core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 3 groups (0.6mm, 0.8mm, 1.0mm) which have each 12 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown.

Analysis of the Marginal and Internal Fit of Dental Zirconia Core Using Optical Coherence Tomography(OCT) (광간섭단층영상기를 이용한 치과용 지르코니아 코어의 적합도 분석)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.240-247
    • /
    • 2012
  • Marginal and internal fit is an important part of the longevity of dental restorations. The purpose of this study was to analysis the marginal and internal fit of zirconia core by dental CAD/CAM system using innovative and non-destructive methods such as optical coherence tomography(OCT) and compare with conventional method such as silicone replica technique(SRT). Ten dental stone models of abutment of maxillary right central incisal were manufactured and scanned. Ten zirconia cores were fabricated with commercial CAD/CAM system. To measure the marginal and internal fit of each sample, five point of fitness were measured using 2 different methods(OCT and SRT). Statistical analysis was performed using independent sample t-test(${\alpha}$=0.05). OCT and SRT groups were not significantly different(P>0.05). By this results, analysis the fitness of dental restorations using OCT were acceptable measuring method.

The Effect of Veneering Techniques on the Color Parameters of Y-TZP Based All Ceramic Restoration of Varying Ceramic Core Thickness (지르코니아 코어 두께에 따른 전부도재관의 상부도재 축성방법이 보철물 색조에 미치는 영향)

  • Huh, Sung-Yoon;Son, Ho-Jung;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • The aim of study was to compare the color parameters and mean color difference of porcelain specimens by different veneering technique in order to examine the effect of veneering technique on esthetics of yttria-stabilized tetragonal zirconia polycrystalline(Y-TZP) all ceramic restoration. Three groups of square-shaped core ceramic specimens(14mm in diameter and 0.3, 0.5, 0.7 mm) and two groups of veneering ceramic specimen were prepared for analysis. Color parameter($L^*,a^*,b^*$) and color difference of zirconia core squares and core-veneer specimens were measured with ShadeEye $NCC^{(R)}$ spectrophotometer, respectively. Mean color difference(${\Delta}E^*$)were calculated using color difference formula. Two-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}=0.05$). ${\Delta}E^*$ values were not significantly affected by core thickness and veneering porcelain(p=0.083). The color differences(${\Delta}E^*$) of core-veneer specimens with 0.5, 0.7 mm-A1,A2,A3.5 shade were mostly below 3.7 which was within the clinically acceptable range, while color differences between 0.3 mm-A1,A2 showed more than 3.7. All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Evaluation of the fracture resistance of all-ceramic zirconia posts by 3 different methods

  • Jeong, Seung-Mi;Chung, Chae-Heon;Kang, Dong-Wan;Ludwig, Klaus;Kern, Matthias;Huels, Alfons
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.757-764
    • /
    • 2000
  • Statement of the problem. All-ceramic post-and-core restorations offer a number of advantages compared with systems that use metal build-ups. In certain clinical cases, however, fractures at the joint between the post and core build-up have been reported. Purpose. The objective, therefore, is to improve the joint between the post and the core build-up. Material and methods. Three different methods were used to prepare all-ceramic post-and-core restorations; pressing IPS Empress core build-ups to CosmoPost zirconia posts, cement-ing IPS Empress core build-ups to CosmoPost zirconia posts and Celay-milling of zirconia blanks. A series of ten restorations was prepared for each of the three methods. The post-and-core complexes were tested to failure with the load applied perpendicular to the post axis. The load and deflection at fracture were recorded. Results. The highest breaking load and highest deflection were recorded for the cementing technique with values of 25.3 N and $394{\mu}m$, respectively, The corresponding values for the pressed core build-ups and the milled zirconia core build-ups were 22 N and $301{\mu}m$, and 13 N and $160{\mu}m$, respectively. All the differences are statistically significant (p=0.05). Regarding the load-dependence of the deflection, the cemented core build-ups again demonstrated the highest value with $15.5{\mu}m/N$. The difference in the values of $13.6{\mu}m/N\;and\;13{\mu}m/N$ recorded for the pressed-on and milled core build-ups, respectively, were statistically insignificant. Conclusion. In regard to the high fracture resistance of zirconia post, adhesive cementing the core build-up to the post offers a viable alternative to the conventional pressing technique. The elastic bond between the rigid high-strength zirconia post and the core build-up presents an additional advantage.

  • PDF

The Influence of Surface Treatments on Shear Bond Strength between Zirconia Core and Heat Press Ceramic Interface (지르코니아 코어의 표면처리방법이 열 가압 세라믹과의 전단결합강도에 미치는 영향)

  • Park, Hang-Min;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.23-30
    • /
    • 2009
  • All-ceramic restorations have gained acceptance among clinicians and patients because of their superior esthetics. Most all-ceramic systems have a 2-layer structure, using a weak veneering ceramic over a strong supporting core. often, failure of all-ceramic restorations occurs when the veneering ceramic fractures, exposing the core material. The purpose of this study was to compare the shear bond strength of heat press ceramic system (Zirpress) to zirconia core with various surface treatments. 10 metal cores and 50 zirconia cores were fabricated and divided into six groups according to surface treatment such as Zirliner application, aluminium oxide blasting, and 9.5% HF etching. Sixty specimens were prepared using Zirpress, veneered 8mm height and 3mm in diameter, over the zirconia cores (n=10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 1/min. Ultimate shear bond strength data were analyzed with One-way ANOVA and the Scheffe's test (p=.05). Within the limits of this study, the following conclusions were drawn: The mean shear bond strengths (MPa) were: 12.93 for $110{\mu}m$ aluminium oxide blasting/Rexillium III/IPS e.Max Zirpress; 14.92 for $50{\mu}m$ aluminium oxide blasting ${\pm}9.5%$ HF etching/Zirconis core/IPS e.Max Zirpress; 16.37 for $110{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 12.89 for $200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.30 for 9.5% HF etching/Zirconis core/IPS e.Max Zirpress; 19.55 for Zirliner/Zirconis core/IPS e.Max Zirpress. The mean shear bond strength for ZNTZH (Zirliner/Zirconis core) and ZNTEH (9.5% HF etching/Zirconis core) were significantly superior to MS110H ($110{\mu}$ aluminium oxide blasting/Rexillium III) and ZS200EH ($200{\mu}$ aluminium oxide blasting + 9.5% HF etching/Zirconis core) (p<0.05).

  • PDF

The Properties of Sintered Body by Using the Slip Casting Process with Remained Dental Zirconia Block after Machining (치과용 지르코니아 코어 가공후의 잔여물을 활용하여 주입성형법으로 제조한 소결체의 특성)

  • Kim, Sang-Su;Lee, Dong-Yoon;Seo, Jeong-Il;Bae, Won-Tae
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • Purpose: All ceramic crown, made from zirconia instead of metal for core material, is recognized the best esthetical prosthesis. Recently, high-priced zirconia blocks and expensive CAD/CAM machines come into use for making zirconia core. In this study, slip casting process is adapted to evaluate the possibility of the recycling the remained parts of zirconia block after machining. Methods: Remained zirconia blocks were reduced to powders with zirconia mortar, and screened with 180 mesh sieve. Passed powders were ball milled under various conditions to obtain the optimum zirconia slip for casting. Solid casting method was used for casting the specimens with plaster mold. Formed specimens were dried and biscuit fired at $1,000^{\circ}C$ for 1 hour. Biscuit fired specimens were finished with exact shape of square pillar. Finished specimens were fired from $1,200^{\circ}C$ to $1,550^{\circ}C$ at $50^{\circ}C$ intervals for 1 hour. Linear shrinkage, apparent porosity, water absorption, bulk density, and flexural strength were tested. Microstructures were observed by SEM. Results: Above examinations indicated that the optimum firing temperture was $1,500^{\circ}C$, and when fired at this temperature for 1 hour, apparent porosity was 0% and flexural strength was 680MPa. SEM photomicrographs showed uniform 200~300nm grain size, which is equal with microcture of sintered commercial zirconia block. when compare 24% linear shrinkage of cast specimen with 20% linear shrinkage of CAD/CAM machined block, it was estimated that the size controlling of cast core was not so difficult. Conclusion: According to the all of this experimental results, the cast zirconia core produced from the remained parts of zirconia block was possible to use for all ceramic denture.